Note: When date and time is set for first time, In-Service date is also set and is used for calculating initial
calibration interval (see "Setting Calibration Interval" in Advanced Configuration section).
Note:
If wrench is powered up in torque only measurement mode, angle is not zeroed until mode is changed
to angle measurement mode, at which time torque and angle zeroing begins automatically after 2
seconds. Wrench should be placed on a stable surface with no torque applied.
Note: Pressing ENTER button while angle is zeroing will abort zeroing function to allow user to select another
measurement mode.
Torque Mode
1.
Set Target.
Use UP/DOWN buttons to change TORQUE target value.
2.
Select Units of Measure.
Repeatedly press UNITS button while on target TORQUE screen until desired units are displayed.
3.
Apply TORQUE.
Grasp center of handle and slowly apply torque to fastener until progress lights display green and a
½ second audible alert and handle vibration alerts you to stop.
4.
Release TORQUE.
Note peak TORQUE reading flashing on LCD display for 5 seconds. Pressing BACKLIGHT button while
peak torque is flashing will continue to display value until button is released. Momentarily pressing
UP/DOWN, ENTER or UNITS button will immediately return to target TORQUE screen. Reapplying
TORQUE will immediately start another TORQUE measurement cycle.
5.
Recall Peak TORQUE Reading
To recall last peak TORQUE measurement, press and hold BACKLIGHT button for approximately 3
seconds. Peak TORQUE will flash for 5 seconds.
Angle Mode
Note: When angle measurement mode is selected for first time following a power on, "ANGLE ZERO REQUIRED"
message is displayed. After two seconds angle zero process begins and wrench must be placed on a stable
surface. If ENTER button is pressed before two seconds to change to torque only mode, angle zero process
is skipped.
1.
Set target.
Use UP/DOWN buttons to change target ANGLE value.
2.
Apply Torque and Rotate Wrench.
Grasp center of handle and slowly apply torque to fastener and rotate wrench at a moderate
consistent speed until progress lights display green and a ½ second audible alert and handle vibration
alerts you to stop.
3.
Release torque.
Note alternating peak TORQUE and ANGLE readings flashing on LCD display for 5 seconds. Pressing
BACKLIGHT button while peak values are flashing will continue to display values until button is
released. Momentarily pressing UP/DOWN, ENTER or UNITS button will immediately return to target
ANGLE screen. Reapplying torque (ratcheting) before target screen is displayed will continue ANGLE
accumulation as wrench is rotated.
4.
Recall Peak ANGLE Reading
To recall last peak ANGLE measurement, press and hold BACKLIGHT button for approximately 3
seconds. Peak TORQUE and ANGLE will be displayed alternately for 5 seconds.
Mode Cycle Count
ControlTech™ mode cycle count feature is used to indicate number of
times wrench has reached target torque in torque measurement mode
or target angle in angle measurement mode.
01
M
180°
MEMORY ICON
MODE CYCLE COUNT