background image

GENERATOR CAPACITY AND APPLIANCE WATTAGE

Ensure generator can supply adequate rated (running) and surge (starting) wattage
for devices it will power at same time. Follow the steps below:

1. Select all devices that will be powered at the same time.

2. Total rated running watts of devices. This is amount of power the generator

must produce to keep devices running. See table below.

3. Estimate amount of surge (starting) wattage needed. Surge wattage is a short

burst of power needed to start electric motor-driven tools and appliances such
as an electric compressors, pumps, drills or refrigerators. Because not all
motors start at same time, total surge wattage can be estimated by adding only
the item(s) with highest additional surge watts to the total rated watts as
described below.

EXAMPLES OF RATED AND SURGE WATTAGE

TOOL OR APPLIANCE

Total Rated (Running) Watts

= 2500

Highest Additional Surge Watts

= 2400

Total Generator Output Required

= 4900

Never add more loads to generator than it has capacity for. Take additional
care to consider surge loads in generator capacity.

Exceeding generator load

limit can result in damage to unit and to appliances or tools connected to it.

Exceeding generators wattage/amperage capacity can damage generator
and/or any electrical devices connected to it.

Improper treatment of generator can damage internal components and 
shorten the life of unit.

Exhaust heat/gases can ignite combustible materials, structures or
damage to fuel tank resulting in fire.

Keep at least 5 ft. (1.5 m) 

clearance on all sides of generator including overhead.

DO NOT

exceed wattage/amperage capacity. See “Generator Capacity” section of

this manual.

• If connected devices overheat, turn them 

OFF

and disconnect them from generator.

• Use a ground fault circuit interrupter (GFCI) anywhere dampened or highly 

conductive areas, such as metal decking or steel work.

DO NOT

touch bare wires or outlets. Severe burns or even death can result.

DO NOT

use generator with electrical cords which are worn, frayed, bare or 

otherwise damaged.

DO NOT 

handle generator or electrical cables while standing in water, while

barefoot or whenever hands and feet are wet.

DO NOT

connect 3-phase loads to generator.

DO NOT

connect 50 Hz loads to generator.

• Always connect electrical loads to generator while the load is turned 

OFF

. After

connecting loads to generator, turn the load 

ON

.

• Always turn electrical loads 

OFF

and disconnect them from generator before

stopping generator engine.

24

23

Tool or Appliance

Rated (Running) Watts

Additional Surge

(Starting) Watts

Window Air Conditioner

1200

1800

Refrigerator

800

1600

Television

500

Summary of Contents for SR3000

Page 1: ...CUSTOMER SERVICE DEPARTMENT AT 1 888 278 8092 BEFORE YOU CALL HAVE THE FOLLOWING INFORMATION AVAILABLE MODEL No DATE PURCHASED AND STORE LOCATION AN ALLTRADE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE SNAP ON IS A TRADEMARK LICENSED BY SNAP ON CORP U S A WHICH DOES NOT MANUFACTURE OR DISTRIBUTE THIS PRODUCT CONSUMER INQUIRES SHOULD BE DIRECTED TO COPYRIGHT 2009 ALLTRADE TOOLS LLC 1431 ...

Page 2: ...ctions provided in this manual are not intended to cover all possible condi tions and practices that may occur when operating maintaining and cleaning power tools Always use common sense and pay particular attention to all the DANGER WARNING CAUTION and NOTE statements in this manual This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messag...

Page 3: ... WARNING These same precautions are placed as labels on the tool itself NEVER use this generator for applications that are NOT specified in this manual DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a pote...

Page 4: ...before turning ON the tool Do not overreach Proper footing and balance is a must at all times while using tools Unstable support may lead to personal injury Do not stand on the tool Serious injury could result if the tool tips over or you accidentally contact tool When using accessories consult the owner s manual provided by the manufactur er The use of improper accessories may cause risk of injur...

Page 5: ...eping the tool clean dry and free of grime will add to its life and performance Do not use the tool for applications other than specified SAFETY RULES FOR GASOLINE ENGINES Carbon monoxide is a product of incomplete combustion such as exhaust from the engine Carbon monoxide is colorless odorless and tasteless and can kill in a matter of minutes Gas particulate filters and respirators will not prote...

Page 6: ...k or other parts of the engine where damage can result from sparking Replace a defective spark plug only with authorized parts Use approved spark plug tester DO NOT overfill fuel tank Leave ample space for expansion of fuel DO NOT start engine in area of fuel spillage Fire and explosion can occur Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT smoke while...

Page 7: ...ators can cre ate sparks which may ignite the dust or fumes Never use the generator in damp or wet locations Wear proper apparel Remove your jewelry before using generator Do not wear loose clothing necklaces rings bracelets or other jewelry which may get caught in moving parts Nonskid footwear and electrically non conductive gloves are highly suggested while working Wear protective hair covering ...

Page 8: ...ong time after the battery has been charged The slightest spark will ignite hydrogen and cause an explosion Blindness or serious injury could occur Battery electrolyte fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DO NOT allow an open flame spark heat or lit cigarette near the battery for several minutes after charging battery Wear protect...

Page 9: ...he wheels legs and handle using the provided tool kit and following the procedure in the assembly illustration Make sure all hardware are tightened properly 4 After completion of the assembly carefully place the generator on its wheels and legs 5 Lift the handle and move the generator on a flat surface to verify for proper wheel and handle assembly FUNCTIONAL DESCRIPTION GENERATOR FEATURES 1 Handl...

Page 10: ... cap to allow any pressure to escape Install fuel cap and allow any spilled fuel to evaporate before starting engine DO NOT over tighten handles on generator frame Handles must be allowed to move up and down with ease but not too loose as to rattle during operation of the generator PREPARING THE GENERATOR Improper treatment of generator can damage internal components and shorten the life of unit A...

Page 11: ...ROUNDING TERMINAL is provided on the generator front panel The Ground and Neutral pins in all AC outlets in this generator are BONDED per manently connected to the generator frame and its components See CONNECTING TO A BUILDING S ELECTRICAL SYSTEM section for important grounding information CONNECTING TO A BUILDING S ELECTRICAL SYSTEM Generator produces hazardous voltage Failure to isolate generat...

Page 12: ...5 Again allow generator output to stabilize This will be when engine runs smoothly and attached load functions normally 6 Repeat Steps 4 and 5 for each additional load NEVER start or stop generator engine with electrical devices plugged in and or turned on Damage to both electrical devices and generator can occur Ensure generator is sitting on a level surface When starting generator engine pull co...

Page 13: ...perage capacity can damage generator and or any electrical devices connected to it Improper treatment of generator can damage internal components and shorten the life of unit Exhaust heat gases can ignite combustible materials structures or damage to fuel tank resulting in fire Keep at least 5 ft 1 5 m clearance on all sides of generator including overhead DO NOT exceed wattage amperage capacity S...

Page 14: ...1200 1800 Window Fan 300 600 Furnace Fan Blower 1 2 HP 800 1300 DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 in 500 Personal Computer w 17 in Monitor 800 Light Bulb 75 watts 75 Microwave Oven 1000 Watt 1000 Coffee Maker 1500 Electric Range Single Element 1500 Hot Plate 2500 Security System 180 AM FM Clock Radio 300 3 Push engine rocker switch to OFF position 4 Turn fuel valve ...

Page 15: ...r maintenance will improve performance and extend life of generator Call Customer Service at 1 888 278 8092 for service information Generator s warranty does not cover items that have been subjected to operator abuse or negligence Only by maintaining generator in accordance with instructions in this manual will the full value of the warranty be honored HOUR METER This meter displays the values for...

Page 16: ...Use a soft bristle brush to loosen caked on dirt or oil Use a shop vacuum to pick up any loose dirt and debris Do not use water or other liquids to clean generator Cleaning fluids can enter fuel system resulting in poor performance Additionally if fluids enter generator through cooling air slots portions of the fluid can be retained in voids and cracks of the rotor and stator winding insulation Ov...

Page 17: ...or relocate the generator 4 Contact authorized service facility Cannot shut off Engine 1 Faulty generator circuits or parts 1 Contact authorized service facility Problem Probable Cause Solution Engine lacks power 1 Load is too high 2 Dirty air cleaner 1 Check capacity and refer to Wattage Guide 2 Replace air filter Engine hunts or falters 1 Carburetor is running too rich or too lean 1 Contact auth...

Page 18: ...ice Center within the applicable warranty period with a written request by purchaser to repair and or replace the nonconforming item and or part We recom mend that you keep the original product packaging in the event you need to ship the unit We suggest the package be insured against loss or in transit damage When sending your product include your name address phone number e mail address dated pro...

Page 19: ...shall con stitute fulfillment of all obligations to the purchaser Alltrade shall not be responsible or liable for any expense including freight charges or repairs made outside Alltrade s facility or an Alltrade designated service unless expressly agreed to by Alltrade in writing Under no circumstances shall Alltrade bear any responsibility for loss of the unit loss of time or rental inconvenience ...

Page 20: ... D above warranty services or repairs must be provided at Alltrade Authorized Service Center F When the engine is inspected by an Alltrade Authorized Service Center the pur chaser owner shall not be held responsible for diagnostic costs if the repair is deemed warrantable 38 FEDERAL EMISSION CONTROL WARRANTY STATEMENT OWNER S RIGHTS AND RESPONSIBILITIES The United States Environmental Protection A...

Page 21: ...however be aware that Alltrade may deny you warranty coverage if your generator or any part of the generator has failed due to abuse neglect or improper maintenance or unapproved modifications You are responsible for presenting your generator to an authorized Alltrade Service Center as soon as a problem occurs The warranty repairs should be completed in a reasonable amount of time not to exceed 30...

Reviews: