background image

 

Clean up 

 

   

 

C A U T I O N

   

 

 

As with any type of sprayer, this unit will not function 
satisfactorily if the unit is not clean. If the product being 
sprayed is intended to cure or set up after application, the 
Sprayer must be cleaned and flushed after EACH use by 
using the appropriate fluids as recommended by the 
chemical/ compound manufacturer. Pump the cleaning 
agent through the sprayer until all traces of the previously 
sprayed material has been removed from the unit. Failure 
to clean the unit after using these types of materials will 
result in failure of the unit and loss of warranty coverage. 
 
DO NOT USE THE PUMP TO PURGE THE SPRAY 
HOSE. Running the Pump dry over 1 minute will destroy 
the gears and void the warranty. Disconnect the Hose on 
each end and drain manually using gravity.   

 
 

Chemical Compatibility

 

 
The magnetically coupled gear pump has no seals or 
gaskets in the fluid path and therefore will not leak. The 
only material coming in contact with the fluid being sprayed 
is 316 Stainless Steel, Ceramic and PEEK 
(Polyetheretherketone) Gears. 
 
The only solvents which will attack PEEK are concentrated 
nitric acid and sulphuric acids.  

 

   

 

C A U T I O N

   

 

 

IT IS YOUR RESPONSIBILITY TO ENSURE THAT THE 
MATERIAL YOU ARE SPRAYING IS COMPATIBLE 
WITH THE PUMPS COMPONENTS. 

 
 
 

Page 11 

   

 

C A U T I O N

   

 

 

 

  If the product being sprayed is intended to cure or 

set up after application, the Sprayer must be 
cleaned and flushed using the appropriate fluids as 
recommended by the chemical/compound 
manufacturer. Failure to clean the unit after using 
these types of materials will result in failure of the 
unit and loss of warranty coverage. 

 

  Attempting to spray liquids below the manufactures 

recommended temperatures may affect the sprayers 
ability to adequately perform. Low temperatures 
may affect your materials viscosity. 

 

  Do not submerge or expose to excessive moisture 

 

  Do not spray liquids with high solids (0ver 35%) or 

abrasive additives as this will destroy the pumps 
gears and will void the warranty. This Sprayer is 
intended for and was tested with Chemicals used for 
curing and sealing applications. If you are unsure of 
the suitability of the product you want to spray 
contact SMK at 515-202-0052 for assistance.   

 

 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 

Page 4 

Summary of Contents for P100AC

Page 1: ...ndustries Inc Operator s Safety and Service Manual Cordless Sprayer Model P100AC ALL CHEMICALS SMK Industries Inc 12839 Carpenter Trail Carlisle IA 50047 Phone 515 202 0052 Email john smksprayers comWeb www smksprayers com ...

Page 2: ...lt NiCad or Lithium Ion 18V battery SMK reserves the right to make changes to this manual without notice Table of Contents Safety Information 2 Introduction 2 Safety Precautions 3 4 Warranty 5 Proof of purchase 6 Specifications 6 Operation 7 Contents of carton 7 Assembly 8 9 Operating the sprayer 10 Clean up 11 Chemical compatibility 11 Troubleshooting 12 Maintenance 13 Service 13 Replacement part...

Page 3: ...observe may result in damage to the equipment and or severe bodily injury or death C A U T I O N GENERAL CAUTION Indicates information important to the proper operation of the equipment Failure to observe may result in damage to the equipment REFERENCES For details on safety rules and regulations in the United States contact your local Occupational Safety and Health Administration OSHA office Equi...

Page 4: ...d accessories attached When using the unit ensure that the sprayer discharge hose is securely attached Do not modify the unit Page 3 Trouble shooting SPRAYER WILL NOT START If battery is not properly seated and fully charged If On Off switch is in the off position If Speed Control is turned off counterclockwise SPRAYER WILL NOT PRIME If pickup tube or discharge hose is restricted If Spray tip or F...

Page 5: ...eel Ceramic and PEEK Polyetheretherketone Gears The only solvents which will attack PEEK are concentrated nitric acid and sulphuric acids C A U T I O N IT IS YOUR RESPONSIBILITY TO ENSURE THAT THE MATERIAL YOU ARE SPRAYING IS COMPATIBLE WITH THE PUMPS COMPONENTS Page 11 C A U T I O N If the product being sprayed is intended to cure or set up after application the Sprayer must be cleaned and flushe...

Page 6: ... then the user must assume all costs incurred returning and or storing the product All products and parts will be tested using SMK testing criteria Units found to be damaged altered or otherwise mistreated will not be covered under this warranty Units found not to be defective are subject to charges to be paid by the returnee Page 5 Operating the Sprayer Keeping all safety and operating measures i...

Page 7: ... special or consequential damages of any kind by the reason of use or sale of any defective product or part This limited warranty covers units distributed in the United States of America only This limited warranty is in lieu of all other warranties expressed or implied and no other person is authorized to give any other warranty or assume obligation or liability on behalf of SMK Industries Inc Pro...

Page 8: ...accounted for and no damage has occurred during shipment Page 7 Assembly To prepare the unit for operation assemble the sprayer as follows 1 Spray Tip a The Wand comes preassembled with an Adjustable Cone Tip b An optional 0 1 GPM Tapered Fan tip and Check Valve with Screen is provided in a Shipping Bag 2 Assemble Spray Hose a Attach Spray Hose to the Spray Gun and Sprayer Unit Both ends are the s...