background image

VR2

VR1

L.T.C

Mains Supply

FAN

+10V

Control

Ground

Tacho

Speed Control

FAN

VR2

VR1

L.T.C

Mains Supply

+10V

Control

Ground

Tacho

Speed Control

FAN

E

N

L

LTC FAN

M VALVE

S

W

DIGITAL

ROOMSTAT

BYPASS
  TUBE

1

2

3

4

5

6

7

8

9

E

N

L

VR2

VR1

L.T.C

Mains Supply

+10V

Control

Ground

Tacho

Speed Control

N ot e:  T he  e arth  l i nk is  d irec tl y
ab ove  t he  ne gat i ve  te rm i na l 
on  t he  E C  D C  f i lt er.  

FAN

E

N

L

S

W

DIGITAL

ROOMSTAT

BYPASS
  TUBE

1

2

3

4

5

6

7

8

9

M VALVE

LTC FAN

E

N

L

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
   
 
 
 
 
 
 
 
 
 
   
 

 Fig 3 

 
 
 
 
    
 

 
 

 

 
 

6

 

2. Fix the unit to the wall via suitable fixings. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3. Connect the heating system flow and return pipes to the heater pipe work. Pipe entry/ exit 
can be made through either the back of the unit or by using the Pipe Knockouts on the bottom 
of the unit (See Fig 3). Do not use soldered fittings to connect the heater pipe work as the heat 
generated may cause damage to internal wiring and components. 

 

We recommend the use of full-flow service valves. The valves should be accessible after 
completion of the installation. We also advise the fitting of an air vent at the highest point on 
either the flow or return pipe to remove any air trapped within the system. 
4. Open the full flow service valves (see above) and check for water leaks. Remove any 
trapped air from the unit via the built in bleed screws as shown in the diagram below. 
 

Note: Ensure the motorised valve is set to the Auto position. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5. Isolate the electrical supply   

245

66

176

660

274

A

Model

A

60

595

90

895

Electrical supply 
in this side

Pipe Centres

B

4

80

45

Fix to wall using 
suitable fixings

B

470
770

85

1

50

120

1195

1070

150

1495

1370

180

1795

1670

 

Caspian CL 60 
Wiring Diagram 

Caspian CL 90/ 120 
Wiring Diagram 

Summary of Contents for LST Caspian 60 Series

Page 1: ...ironment WEEE Registered Code WEE ED0093VW For Ireland Republic Northern contact MT Agencies on 00 353 1 864 3363 In light of our policy of continuous development Smith s Environmental Products Ltd reserve the right to alter specifications without prior notice Iss 5 8 OCT 17 Suitable for Low Level Installation Only Installation User Guide User Information This appliance can be used by children age...

Page 2: ... 2 Fault Finding 1 The fan does not run on any speed setting a Check the power supply is switched ON b Check the fuse in the fused spur c Check the wiring at the fused spur d Check thermostat is calling for heat e Check the central heating is switched ON and hot water flowing through system f Vent any trapped air from the system with the heating system turned OFF 2 No heat output a Vent any trappe...

Page 3: ...See Fig 3 Do not use soldered fittings to connect the heater pipe work as the heat generated may cause damage to internal wiring and components We recommend the use of full flow service valves The valves should be accessible after completion of the installation We also advise the fitting of an air vent at the highest point on either the flow or return pipe to remove any air trapped within the syst...

Page 4: ...lease ensure adequate flow through heater 7 Lift up and close front access panel ensure this is secure and locked in place with keys provided 8 Please leave this Installation User Guide with the user for future reference Heating see below Ensure the central heating system is ON Switch on the power supply to the unit Set the thermostat control if fitted to the desired temperature Providing the wate...

Page 5: ...s It is important to register within 7 days This will ensure you receive a prompt and efficient service if your product requires attention within the guarantee period If you do not register your product you will be required to produce a proof of purchase prior to receiving this service If you experience any problems with the use of your product please contact our after sales office on 01245 324560...

Page 6: ...survey the response will help us to serve your needs more effectively Please return by fax to 01245324422 Quality Control Manager Ron Brown ron brown smithsep co uk User Details User Name Mr Mrs Miss Ms Other Initials Surname Address Post Code Telephone Product Model installed e g Space Saver SS5 Room Installed e g Kitchen Your details will only be held by Smiths Environmental Products Ltd and use...

Reviews: