70
5.7-12
5.7-10
5.7-11
* = Preset by the manufacturer
Operation “
MODE
”
Code C8
Figure 5.7-10
Selecting the threshold value for sup-
pressing minor imbalances in grams or oz. The unit of
measure depends on the C3 code setting.
Grammes:
Range 5 to 20.0 g
Factory-adjusted to 5 g
Read out limit, e. g. 5 g
Select another limit, e. g. 5.50 g
—
Press
OK.
Ounces:
Range 0.25 to 2.00 oz
Factory-adjusted to 0.25 oz
Read out limit, e. g. 0.25 oz
Select another limit, e. g. 0.50 oz
—
Press
OK.
After the confi rmation
OK
, this operating mode can be
acquired in the permanent memory (
C10
)
.
Code C10
Figure 5.7-11
Saving an operating mode in the per-
manent memory.
0* = Don’t save
1
= Save the data in the permanent memory.
•
The machine sounds a three tone beep to confi rm
that the data has been saved permanently.
If you have to save the operating mode permanently,
fi rst change the state, e.g. activate it, disable it and
then save it in the permanent memory using the C10
code (this does not apply to C4).
Code C13
Figure 5.7-12
Starting a measuring run by lowering
the wheel guard
0
* = Start a run using the START key
1
= Start a run by lowering the wheel guard
The operating mode selected can be obtained from
the permanent memory.
Summary of Contents for Sun SWB 100