Understanding IP Ratings
THE FIRST DIGIT indicates the level of protection that the enclosure provides
against access to hazardous parts (e.g., electrical conductors, moving parts)
and the ingress of solid foreign objects.
THE SECOND DIGIT indicates protection of the equipment inside the enclosure
against harmful ingress of water.
LEVEL
OBJECT SIZE
PROTECTED AGAINST
EFFECTIVE AGAINST
0
No protection against contact and ingress of objects
1
>SO mm
Any large surface of the body, such as the back of a hand, but no protection against deliberate contact
with a body part
2
>12.5 mm
Fingers or similar objects
3
>2.Smm
Tools, thick wires, etc.
4
>1 mm
Most wires, screws, etc.
5
Dust Protected
Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the
satisfactory operation of the equipment; complete protection against contact.
6
Dust Tight
No ingress of dust; complete protection against contact
LEVEL
PROTECTED AGAINST
TESTING FOR
DETAILS
0
Not Protected
1
Dripping Water
Dripping water (vertically falling drops) shall have no
harmful effect.
Test duration: 10 minutes - Water equivalent
to 1mm rainfall per minute
2
Dripping Water
When Tilted
Up To 15°
Vertically dripping water shall have no harmful effect
when the enclosure is tilted at an angle up to 15° from its
normal position.
Test duration: 10 minutes - Water equivalent
to 3mm rainfall per minute
3
Spraying Water
Water falling as a spray at any angle up to 60° from the
vertical shall have no harmful effect.
Test duration: 5 min. - Water volume: 0.7
liters per minute - Pressure: 80- 100 kN/m2
4
Splashing Water
Water splashing against the enclosure from any direction
shall have no harmful effect.
Test duration: 5 min.- Water volume: 10 liters
per minute - Pressure: 80- 100 kN/m2
5
Water Jets
Water projected by a nozzle (6.3mm) against enclosure
from any direction shall have no harmful effects.
Test duration: at least 3 min. - Water volume:
12.5 liters per minute - Pressure: 30 kN/m2 at
distance of 3m
6
Powerful Water
Jets
Water projected in powerful jets (12.5mm nozzle) against
the enclosure from any direction shall have no harmful
effects.
Test duration: at least 3 minutes - Water vol-
ume: 100 litres per minute - Pressure:100 kN/
m2 at distance of 3m
7
Immersion
Up To 1m
Ingress of water in harmful quantity shall not be
possible when the enclosure is immersed in water
under defined conditions of pressure and time (up to
1m of submersion).
Test duration: 30 minutes Immersion at
depth of Im
8
Immersion
Beyond 1m
The equipment is suitable for continuous immersion in
water under conditions which shall be specified by the
manufacturer. Normally, this will mean that the equipment
is hermetically sealed. However, with certain types of
equipment, it can mean that the water can enter but only
in such a manner that it produces no harmful effects.
Test duration: continuous ummersion in
water.