66
5.7-3
5.7-4
5.7-5
5.7-6
* = Preset by the manufacturer
Operation “
MODE
”
Code C0
Figure 5.7-3
setting operating modes preset by the
manufacturer
0* = No action
1
= Set values preset by the manufacturer (state
1 is displayed only briefl y)
The operating mode selected can be obtained from
the permanent memory.
Code C1
Figure 5.7-4
Selecting the defi nition of the imbalance
value in steps from 1 or 5 grams (= from 0.05 to 0.25
oz.).
0* = 5 gram (0.25 oz) defi nition
1
= 1 gram (0.05 oz) defi nition
The operating mode selected can be obtained from
the permanent memory.
Code C2
Figure 5.7-5
Selecting the suppression of minor imbal-
ance values.
0* = Suppression OFF
1
= Suppression ON
The operating mode selected can be obtained from
the permanent memory.
Code C3
Figure 5.7-6
Selecting the unit of measure for indi-
cating the imbalance (grams/oz) activated after the
machine has come on.
0* = Value in grams
1
= Value in oz
The operating mode selected can be obtained from
the permanent memory.
Summary of Contents for Sun SWB 100