background image

 
 
 

 
 
 

® 

BTD 

6

 

USE AS DRIPPER 

The positive pole screw, which is installed in the Taifun® BTD, has a channel through which the liquid is led to the coil. 
Alternatively, this screw can also be replaced by a closed version (included in delivery). With this screw the Taifun® 
BTD can also be used as a regular dripper. 

First, the positive pole screw is unscrewed. Now the positive pole in the inside gets loose. If necessary, hold it with 
one finger. Then the positive pole screw is replaced and screwed back in again. It fixes the positive pole inside. Make 
sure that the positive pole sits correctly in the insulator and is not bent or twisted. 

When changing the positive pole screw, there should be no coil in the device. 

 

 

 

 

 

 

Unscrew the positive pole screw

 

 

Replace positive pole screw

 

 

Screw back again the positive  

pole screw

 

 

8. CLEANING  

Do not use cleaning agents as they could harm the o-rings. 
Before assembling, check the completeness and positioning of the o-rings to prevent leakage of liquid. 
• Disassemble the device into its components. 
• 

Do not

 remove the PEI insert in the top cap.. 

• Clean the components (not the cotton) with warm water or in an ultrasonic bath. 
• Completely dry the components before reassembling the device. 
 

9. MAINTENANCE 

• Wait until the device has completely cooled down before disassembling, to prevent burns. 
• Make sure that there is no power supply by unscrewing the device from the mod or by switching off the mod. 

 

 

Summary of Contents for Taifun BTD

Page 1: ...ath and coughing fits in the case of a previously damaged lung If complaints occur please seek medical attention immediately Do not use our product if you have a known problem allergies intolerances e...

Page 2: ...Make sure that the mod that you use with the device is capable of performance Use of unregulated mods or mods without protection is not recommended 3 MANUFACTURER RECOMMENDATIONS The resistance of th...

Page 3: ...th the allen screws Make sure that the coil points downwards Cut the coil ends Make sure that the coil glow evenly from the inside to the outside and do not form any heat spots WARNING Use an ohm mete...

Page 4: ...to be able to absorb the liquid Then pre moisten the cotton with liquid PREPARATION AND ADJUSTMENT Now the top cap will be put on again A turn on the top cap regulates the airflow By pressing the liq...

Page 5: ...r vape with completely closed airflow control Make sure there is sufficient air supply at higher wattage levels USE OF AN ALTERNATIVE DRIP TIP The drip tip of the Taifun BTD can be exchanged for anoth...

Page 6: ...ot bent or twisted When changing the positive pole screw there should be no coil in the device Unscrew the positive pole screw Replace positive pole screw Screw back again the positive pole screw 8 CL...

Page 7: ...ier The Insulator 2 is placed on the positive pole 1 The positive pole 1 is inserted into the base 3 together with the insulator 2 The positive pole screw 7 is pushed through the insulator 8 into the...

Page 8: ...cap is a PEI insert Under no circumstances this should be remo ved as otherwise there is a risk of a short circuit and the airflow control will be rui ned Even at an intensive cleaning of the device...

Reviews: