32
SMOOTH CE3.0 ELLIPTICAL TRAINER
TROUBLESHOOTING
Item Breakdown
Troubleshooting
1
Computer will not
power up
1. Plug the power adaptor in to the wall outlet
2. Plug the power adaptor jack in to the unit.
3. Test the wall outlet for power.
4. Test the power adaptor for the correct voltage output.
5. Check the power adaptor and adaptor wire for damage.
6. Check for damaged computer cables then reconnect the lower, upper and console
cables found on page 5 and 10 of the assembly section.
2
No resistance level
change
1.When the resistance level is changed does the motor run?
Yes
2.Check for damaged computer cables then reconnect the lower, upper and console cables
found on page 5 and 10 of the assembly section.
3. Retest resistance
3
NO Hand pulse
figure display
1. Reposition hands on the pulse grip Do not hold one pulse grip with 2 hands.
2. Reconnect the pulse grip wire inside the pulse grip handle
3. Reactivate the computer
4
E-1
1. E-1 Indicates the computer was not able to calculate the body fat. Reposition hands on
the pulse grip. Do not hold one pulse grip with 2 hands.
5
E-4
1. E-4 indicates the user’s age, height, weight values have exceed of the maximum setting
range when entering the user information. Reenter values that do not exceed the
maximum values.
6
E-2
1. Check for damaged computer cables then reconnect the lower, upper and console
cables found on page 5 and 10 of the assembly section.
2. Check the Motor and resistance cable for proper positioning.
7
No speed reading
1.Check the console together with the stage’s 9or12PIN connect cable, to see if the
console are bad contact or get loose with the stage’s 9or12PIN connect cable.
2. Check the Motor distance have exceed of the setting range or not.
8
No display of
SPEED figure
1. Check for damaged computer cables then reconnect the lower, upper and console
cables found on page 5 and 10 of the assembly section.
2. Check the Speed SENSOR cable for damage and reconnect to the lower board.
Check the speed sensor and speed sensor magnet for proper positioning.
9
Recovery function
does not readout
1 Verify the console is in the STOP mode and is not in a program.
2. Verify the pulse readout is functioning.
10
Noisy during
Movement
1.Check slider tubes for damage
2.Clean slider tubes with liquid silicone
3.Check pedal arm wheels for damage.
4.Clean pedal arm wheels with mild detergent and lubricate with liquid silicone
11
Noisy handlebars
1.Disassemble lower handle bars and check for damage.
2.Lubricate with white lithium grease and reassemble.