IQH1S 1U Enclosure
SECTION 1
IQH1SINS
23/11/06
www.snellwilcox.com
Version 1 Issue 4
1.1
Installation
Important Installation Notice
To fully conform with EMC standards modules must be correctly installed in the mainframes paying
particular attention to the following:
1. A modular card must only be plugged into a rear connection panel specifically designed for that module
2. The rear of the mainframe must have a full complement of rear panels. Any vacant slots must have a blank
rear panel fitted
3. All mainframe covers and rear panels must be fitted and screwed down using all available fixing holes
4. The mainframe front panel must be in the closed position
1U MAINFRAME
POWER CONNECTIONS
This is the IEC320 mains power connector suitable
for a standard IEC type power cable and contains a
2A (T) HBC 250 V fuse. If a fused type plug is fitted
to the cable a fuse of 7A rating should be installed.
Fuse
100-240V~
60/50 Hz
1.8A
T
T2A H 250V
OPENING AND CLOSING THE FRONT PANEL
To Open
Release the front panel by pulling the front panel
forward and downwards using the release handles
on either side of the front panel.
To Close
Replace the front panel by pushing the front panel
rearwards and upwards using the release handles
on either side of the front panel. Ensure that the
panel is fully seated in the case.