36
Scanner
Operations
Figure 5-14
Sample save dialog box
The
Shortcut
key can be programmed to perform the Save Screen or Save Movie function. See
“Configure Shortcut Key“ on page 54
for details.
Setting Trigger Levels
The PID Trigger button on the toolbar allows you to configure the scan tool to automatically
capture data when a parameter value crosses a threshold value. When triggering is armed, a
“trigger event” pauses data collection and records a data movie, similar to an OBD-II/EOBD
freeze-frame event.
Selecting the
PID Trigger
button opens a menu that includes:
•
Set Trigger
—establishes upper and lower signal values to initiate an event capture for the
highlighted parameter.
•
Arm Trigger
—activates the scan tool to capture an event when the signal crosses a
threshold.
•
Clear All Triggers
—deletes all previously set trigger levels.
If triggers are set the menu options are:
•
Clear Trigger
—deletes set trigger levels for the highlighted parameter.
•
Disarm Trigger
—de-activates event capture capability.
•
Clear All Triggers
—deletes all previously set trigger levels.
z
To set trigger levels:
1. Highlight the parameter to be used to trigger the recording.
2. Tap the
PID Trigger
button.
3. Select
Set Trigger
from the dropdown menu.
A graph of the highlighted parameter with a trigger toolbar above it fills the main body of the
screen. The trigger level line displays as a solid line running horizontally across the data graph
(
). An upper and lower trigger level must be set, the upper level is set first.