background image

IQH1S 1U Enclosure

SECTION 0

IQH1SINS

23/11/06

www.snellwilcox

Version 1 Issue 4

0.8

Table of Contents

SECTION

1

Installation

Power Connections ............................................................................................................ 1.1
Opening and Closing the front panel.................................................................................. 1.1
Power On/Off switch........................................................................................................... 1.2
Front panel Connections .................................................................................................... 1.2
Communication Connections ............................................................................................. 1.3
Hex switches and indicators............................................................................................... 1.3
Installing/Removing a Module ............................................................................................ 1.5
Control Panels.................................................................................................................... 1.7
The RollCall Communications System and Computer Control System ............................. 1.7

Specifications

Summary of Contents for IQH1S 1U

Page 1: ... www snellwilcox com Snell Wilcox Ltd Southleigh Park House Eastleigh Road Havant Hants PO9 2PE United Kingdom For General Enquiry s contact Tel 44 0 2392 489000 Fax 44 0 23 9245 1411 For Technical assistance contact Tel 44 0 2392 489058 Fax 44 0 2392 489057 Web http www snellwilcox com support Ftp ftp ftp snellwilcox com support ...

Page 2: ...nung vorhanden ist Es befinden sich keine vom Benutzer zu wartenden Teile im Geräteinneren Dieses Gerät sollte nur von geschultem Personal gewartet werden Um das Risiko eines Elektroschocks zu reduzieren setzen Sie das Gerät weder Regen noch Feuchtigkeit aus Stellen Sie immer sicher dass das Gerät ordnungsgemäß geerdet und verkabelt ist Dieses Equipment muss an eine Netzsteckdose mit Schutzleiter ...

Page 3: ...heten har två huvudsakliga elförsörjningar säkerställ att båda strömkablarna som är inkopplade i enheten arbetar från samma fas S CAUTION RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS NO USER SERVICEABLE PARTS REFER SERVICING TO QUALIFIED PERSONNEL ONLY Säkerhetsvarningar L N E N L E Stickkontakt Hane Stickkontakt Hona Forklaring på sikkerhedssymboler Dette symbol gør brugeren opmærksom på vigtig in...

Page 4: ... com cabo de alimentação com ficha IEC fêmea standard num extremo e uma ficha IEC macho standard no extremo oposto Se for necessário substituir ou alterar alguma destas fichas deverá remove la e elimina la imediatamente de maneira segura O código de cor para os condutores é o seguinte Condutor VERDE AMARELO ligado a E Terra Condutor AZUL ligado a N Neutro Condutor CASTANHO ligado a L Vivo Atenção ...

Page 5: ...following methods of installation must be used Place the unit on a suitably specified and installed rack shelf and secure the product to the rack via the front rack ears or Fit the unit using the rear rack mount kit available from Snell Wilcox by quoting the order code FGACK RACK MNT KIT This product must not be rack mounted using only the front rack ears ...

Page 6: ...rements for and are intended for use in the commercial and light industrial environment including for example theatres E2 EMC Performance Information Please refer to the Technical Profile Specifications section of the product operation manual EMC Performance of Cables and Connectors Snell Wilcox products are designed to meet or exceed the requirements of the appropriate European EMC standards In o...

Page 7: ...t protection claimed includes all forms and matters of copyrightable material and information now allowed by statutory or judicial law or hereinafter granted including without limitation material generated from the software programs which are displayed on the screen such as icons screen display looks etc Reproduction or disassembly of embedded computer programs or algorithms prohibited Copyrighted...

Page 8: ...llation Power Connections 1 1 Opening and Closing the front panel 1 1 Power On Off switch 1 2 Front panel Connections 1 2 Communication Connections 1 3 Hex switches and indicators 1 3 Installing Removing a Module 1 5 Control Panels 1 7 The RollCall Communications System and Computer Control System 1 7 2 Specifications ...

Page 9: ...e being monitored System Please provide a brief description of the system in which your S W equipment is currently being used Basic Tests Preset Unit Please use the Preset Unit function to return the settings back to the factory default RollCall Is your unit currently connected to a RollCall capable PC This software is obtainable for free and provides a very user friendly GUI for virtually all S W...

Page 10: ...roduct Type Video Products i e Modular Kudos Plus and Alchemist Unit Serial Number Fault Spare Part Information please advise us how many units show this fault and the system layout showing all other manufacturers products e mail Preferred Method of Contact Phone Item is required Please mail to Snell Wilcox Ltd Southleigh Park House Eastleigh Road Havant Hants PO9 2PE United Kingdom Service Contac...

Page 11: ...rd Date Version No Issue No Change Comments 030403 1 1 First Issue released 090605 1 2 Reference to Module power label removed from page 1 6 and power to 60 W pages 1 6 2 1 Complete new manual issued 041006 1 3 For new software New issue released 231106 1 4 Page 1 5 LED status data added New issue released ...

Page 12: ...nd screwed down using all available fixing holes 4 The mainframe front panel must be in the closed position 1U MAINFRAME POWER CONNECTIONS This is the IEC320 mains power connector suitable for a standard IEC type power cable and contains a 2A T HBC 250 V fuse If a fused type plug is fitted to the cable a fuse of 7A rating should be installed Fuse 100 240V 60 50 Hz 1 8A T T2A H 250V OPENING AND CLO...

Page 13: ... on the front panel FRONT PANEL CONNECTOR When an active control panel is fitted to the unit this connector carries the communication signals between the mainframe and the front panel COMMUNICATIONS MODE SWITCH This toggle switch allows the type of communication signal used for the rear panel D connector to be selected The switch should be in the UP position to use RollCall 485 and in the DOWN pos...

Page 14: ...ner to an Ethernet system Both extremities of the system must be terminated in 75 Ohms Note that in a RollCall segment all units must have different unit address codes Note The coaxial link is bi directional and therefore must not be passed through signal switching networks Also to allow hum and noise cancellation the screen of the coaxial connection must not be earthed 100 240V 60 50 Hz 1 8A T T2...

Page 15: ... on these switches may be used to set the Unit Address in Hex Left hand switch 1 to f right hand switch 0 to f If an address is already in use the RollCall receive and transmit LED s will flash alternately at a 1 second rate The unit must then be powered down a unique address selected and the unit powered up again Note that the Shoebox active front panel has a separate and different address to the...

Page 16: ...data is being transmitted via the RS422 connection 4 7 8 2 4 7 8 5V 5V Error STX SRX NTX NRX SCL SDA ex Switches LED Status Information LED Continuously ON OFF Flashing 5V Normal 5V supply OK 5 V Power Supply Failure N A 5V Normal 5V supply OK 5 V Power Supply Failure N A Error Error Gateway software not running Normal Software cleared during operation Error Software constantly rebooting Watchdog ...

Page 17: ...ent of rear panels Any vacant slots must have a blank rear panel fitted Configuration Rules These rules limit the total power dissipation of modules that can be installed in the box Use the module power ratings to calculate the total power dissipated in the enclosure Module Power Rating The power rating for each module is given in its associated operation manual Available Power The IQH1S Enclosure...

Page 18: ...ear of the enclosure in the vacant aperture and secure with the fixing screws provided 9 At the front of the enclosure ensuring correct orientation carefully slide in the new module until it fully mates with the rear connector panel 10 Slide the module retaining plate upwards or downwards as appropriate to cover the card entry slots 11 Tighten the screw securing the module retaining plate 12 Repla...

Page 19: ...unique feature ensures that module updates or additions will not require control system software upgrades simply plug in and switch on For modules with the RollCall option fitted all card edge control functions are available on the remote control panel or any other controlling device For some module cards additional control functions and readouts will be available to the RollCall panel but will no...

Page 20: ...4 networks containing up to a total of 208 million 3840 16 x 54241 IQ modules The RollCall network has three interface connections on each IQ enclosure 1 75 Ohm coaxial BNC for box to box connections running at 2 5 Mb s 2 RS485 9 way D connector for internal bus connections such as to front panels running at 2 5 Mb s 3 38 4 Kb s asynchronous RS422 port for binary and ASCII terminal access for thir...

Page 21: ...485 bus is still 255 nodes and the total network length can be up to 1500m The maximum number of hub transitions between any number of nodes is 6 OK Not OK 75 Ohm Coaxial Interface This interface allows connections of units to a single section of 75 Ohm video cable Each unit is physically joined via a T piece connector Each end of the section is terminated by a 75 Ohm resistor at each end of the c...

Page 22: ...an provide a natural hub between coaxial sections Example configuration RS422 Asynchronous Interface This interface is specifically designed for third party connections into the system and runs at 38 4 Kb s This allows PC s or any other serial device access to any of the units within the system Every active 1U or 3U box has one of these ports The port operates in binary mode formatted packet data ...

Page 23: ... or combinations of both fitted horizontally Module card dimensions 100 mm wide 340 mm long Module rear connector 64 way Module rear panel dimensions 103 4 mm wide 40 4 mm double width 20 mm single width high CE Performance Information Environment Commercial and light industrial E2 Peak Mains Inrush Current following a 5 second mains interruption 18 7 A peak at 0 Power Input Voltage Range 100 240 ...

Page 24: ...6 www snellwilcox com Snell Wilcox Ltd Southleigh Park House Eastleigh Road Havant Hants PO9 2PE United Kingdom For General Enquiry s contact Tel 44 0 2392 489000 Fax 44 0 23 9245 1411 For Technical assistance contact Tel 44 0 2392 489058 Fax 44 0 2392 489057 Web http www snellwilcox com support Ftp ftp ftp snellwilcox com support ...

Page 25: ...of electric shock do not expose this appliance to rain or moisture Always ensure that the unit is properly earthed and power connections correctly made This equipment must be supplied from a power system providing a PROTECTIVE EARTH connection and having a neutral connection which can be reliably identified The power outlet supplying power to the unit should be close to the unit and easily accessi...

Page 26: ...ARILLO conectado a E Conductor de protección a Tierra Earth en el original AZUL conectado a N Conductor Neutro Neutral en el original MARRÓN conectado a L Conductor Fase Live en el original RIESGO DE CHOQUE ELECTRICO NO QUITAR LAS PROTECCIONNES ELEMENTOS NO ACCESIBLES AL USUARIO SERVICIO SOLAMENTE A PERSONAL CUALIFICADO Simboli di sicurezza Questo simbolo indica l informazione importante contenuta...

Page 27: ...avissa Sähköpistorasian tulee olla laitteen lähellä ja helposti tavoitettavissa Sähkökytkentä Laitteen vakiovarusteena on sähköjohto jonka toisessa päässä on muottiin valettu IEC standardin mukainen liitäntärasia ja toisessa päässä muottiin valettu IEC standardin mukainen pistoliitin Jos pistoliitin tarvitsee poistaa se tulee hävittää heti turvallisella tavalla Johtimet kytketään seuraavasti KELTA...

Page 28: ... follows GREEN lead connected to E Protective Earth Conductor BLACK lead connected to L Live Conductor WHITE lead connected to N Neutral Conductor For products with more than one power supply inlet Caution To reduce the risk of electric shock plug each power supply cord into separate branch circuits employing separate service grounds CAUTION This equipment contains a lithium battery There is a dan...

Page 29: ...rt 15 Class A 1998 EMC Environment The product s described in this manual conform to the EMC requirements for and are intended for use in the commercial and light industrial environment including for example theatres E2 EMC Performance Information Please refer to the Technical Profile Specifications section of the product operation manual EMC Performance of Cables and Connectors Snell Wilcox produ...

Page 30: ...ght protection claimed includes all forms and matters of copyrightable material and information now allowed by statutory or judicial law or hereinafter granted including without limitation material generated from the software programs which are displayed on the screen such as icons screen display looks etc Reproduction or disassembly of embedded computer programs or algorithms prohibited Copyright...

Page 31: ...f switch 3 1 Front panel connector 3 1 Communications mode switch 3 1 Communication connections 3 2 The Gateway card 3 3 Front panel connector 3 3 Communications mode switch 3 3 Hex switches 3 3 LED indicators 3 4 Control Panels 3 5 The RollCall Communications System and Computer Control System 3 5 RollCall Network System Details 3 6 RollNet RS485 Differential Interface 3 7 75 Ohm Coaxial Interfac...

Page 32: ...nu System 4 8 SETUP MENU SYSTEM 4 9 Front Panel Setup via the RollCall Control Templates 4 14 Control 4 14 Setup 4 16 RollCall Control Templates for the IQHS1U Enclosure RCIF 4 17 Control 4 17 Slots 4 19 Setup 4 22 Log Server 4 25 Logging 4 26 Logging Fields 4 27 Statistics 4 29 IQH1S Enclosure RCIF Setup via the Front Panel Menu System 4 30 GENERAL INFORMATION 4 31 RCIF Menu Details 4 31 Slots 4 ...

Page 33: ... are being monitored System Please provide a brief description of the system in which your S W equipment is currently being used Basic Tests Preset Unit Please use the Preset Unit function to return the settings back to the factory default RollCall Is your unit currently connected to a RollCall capable PC This software is obtainable for free and provides a very user friendly GUI for virtually all ...

Page 34: ... Product Type Video Products i e Modular Kudos Plus and Alchemist Unit Serial Number Fault Spare Part Information please advise us how many units show this fault and the system layout showing all other manufacturers products e mail Preferred Method of Contact Phone Item is required Please mail to Snell Wilcox Ltd Southleigh Park House Eastleigh Road Havant Hants PO9 2PE United Kingdom Service Cont...

Page 35: ...e 4 0 12 Manual Revision Record Date Version No Issue No Change Comments 030403 1 1 First issue released 090605 1 2 Power to 60 W page 2 1 Updated section 4 New issue released 041006 1 3 For new software New issue released 231106 1 4 Page 3 4 LED status data added New issue released ...

Page 36: ...xample of the rear of a 1U Mainframe fitted with six single width Modules Fuse ROLLCALL 100 240V 60 50 Hz 1 8A T T2A H 250V IQDSDR 1 SERIAL OUTPUT 2 SERIAL IN 1 3 4 5 2 IQDCO 1 GPI I O 1 2 3 B OUT A IQDDAC 1 COMPONENT OUTPUT 2 SERIAL IN SYNC OUT G Y B Pb R Pr SERIAL OUT IQDCO 1 GPI I O 1 2 3 B OUT A IQDMX0 1 _16 2 AES AUDIO OUT 1 2 SERIAL IN 1 SERIAL OUT REFERENCE GPI SERIAL IN 2 Features 1RU rack...

Page 37: ...or combinations of both fitted horizontally Module card dimensions 100 mm wide 340 mm long Module rear connector 64 way Module rear panel dimensions 103 4 mm wide 40 4 mm double width 20 mm single width high CE Performance Information Environment Commercial and light industrial E2 Peak Mains Inrush Current following a 5 second mains interruption 18 7 A peak at 0 Power Input Voltage Range 100 240 V...

Page 38: ...NECTIONS This is the IEC320 mains power connector suitable for a standard IEC type power cable and contains a 2A T HBC 250 V fuse If a fused type plug is fitted to the cable a fuse of 7A rating should be installed POWER ON OFF SWITCH The power ON OFF switch is located behind the drop down front panel in the left hand corner Power ON will be indicated by the illumination of the LED on the front pan...

Page 39: ...manner to an Ethernet system Both extremities of the system must be terminated in 75 Ohms Note that in a RollCall segment all units must have different unit address codes Note The coaxial link is bi directional and therefore must not be passed through signal switching networks Also to allow hum and noise cancellation the screen of the coaxial connection must not be earthed 100 240V 60 50 Hz 1 8A T...

Page 40: ... on these switches may be used to set the Unit Address in Hex Left hand switch 1 to f right hand switch 0 to f If an address is already in use the RollCall receive and transmit LED s will flash alternately at a 1 second rate The unit must then be powered down a unique address selected and the unit powered up again Note that the Shoebox active front panel has a separate and different address to the...

Page 41: ...data is being transmitted via the RS422 connection 4 7 8 2 4 7 8 5V 5V Error STX SRX NTX NRX SCL SDA ex Switches LED Status Information LED Continuously ON OFF Flashing 5V Normal 5V supply OK 5 V Power Supply Failure N A 5V Normal 5V supply OK 5 V Power Supply Failure N A Error Error Gateway software not running Normal Software cleared during operation Error Software constantly rebooting Watchdog ...

Page 42: ...unique feature ensures that module updates or additions will not require control system software upgrades simply plug in and switch on For modules with the RollCall option fitted all card edge control functions are available on the remote control panel or any other controlling device For some module cards additional control functions and readouts will be available to the RollCall panel but will no...

Page 43: ...4 networks containing up to a total of 208 million 3840 16 x 54241 IQ modules The RollCall network has three interface connections on each IQ enclosure 1 75 Ohm coaxial BNC for box to box connections running at 2 5 Mb s 2 RS485 9 way D connector for internal bus connections such as to front panels running at 2 5 Mb s 3 38 4 Kb s asynchronous RS422 port for binary and ASCII terminal access for thir...

Page 44: ...485 bus is still 255 nodes and the total network length can be up to 1500m The maximum number of hub transitions between any number of nodes is 6 OK Not OK 75 Ohm Coaxial Interface This interface allows connections of units to a single section of 75 Ohm video cable Each unit is physically joined via a T piece connector Each end of the section is terminated by a 75 Ohm resistor at each end of the c...

Page 45: ...an provide a natural hub between coaxial sections Example configuration RS422 Asynchronous Interface This interface is specifically designed for third party connections into the system and runs at 38 4 Kb s This allows PC s or any other serial device access to any of the units within the system Every active 1U or 3U box has one of these ports The port operates in binary mode formatted packet data ...

Page 46: ...the current status of the controlled module and other information messages e g error comments warnings etc The Control display contains the names of the lower level menus that may be scrolled through using the spinwheel The sub menu may be then be selected by pressing the push button adjacent to the arrowhead in the text line of the menu name This sub menu will then be displayed in the window and ...

Page 47: ...s The selection is made by pressing the button adjacent to the required item SYMBOLS Symbols used in this window have the following meanings These symbols to the right or left of text indicate that the item may be selected Pressing the button adjacent to this symbol selects the menu item When three dots periods follow an item it indicates that more sub menus are available under this item ...

Page 48: ...s for the Gateway and or the front panel If this occurs a warning will be given and the offending address should be changed The Gateway address can be changed using the hex switches see section 3 page 3 and the front panel address via the Setup menu The MODULES button should then be pressed and will become illuminated A list of locations and their status see SYMBOLS will then be displayed in a lis...

Page 49: ...ontinuously or flashes intermittently the network is unstable This would indicate broken cabling missing termination etc Dedicated Push Buttons Various specific operations may be carried out by using these push buttons When pressed the button LED will become illuminated indicating that the function is active Pressing the button again deactivates the function and the button LED will turn off MODULE...

Page 50: ...ndow Pushing the button adjacent to the error message will clear it from the list If there are no errors the window will display No Warnings LOCK Pressing this button enables a selected module to be locked or unlocked to the control panel This function will only be available for a unit that is already connected to the front panel Other modules may be still be connected to and controlled by the con...

Page 51: ...dot 1st set The version of the control unit 2nd set Variant of software version 3rd set Control compatibility version number The fourth line will display system save codes 2 Current selections and conditions First Line Unit Name This line shows the name of the unit If the name has been changed in the Unit Name Menu the new name will appear here Second line Signal s input status Third Line Status o...

Page 52: ...nframe The active front panel may communicate to either of the following Modular cards contained within the local mainframe The RollCall network via BNC Connector PC via 9 pin D connector for RS422 or RollCall 485 Operation uses a system of menus displayed in two LCD windows on the active front panel Menu items are selected by push buttons and further menu selections made by rotating a spinwheel a...

Page 53: ...e Lock Controls Save Auto Connect 03 Name 0000 32 00 Clear Auto Connect Access Level USER Engineer Supervisor Save Access Level Save 0000 32 00 Clear Min Unit Address Save 0000 32 00 Clear Max Unit Address Software Version 7 0 9 OK Software Version 0000 Clear Preset Save Set Password MAIN MENU Supervisor Level F Panel Address F Panel Name Auto Connect Default Unit Backlight Network Min Unit Addr M...

Page 54: ...Note that all these sub menus include a SAVE function that is used to save particular settings If the changed settings do not need to be saved use the RETURN function to return to the previous menu this action will abandon any changes and revert to the previously saved settings F Panel Address The address of this control panel will be displayed as a 2 digit hexadecimal code Unit Address FF Hex Sav...

Page 55: ...is action also removes the unit name from the display and inserts a symbol indicating that no unit will be connected to this session The Auto Connect set up may be saved by pressing either the dedicated front panel Save button or by pressing the button adjacent to the Save display text Auto Connect The Auto Connect menu allows a number of units to be automatically connected to the control panel at...

Page 56: ...numbers in the Auto Connect set up a will appear in the second line of text Also when the numbers are selected in rotation the word None will appear after Default Unit when the number 15 is exceeded This confirms that no units have been assigned a number Note that only one unit may be designated as the default unit BackLight Backlight Mode AUTO Save Backlight Selecting this function allows the bac...

Page 57: ...maximum of 200 addresses The Min and Max Unit Addr Address function allows a range of addresses to be configured for partial use of the network Save 0000 32 00 Clear Min Unit Address The Min Unit Addr selection sets the minimum address Save 0000 32 00 Clear Max Unit Address The Max Unit Addr selection sets the maximum address The overall range of addresses is from 1 to 255 Lock Controls To set thi...

Page 58: ...he default password will be 0000 To change the password select the line for digits 1 2 3 and 4 and using the spinwheel to select the desired characters Note that only numbers in the rage of 1 to 8 may be used 0 and 9 cannot be used Press Save The password has now been set Selection levels are USER Provides access to basic user controls ENGINEER Provides access to more controls than at user level b...

Page 59: ...ress code is user defined in the range 1 0 to F F Use the scrollbar to select the desired code Minimum Maximum Address Range The front panel can only hold a maximum of 200 addresses The Min and Max Unit Addr Address function allows a range of addresses to be configured for partial use of the network The Minimum Address Range selection sets the minimum address The Maximum Address Range selection se...

Page 60: ...The first set is the network address the second set is the physical unit address and the third set is the port address The code may be changed by typing in the new code The code may be reset to 0000 00 00 by pressing the button This action also removes the unit name from the display and inserts a symbol indicating that no unit will be connected to this session The Auto Connect set up may be saved ...

Page 61: ... make a connection to that unit Selecting return will return the RollCall unit address to 0000 00 00 Supervisor Password 1 8 The 4 digit supervisor password may entered here Note that only numbers in the rage of 1 to 8 may be used 0 and 9 cannot be used Selecting return will save the new password The preset selection sets the password to 0000 Lock Controls When enabled the front panel controls wil...

Page 62: ... checked the packet counts will be updated When unchecked the packet counts the packet counts will be replaced with dashes Note that the packets are still counted while Update Packet Stats is disabled When enabled the Gateway will display current totals they will not restart from zero When selected this item will reset all of the packet counters to zero Show Session This controls which client is d...

Page 63: ...d to scroll through the connected controllers Packet counts from this controller and from all connected controllers are displayed to the right Blind This will display the address of last controller to send the module a blind control packet Packet counts from blind controllers is shown to the right Allow Blind Control If the module will be controlled by Blind Control RollTrack and some third party ...

Page 64: ...is entry is edited the current Installed Unit ID gets copied to the Bound Type ID This function also has the advantage that names and types may be setup before delivery The symbol represents the Preset function and will return the name to the installed name and the ID to the installed ID Selecting the symbol will save the new name and ID Bound Type ID The Bound Type function allows the slot to be ...

Page 65: ... the Installed Unit Name widow will show No Unit Fitted and the Installed Unit ID window will show No Unit Correct Module Fitted If a module is fitted that matches the bound type then the editable name is used in the network browser In the absence of other modules the Gateway will log Module Status as OK and show Module Status OK on the Logging Page The gateway also logs MSG UNIT PRESENT for the s...

Page 66: ...e Fitted If a module is fitted that does not match the bound type then the editable name will not be used and the generic type and slot number will appear in the network browser Correct Module Fitted If a module is fitted that does match the bound type then the editable name is used in the network browser ...

Page 67: ...fore the main application runs Menu Caches Module The Gateway caches module menu sets locally to improve menu upload speeds In rare circumstances this may cause problems If problems with module menu uploads are encountered the menu caches can be cleared or caching disabled Format Now This deletes the existing module menu caches The caches will be recreated when the next menu client connects Enable...

Page 68: ...f upgrading the gateway software you must enable Blind Control Box Type This item allows the 1U enclosure to be configured as a ShoeBox or a 3U Box Note that when the ShoeBox and 3U selections are made the templates will be different and some items will only be usable if the 1U enclosure is controlling the selected box type Where Am I This allows the 1U enclosure to be physically located in a larg...

Page 69: ...Pass I_AM Serial and Pass I_AM IP So if Pass I_AM Bridge is set I AM messages will be passed over the bridge irrespective of how the other controls are set SP_TIME This controls whether the Gateway passes wide area TIME packets from the serial port to the RollCall Network Normally this is enabled to allow PCs attached to the serial port to be time servers but it may be disabled if you wish to cont...

Page 70: ...the name is case sensitive Any LogServer If this item is checked Logging information will be sent to any Logger on the system It is suggested that if there is only one server on the system this option should be chosen Using This displays the name and RollCall address of the current Log Server If the Gateway does not have a logserver this will show No Active Logger Accept Logserver via RollNet If t...

Page 71: ...IQH1S IU Enclosure SECTION 4 IQH1SOPS 23 11 06 www snellwilcox com Version 1 Issue 4 4 26 Logging This menu determines the information made available for logging ...

Page 72: ...nternal fault status of unit NONE FAIL fault description This field is used to report internal hardware or software faults detected by a unit as distinct from external error conditions e g loss of input RECON_STATE OK Warn Fail 0 RollNet reconnections in last 10 seconds 1 Rollnet reconnection in last 10 seconds 1 RollNet reconnection in last 10 seconds UPTIME Uptime in seconds Number DDD HH MM SS ...

Page 73: ...les this bus is I2c VOLTAGE_1_NAME VOLTAGE_2_NAME Voltage rail name Text For IQ these are 7 5V 7 5V rails VOLTAGE_1_STATE VOLTAGE_2_STATE Is the voltage rail within spec OK FAIL High FAIL Low Voltage rail is within spec Absolute value of voltage rail is above normal operating threshold Absolute value of voltage rail is below normal operating threshold This definition means that if the 7V rail is a...

Page 74: ...cting this function will reset all statistics to zero Recons This item indicates any errors occurring during the communication of connection data in the Rollcall network Condition Error value Normal 0 or constant value Fault Value increases at an unacceptable rate Errors occur on a regular basis Possible Faults Faulty T piece or cable Missing termination s Incorrect value of termination s Clash of...

Page 75: ...n OK Seial Number Xxxxxxxx Serial Number Build Number Build Number 0045601367 OK Loader Version Loader Version 2 9 6 OK Logging Disabled Named LogServer Any LogServer Log to Log to LogServer Name Cur Logger Cur Logger Addr Last Time addr Time from Logger Accept via Serial Accept via RollNet Log Server Log Values Log Values OK LOW OK Log Server SN VERSION Log OS Version OS_VERSION Log Build Number ...

Page 76: ...led The main or top level menu allows various sub menus to be selected by pressing the button adjacent to the required text line Note that where a menu item is followed by three dots this indicates that a further sub menu may be selected Whenever a menu item is selected the parameters of that selection will be displayed in the Information window of the front panel Where the selection is purely a m...

Page 77: ...nction loads the default name text O K saves the text and returns to the previous menu Bound Type The Bound Type function allows the slot to be associated with a particular type of module e g a encoder type 284 Bound Type None Preset Bound Type If a module matching this type ID is fitted the Gateway will use the user given name If an incorrect card type is installed in the slot the RollCall ID wil...

Page 78: ... available for logging Log Server SN VERSION Log OS Version OS_VERSION Log Build Number BUILD_NUMBER Log Hardware Ver HARDWARE_VERSION Log Module Status MODULE_STATUS Log Gway Ctrl Sess SESSIONS Log Last Modified LAST_MODIFIED Log Temp 1 Name TEMP_1_NAME Log Temp 1 State TEMP_1_STATE Log Temp 1 Celsius TEMP_1_CELSIUS Log Voltage 1 Name VOLTAGE_1_NAME Log Voltage 1 State VOLTAGE_1_STATE Log Voltage...

Page 79: ...is suggested that if there is only one server on the system this option should be chosen LogServer Name The Logging Server to be used may be named by editing the text string in the text window Cur Logger This displays the name of the current Log Server If the Gateway does not have a logserver this will show No Active Logger Cur Logger Addr This displays the RollCall address of the current Log Serv...

Page 80: ...re version Software Version Software Version OK This shows the software version installed Build Number Build Number Build Number 0045601367 OK This shows the software build number of the unit Loader Version Loader Version Loader Version 2 9 6 OK This shows the version of the gateway software loader The loader operates at start up only validating all gateway files before the main application runs N...

Page 81: ... RCIF3U2Y 00X Serial Mode Pass I_AM Serial This controls whether the Gateway passes wide area I_AM packets from the serial port to the RollCall Network Normally this is enabled to allow PCs attached to the serial port to be located by other units but it may be disabled if you wish to control the flow of I_AM packets through a system NB Pass I_AM Bridge overrides both Pass I_AM Serial and Pass I_AM...

Page 82: ...t 6 Pkt Stats Control Any of the 6 slots may be interrogated and the following information displayed Allow Blind Control Single Session Only Controller Last Blind User Con Pkt Count Con Pkt Total Blind PKT Count Disconnect Session Slot 1 to 6 Allow Blind Control If the module will be controlled by Blind Control RollTrack and some third party remote control systems then Allow Blind must be enabled ...

Page 83: ... packets of the blind controller address Blind Pkt Count 43690 Preset Blind Pkt Count Show Session This controls which client is displayed by the other Control menu items Show Session 14 Preset Show Session Packet Statistics When the modules receive commands from control clients the number of commands are counted Update Packet Stats Clear Packet Counts Packet Statistics Update Packet Stats When se...

Page 84: ...r 0045601367 OK Loader Version Loader Version 2 9 6 OK Logging Disabled Named LogServer Any LogServer Log to Log to LogServer Name Cur Logger Cur Logger Addr Last Time addr Time from Logger Accept via Serial Accept via RollNet Log Server Log Server SN VERSION Log OS Version OS_VERSION Log Build Number BUILD_NUMBER Log Hardware Ver HARDWARE_VERSION Log Module Status MODULE_STATUS Log Gway Ctrl Sess...

Reviews: