IQH1S IU Enclosure
SECTION 4
IQH1SOPS
23/11/06
www.snellwilcox.com
Version 1 Issue 4
4.19
Slots
This function allows each slot to be named and
interrogated.
Overview
Installed Unit Name
This shows what is fitted in the slot.
Installed Unit ID
This shows the type of the module that is fitted in
the slot.
Editable Name
This allows a slot to be given a user name e.g.
“Chan 1 Encode” and so long as the correct card
stays in that slot this name will be used, as defined
by matching Installed Unit ID and Bound Type ID.
However, if the card is replaced with an incorrect
type e.g. a serial interface, the card will appear by
its type generic name e.g. IQCSPI. Although the
values in this edit box remains the same. When this
entry is edited, the current Installed Unit ID gets
copied to the Bound Type ID.
This function also has the advantage that names
and types may be setup before delivery.
The
symbol represents the Preset function and
will return the name to the installed name and the
ID to the installed ID.
Selecting the
symbol will save the new name
and ID.
Bound Type ID
The Bound Type function allows the slot to be
associated with a particular type of module (e.g. a
encoder type 284). If a module matching this type
ID is fitted, the Gateway will use the user given
name. If an incorrect card type is installed in the
slot the RollCall ID will not be correct and the
actual card type will be displayed in the module
browser.
The names and types may be setup before the
installation of the modules. Edit the Bound Type ID
after editing the Editable Name.
Slot
Number
Installed
Unit ID
Installed
Unit Type
Editable
Name
Bound
Type ID