5.  Winter Mode

 Y/N (default N). Winter mode shuts the system down when the 

outside air temperature gets below eg 2°C.  If Winter Mode is on, another menu 

item will appear to allow adjustment of actual shut down temp: Range -2°C to 

+5°C.

6.  Filter Timer

 

Y/N (default N) – Controller counts hours run by the fan and when 

filter is due for a change the display flashes with ‘Filter’.  If filter timer set Y, 

another menu appears allowing filter period adjustment (240 day) (range 150 

- 240 days).  A further menu item will appear at user level once filtered timer 

timed out, allowing timer to be reset once filters are cleaned or replaced.

7.  I/Side Ref Temp

 (default 18°C) Range 16-24°C.  This is the reference 

temperature for the inside of the house,  used for:

•  Heating – when house temp (IS) is lower than 18°C (default) and outside 

temp (OS) is lower than 12°C (default) the heater will operate (if fitted).

•  Summer – when house temp (IS) is higher than 18°C (default) and outside 

temp (OS) is higher than 27°C (default) the unit will shut-down.

8.  O/Side Ref Temp 

(default 12°C) Range 8-16°C. This is the reference 

temperature for the outside air, below which heater operates (if fitted).

9.  O/Side Degree Offset

 (default 0°C) this allows unit to be calibrated in the 

unlikely event that outside air temperature reads too high or low (adjustment 

range -10°C to + 10°C).

10. I/Side Degree Offset

 (default 0°C) - As above.

11.  Heat P/band 

(default 5°C) Range 1-7°C. Heat Proportional Band - When heater 

is fitted and conditions call for its operation, heater will start heating at 20% 

when OS (outside) drops to reference temp (default 12°C), and will operate at 

100% when temperature has dropped by a further (default) 5°C (ie when OS is 

7°C).

12. Summer Temp S/down

 (default 27°C) Range 25°-35°C. When OS (outside 

temp) is greater than 27°C and IS (inside temp) is greater than 18°C, the 

system shuts down.

13. User Sys 

On/Off (default Off) - when On, user menu has option to turn system 

On/Off.

14. Factory Reset 

Y/N (default N). Yes defaults all menu items to factory default 

setting, these default settings are shown in brackets above. 

Heater option not available for HEXdigi-NH

Heater option not available for HEXdigi-NH

Heater option not available for HEXdigi-NH

Heater option not available for HEXdigi-NH

Digital Controller setup instructions continued on next page

• 

Optional Attic Damper Kit.

  A diverting branch can be attached to divert 

the intake from the cooler outside air to the attic. Press mode       and       up 

arrow together until ‘

Entering menus

 displays, hold until ‘

Damper is on

 or 

Damp

er is off

’ displays.  

Change damper? ON

’ or ‘

Change damper? OFF

’ then 

displays.  Use the up arrow to change between the two settings.

Summary of Contents for HEX390 digi

Page 1: ...Air to outside HEX Heat is transferred to or from the incoming fresh air HEX390 Heat Exchanger with Digital or Manual Controller Cleaner Warmer Drier Healthier Homes Operating Instructions p2 4 Installation Instructions p5 8 Setup Instructions digi p9 12 Wiring Diagrams p13 14 Congratulations on purchasing a HEX Energy Recovery Ventilation Unit Manual controller Digital controller ...

Page 2: ...IONS 0 5mm UNLESS STATED This is Smooth Air Products copyright and contains proprietary owned intellectual property rights and confidential data All rights are strictly reserved The information must not be used except for the agreed purpose Unauthorised use reproduction or issue to any third party is not permitted without the prior written authority of Smooth Air Products This document is to be re...

Page 3: ...meowner can use to regulate the fresh air amount to suit the load Typically High where a number of people are living in the house and or outside temperatures are moderate Medium less people in the house and or colder outside temperatures Low mainly to keep air fresh in the home during extremely cold conditions Internal On off thermostat optional For the manual controller the optional thermostat ca...

Page 4: ...ions on purchasing a HEX Heat Recovery Ventilator with Digital Controller This controller allows the user to adjust fan speed from high to low fan limits are set in the commissioning menu to suit the size of house and system layout The controller will automatically shut down in summer if outside air temperature OS exceeds 27 C and home is warm There are a number of other features available at time...

Page 5: ...4 p15 digital controller Supplied HEX unit HEX attic box Triple rocker switch inside attic box Drain adaptor inside HEX filter access door Required Primary extended surface filters External inlet and outlet grilles Internal supply and return grilles Duct Tape 3 and 4 core wire Drain condensate hose 2 Mount Unit securely in ceiling space eg use bungees to hang or anti vibration pad where it can be ...

Page 6: ...eturn air Mount return air grilles as suits the homeowner eg one in the bathroom and one at the other end of the hall from supply grille 6 Filters inside unit are secondary filters Mount hinged filter grilles eg PYHF400 or extended surface filters eg FBP200 in ducting prior to unit for return air from house as well as fresh intake air 3 Drain installation Drain adaptor supplied inside HEX filter c...

Page 7: ...e drilled hole and fixed with the cable tie It is then plugged into the attic box as pictured above Cat5 cable to digital wall controller For digital controller mount with pack glands downwards Terminate separately the grey brown wires from the HEX unit 8 Mount Attic box Attic box can be mounted on the unit or anywhere in the attic The hall controller digital or manual 3 speed will be shipped insi...

Page 8: ...tal Controller If there is an internal On Off thermostat this should be disabled for digital controller as the digital controller should control all airflows 10b Internal On Off thermostat optional Manual Controller The optional thermostat can be set so the unit turns off if incoming air exceeds the set point eg if thermostat is set to 30 the unit will turn off if the incoming fresh air is above 3...

Page 9: ...the menu Options are on following pages Digital Controller Setup Instructions The Heat Recovery Digital Controller has a number of features available to customize the system to suit house size layout and user preferences The Setup menu is accessed by pressing the buttons together for about 5 seconds until the display reads Setup Menu The controller comes preset with default factory settings these ...

Page 10: ...using up down arrows For a large house set to a max of 100 3 Min Fan Speed default 10 Range is 10 to 100 adjustable in 10 increments using up down arrows For a large house set to a min of 50 4 Fan Speed Heat default 50 Range is 10 to 100 adjustable in 10 increments using up down arrows Fan Speed Heat sets a minimum speed for the fan to ensure enough airflow for the heater to operate There are many...

Page 11: ...O Side Degree Offset default 0 C this allows unit to be calibrated in the unlikely event that outside air temperature reads too high or low adjustment range 10 C to 10 C 10 I Side Degree Offset default 0 C As above 11 Heat P band default 5 C Range 1 7 C Heat Proportional Band When heater is fitted and conditions call for its operation heater will start heating at 20 when OS outside drops to refere...

Page 12: ...ter Mode Y N If Y shut down temp C 6 Filter Timer Y N If filter timer Y days 7 I Side Ref Temp C 8 O Side Ref Temp C 9 O Side Degree Offset C 10 I Side Degree Offset C 11 Heat P band C 12 Summer Temp S down C 13 User Sys On Off 14 Factory Reset Y N Optional attic damper kit installed Y N Installer Details Heater option not available for HEXdigi NH Heater option not available for HEXdigi NH Heater ...

Page 13: ...man HEX390digi Operating Instructions Installation Instructions Wiring diagrams Sept 2015 13 Wiring for manual 3speed switch The attic box also comes with a two core wire for use with the optional thermostat ...

Page 14: ...or HT15 only Heater for HT07 HT15 Optional Attic damper kit 1 2 3 P N P1 N P3 N NC C 240VAC MOTOR HEAT Vent Circuit Board Patch lead socket Isolator Switch NO Heat Sensor Plug Grey HT15D Only Green Blue Brown Grey Mode Fan Diverting Branch Motor Heater 1 2 3 N P P N If damper operates in reverse change CW CCW switch on motor body to correct Diverting branch motor Hall controller For heated units o...

Page 15: ..._______________________ Date of installation ________________________________________________________ Installed by _____________________________________________________________ HEXdigi Attic box wiring diagram Heater option not available for HEXdigi NH HEX Warranty 24 months manufacturing warranty from date of first retail purchase This HEX product when delivered to you in new condition from a HEX...

Page 16: ...e Exhaust Air to outside HEX Heat is transferred to or from the incoming fresh air Display Key OS Outside Air Temperature IS Inside Air Temperature Winter Winter mode is on H Heater is fitted Fan Speed Status Outside Air Temp OS Operating Mode Inside Air Temp IS Fan Speed Increase Y Ntoggle Time Fan Speed Decrease Mode to scroll Heater option not available for HEXdigi NH ...

Reviews: