5.4
Operating with internal Timer
With the internal timer the „fog time” and ”wait time” as well as the output can be adjusted.
The output of the external fan has to be adjusted in the Standard-Menue and
can‘t be changed in the Timer-Menue.
To start the Timer-Mode, press the Mode-button for more than 2 seconds.
The red Timer-LED] shines as soon as the machine has switched to the Timer-Mode. As long as the timer is in
operation, the red Timer-LED blinks.
With the Up/Down-buttons you can adjust the output (Pxx),
(
1-99%)
Pressing the Mode button once, will bring you to the setting for the wait-time.
With the Up/Down-buttons you can adjust the wait-time
(
0.1-99 minutes
).
Pressing the Mode button once, will bring you to the setting for the fog-time.
With the Up/Down-buttons
you can adjust the fog time in seconds
(
1-99 sec
.)
Please note that with beginning of the fogging process the external fan also will start .
Pressing the Mode button once, will bring you to „Escape“
SMOKE FACTORY
issue 1.0 Page: 11 of. 15