2-12
IInnssttaallllaattiioonn
aanndd
O
Oppeerraattiioonn
Evacuating A/C System
Use this procedure to remove air and moisture from vehicle A/C
system.
3
3
3
3
If gauges indicate pressure, recover refrigerant from
service hoses before proceeding. Refer to
Evacuating
Service Hoses
in this Chapter.
1. Open the following:
—
Red service hose hand valve or coupler,
—
Blue service hose hand valve or coupler,
—
High side manifold hand valve, and
—
Low side manifold hand valve.
2. Turn Compressor switch ON.
3. Turn vacuum/recycle valve to VACUUM.
Low side manifold gauge shows vacuum increasing.
3
3
3
3
Follow manufacturer recommendations for evacuation
time, usually at least 30 minutes.
4. Close manifold hand valves when desired vacuum and
duration have been reached.
5. Turn Vacuum/Recycle valve OFF.
6. Turn compressor switch OFF.
COMPRESSOR ON indicator goes out and compressor
stops running.
7. Monitor low side pressure for 5 minutes.
Any rise in vacuum indicates a leak in vehicle system.
3
3
3
3
If source of leak cannot be determined, partially charge
system and perform leak test using electronic leak
detector.
8. When leak is identified, repeat Recover/Recycle
proceedure, repair leak and attempt Evacuation
proceedure again.
Evacuation is complete.
Summary of Contents for Dual 3412
Page 2: ...ii T Ta ab bl le e o of f C Co on nt te en nt ts s ...
Page 8: ...viii U Us si in ng g t th hi is s M Ma an nu ua al l ...
Page 14: ...VI S Sa af fe et ty y I In nf fo or rm ma at ti io on n ...
Page 26: ...1 12 I In nt tr ro od du uc ct ti io on n ...