TBS100/100D
SECTION 4
TBS100OPS
20/10/06
www.snellwilcox.com
Version 2 Issue 5
4.13
◀
◀
◀
◀
GPI
The GPI connection may be configured as an input
(from mechanical switch contacts, relay contacts
etc.) as an output or be completely disabled.
These configurations may be setup using this
menu.
GPI
GPI Input Enable
GPI Input Setup...
GPI Output Enable
GPI Output Setup...
GPI Input Enable
Selecting the GPI Function
Function
Selection
Disabled
GPI Input Enable
Configured as an Input
GPI Input Enable
Disabled
GPI Output Enable
Configured as an Output
GPI Output Enable
Note that the GPI may be configured as an input
or
as an output but not as both; however it may be
disabled as an input
and
disabled as an output.
◀
◀
◀
◀
GPI Input Setup
When configured as an input the unit the GPI will
respond to either a closed to open transition (Open)
or an open to closed transition (Close).
GPI Open...
GPI Close...
GPI Input Setup
This item allows these two functions to be selected.
◀
◀
◀
◀
GPI Open/GPI Close
GPI Open/Close
Off
Pattern On
Pattern Off
Freeze On
Freeze Off
Memory 1
Memory 2
Memory 3
Off
The resulting action that the unit takes on receipt of
a valid GPI input may be selected from this menu.
◀
Off
When this item is selected no action will occur.
◀
Pattern On
On receipt of a valid GPI input the output will
become the pattern that has been selected via the
Pattern menu.
◀
Pattern Off
On receipt of a valid GPI input the pattern signal will
be turned Off.
◀
Freeze On
On receipt of a valid GPI input the output will
become a frozen picture.
◀
Freeze Off
On receipt of a valid GPI input the output picture will
become unfrozen.
◀
Memory 1, 2, 3
One of the three memory locations may be
selected. On receipt of a valid GPI input the settings
stored in the selected memory location will recalled.
◀
◀
◀
◀
GPI Output Setup
When the GPI is configured as an output the unit
will produce an output signal.
GPI Output Setup
Delay Flag
High On Input Loss
Low On Input Loss
Input Line Std 625
Input Line Std 525
Input Line Std 625
This item allows the type of output signal to be
selected.
◀
◀
◀
◀
Delay Flag
When enabled the output will represent the
input/output time delay through the unit.
◀
◀
◀
◀
High On Input Loss
When enabled the output will become high when a
loss of the selected input signal occurs.
◀
◀
◀
◀
Low On Input Loss
When enabled the output will become low when a
loss of the selected input signal occurs.
◀
◀
◀
◀
Input Line Std 625/525
The GPI output will become high to indicate the
selected input line standard.