background image

SMOKE-FACTORY – 

DATA II 

Operating Instructions

 

5  Operating the  DATA II 

 

The 

DATA II 

is a powerful fog generator, producing every desired effect from a tiny puff of smoke to 

the thickest fog. Digital technology makes fine adjustments of the pump possible. In steps of 1% the 
output can be adjusted from 1-99%.

  

5.1 

Control panel  DATA II 

 

 

 

 

• 

TIMER-LED, red 

• 

READY-LED, green 

• 

DMX IN-LED, yellow 

 
 
 

• 

MODE 

 
 

• 

UP/DOWN 

• 

ENTER

 

 
 
 
 

5.2 

Switch of the device 

 

Press the Mode butten         

til  „OFF“ 

appears on the display.

 

 

  

 

After 15 seconds the machine will switch off automatically. On the right bottom edge of the display a 
red decimal point appear.

 

 

 

 

You can also switch off the machine within these 15 seconds by pressing the Enter-button. 

 

When you switch off the DMX signal, the machine will be switched off automatically after 15 
seconds.

 

 
 
 
 
Please note that the Mode button is not    

designed to scroll between the different menus.   

 
If you press the mode button longer than 2 sec. the display will change into the timer menue.

 

 

SMOKE FACTORY   
 

issue 1.0    Page: 7 of. 15 

 

FOG GENERATORS  NEBELMASCHINEN

  

Summary of Contents for Data ll

Page 1: ...SMOKE FACTORY Operating Instructions DATA II ...

Page 2: ...ERATING THE DATA II 7 5 1 CONTROL PANEL DATA II 7 5 2 SWITCH OF THE DEVICE 7 5 3 CONTROL CHOICES 8 5 3 1 External control 8 5 3 2 Operating via DMX 512 8 5 3 3 Stand alone 9 5 3 4 Operating cable remote and 0 10V DC 10 5 3 5 Control via Radio remote 10 5 3 6 Wiring of DMX und Analog 0 10V DC 10 5 4 OPERATING WITH INTERNAL TIMER 11 5 5 AUTOSTART 12 6 CLEANING CARE AND MAINTENANCE 12 7 TROUBLE SHOOT...

Page 3: ... Glycol is alcohol and burns with a slightly bluish almost invisible flame Never point the fog at strong sources of ignition like fire or pyrotechnic effects The visibility has to be more than 2 m in rooms where people walk around Never open the machine and leave the machine unattended when connected to a power supply Do not swallow the fog fluid Keep it away from children In case of eye contact r...

Page 4: ...ption of parts Control panel DMX IN DMX OUT XLR socket 0 10 v DC and radio remote Fuse for external fan Socket for external fan Main cable Fluid bottle holder Fluid tube with quick coupler SMOKE FACTORY issue 1 0 Page 4 of 15 FOG GENERATORS NEBELMASCHINEN ...

Page 5: ...SMOKE FACTORY DATA II Operating Instructions 3 1 Front view Handle Tube connector and nozzles SMOKE FACTORY issue 1 0 Page 5 of 15 FOG GENERATORS NEBELMASCHINEN ...

Page 6: ...ids FAST FOG Thick fog very quickly dispersing SUPER FOG Medium thick standard fog long lasting HEAVY FOG Thick fog very long lasting DESIGNER FOG Transparent fog very long lasting high light reflexion grade Use only original SMOKE FACTORY fog fluids Other Fluids can cause considerable damage to the unit and void the warranty You can get more general information about fog fluids from your dealer o...

Page 7: ...ice Press the Mode butten til OFF appears on the display After 15 seconds the machine will switch off automatically On the right bottom edge of the display a red decimal point appear You can also switch off the machine within these 15 seconds by pressing the Enter button When you switch off the DMX signal the machine will be switched off automatically after 15 seconds Please note that the Mode but...

Page 8: ...w the pump and the fan can be adjusted via the desk Please note If a fan is connected to the machine the DATA II uses two channels at your desk Channel 1 Pump Channel 2 Fan Adjusting the DMX start address Press the Mode button at the control panel until three figures will appear on the LED display Adjust the requested start address by pressing the Up Down buttons Save the start address by pressing...

Page 9: ...h the Up Down buttons Press the Enter button once to start the fogging process The machine now produces fog until the Enter button is pressed again The output can be changed during the fogging process Press Mode again to adjust the fan output Adjust the fan output with the Up Down buttons 0 99 Press the Enter button once to start the fan The output can be changed during the process The fan will wo...

Page 10: ... output press the Mode button until a F and two figures appear on the display Adjust the fan output with the Up Down buttons 5 3 5 Control via Radio remote A radio remote is available as an option It will be delivered with a 3pin XLR plug Connect the receiver of the radio remote to the machine by using the 3pin XLR socket on the back of the machine Adjust the requested pump output at the machine s...

Page 11: ... As long as the timer is in operation the red Timer LED blinks With the Up Down buttons you can adjust the output Pxx 1 99 Pressing the Mode button once will bring you to the setting for the wait time With the Up Down buttons you can adjust the wait time 0 1 99 minutes Pressing the Mode button once will bring you to the setting for the fog time With the Up Down buttons you can adjust the fog time ...

Page 12: ...Cleaning care and maintenance Ensure the air vents are not clogged by dust If necessary remove the dust Take care that the machine can not get overheated Do not run the DATA II without any fluid as the pump will run dry Wipe up spiled Fluid immediately Moisture also fluid can destroy the electric of the machine Check the state of the air valve filter from time to time and clean or replace it when ...

Page 13: ...move external heat source for instance projector shining right onto the housing and or make shure sufficient fresh air supply After 15 to 30 minutes the unit should switch back to on again Loud droning sound during fogging The pump is running dry Avoid this absolutely Refill fluid bottle Double check connection fluid tube and fluid bottle E 4 appears on the LED display The machine is getting too h...

Page 14: ...utput approx 40 sec at 50 output continuous output eternal Fan max 800 Watt fan with one phase Air quantity adjustable fron 0 99 Control DMX 512 0 10 V analog internal Timer Stand alone mode Radio remote Option Temperature control Microprocessor controlled Overheating protection Heater block Thermostat Pump Thermal switch Fuse external fan 5 Ampere slow blow Dimension L x B x H 55 x 32 x 47 cm Wei...

Page 15: ...or if spare parts are used which are nor approved by us The right of guarantee service is also lost if fluids other than Glycolwater based fluids have been used or if units are sent to us with full fluid bottles Also non compliance with the instructions in this manual or mistakes by incorrect handling treating of the machine will lead to a loss of guarantee and also any faults and damages caused b...

Reviews: