3-8
M
Maaiinntteennaannccee
Wear safety goggles and protective gloves, user
and bystander.
Read, understand and follow
S
Saaffeettyy
IInnffoorrm
maattiioonn
in
the front of this manual.
6. Disconnect all tubing and electrical connections from
pump. Taking note of their locations.
3
3
3
3
Discard the O-rings from hose tube ends.
7. Remove the four bolts holding the pump to the base.
8. Remove the pump through the top opening of the unit.
9. Tilt pump over an oil drain pan so the process port is
straight down. Oil drains from this port. Approximately 9
oz. of oil should be recovered.
10. If approximately 9 oz. of oil is not recovered, repeat step
9.
11. Use plastic bottle supplied with oil change kit to pour 9.3
oz (275 cc) of 3GS compressor oil, part number 681-
0179-2, into input port of pump (top port).
12. Reinstall pump and four bolts at base.
13. Install new O-rings on ends of the tubing and hose
assemblies.
14. Place a small amount of compressor oil on O-rings and
reinstall tubing assemblies. Torque to 65 in. lbs..
15. Reinstall electrical connections.
16. Replace top cover.
17. Replace front cover.
Storing
D
Duuaall
33441122
Follow this procedure when storing
D
Duuaall
33441122
for prolonged
periods, (3 months or more).
1. Change pump oil using
Maintaining the Pump
procedure in this chapter.
2. Close all hand valves on both recovery tanks.
3. Close service hose, coupling and manifold valves.
Summary of Contents for Dual 3412