PROCEDURE FOR PREPARING FRL FOR USE WITH LIFT:
1.
Disconnect shop air from FRL inlet. Adding Oil to the lubricator cannot take place under a
pressurized condition.
2.
Using a slotted screwdriver or an Allen key, remove the filler cap from the top of the FRL.
3.
Fill FRL using Snap-On AirOil #IM6 or equivalent. Oil to be filled to the MAX line marked on
reservoir.
4.
Replace filler cap to top of FRL.
5.
With the output end of the FRL disconnected (remove the quick disconnect fitting), reconnect
the air line to the FRL unit. Air will flow freely through the FRL.
6.
Perform Drip Check / Adjustment: Drips to be set to 2-3 per minute.
Disconnect shop air.