16
is below the
minimum allowed
temperature; if configured:
the signal relay is activated,
an audible signal beeps
temperatures
(function is activated
according to
customer's request)
„uHi“
Mains voltage is
higher than the
maximum allowed (if
programmed
according to
customer's request)
"UHi"
flashes. If configured:
the signal relay is activated,
an audible signal beeps.
High voltage alarm
(function activated
according to
customer's request).
„uLi“
Mains voltage is
lower than the
minimum allowed (if
programmed
according to the
customer's request)
"ULi"
flashes. If configured:
the signal relay is activated,
an audible signal beeps.
Low voltage alarm
(function activated
according to
customer's request).
„dor“
Open door
„do
r“
flashes
More than 3 min open
door
„E01“
Temperature sensor
error
Flashes
„E01“.
If configured;
the signal relay is activated,
an audible signal beeps.
Temperature sensor
failure (short circuit,
or broken)
„E02“
Evaporator sensor
error
Flashes
„E02“.
If configured;
the signal relay is activated,
an audible signal beeps
Evaporator sensor
failure (short circuit,
or broken).
„E03“
Condenser sensor
error (if installed
according to
customer's request)
Flashes „
E03“.
If configured;
the signal relay is activated,
an audible signal beeps.
Condenser sensor
failure (short circuit,
or broken).
CLEANING AND MAINTENANCE
THE REFRIGERATOR DEFROSTS AUTOMATICALLY.
Defrosting can also be switched
on manually (long-pressing the "down" key in Fig. 2 shows
"dEF"
). When defrosting is
complete, the appliance returns to the previously set operating mode.
CLEAN THE REFRIGERATOR REGULARLY.
Component
Type of operation Periodicity
Who performs
Internal cabinet
Cleaning
If necessary
Operator of
appliance
External surfaces
Cleaning
If necessary
Operator of
appliance
Condenser
Cleaning
At least once every
60 days
Operator of
appliance
Remember to unplug the appliance before and during cleaning - unplug
the appliance from the mains.