4 Master Section
4.5 Recall
The Recall mode is used to store and recall all settings in 12 memory locations.
4.5.1 Store Preset
Storing to memory can be done in either manual or recall mode. Select the desired memory location
with the Memory/Tempo control, the Recall LED will flash. If the internal clock generator is currently
running make sure that the Memory LED is lit. If it is not press the Recall button before selecting the
memory location, otherwise you’ll change the tempo.
Once the memory destination is selected press the Recall button while holding the Manual button
down. The Recall LED will stop flashing and all parameters have been written to memory.
4.5.2 Recall Preset
To load a preset first select the memory location just like you did for saving. Again, watch for the
memory LED to be lit, otherwise press Recall to switch modes. If, after selecting the memory loca-
tion, the Recall LED does not flash this means that your current settings are equal to that preset and
need not to be reloaded. Otherwise pressing Recall will load the preset and the Recall LED will light
up permanently.
After a preset has been loaded from memory all parameter values need to be “picked up” with the
frontpanel controls before changes take effect. If settings have been changed, both Recall and Man-
ual LED will flash alternatingly, indicating the the preset has been modified.
10