112
Trouble shooting
Code C22
Unclamping of power clamping device locked.
Releasing the power clamping device is disabled
Applies where another clamping device is fi tted,
which is held on the main shaft through the tie rod
(e. g. USV, SCA or motor-cycle wheel adaptor “p“).
0*
=
Unclamping enabled
1
=
Unclamping disabled
The mode C22, when changed, is transferred
automatically into the permanent memory and will
not even be changed again by choosing the modes
of operation as proposed by the manufacturer.
Code C23
Allow unclamping of wheel only if imbalance = 0
and OK.
0* = Unclamping always enabled
1 = Unclamping disabled if not 0 / OK
Code C26
Direction of actuation of pedal for clamping/
unclamping
0* = Clamping/unclamping by lifting the pedal
1 = Clamping/unclamping by depressing the pedal
When changed, the mode of operation C26 can be
transferred into the permanent memory.
Code C28
Select one of the 10 stored error codes and clear
the error memory
The last 10 different error codes are written to the error
memory so that they can be called up and reported
by the operator of the wheel balancer, e.g. for remote
diagnosis of malfunctions. The most recent error code
is written to memory location 1 and the previous error
codes are shifted to the higher memory locations.
—
Select one of the 10 malfunction code messages.
—
Press the
OK
key to display the memory location
(left) and number of incidents (right), e.g. error
code on memory location 7 occurred 4 times.
—
Press the
F6
key for the 2nd step.
—
Press the
F3
key to see the values.
F4
= Clear error memory.