IQH1S IU Enclosure
SECTION 4
IQH1SOPS
23/11/06
www.snellwilcox.com
Version 1 Issue 4
4.29
Statistics
This function can display various errors that may
occur within a system.
In the event of a problem these error messages
may be quoted to assist debugging.
Enable Net Stats
This item must be checked to enable the errors to
be updated.
Selecting this function will reset all statistics to
zero.
Recons
This item indicates any errors occurring during the
communication of connection data in the Rollcall
network.
Condition
Error value
Normal
0 or constant value
Fault
Value increases at an
unacceptable rate.
Errors occur on a regular basis
Possible Faults
•
Faulty T piece or cable
•
Missing termination(s)
•
Incorrect value of termination(s)
•
Clash of a RollCall Address
•
Network cable length exceeded*
•
Number of units per segment exceeded*
Please refer to
RollCall System Integrators Manual.