RollTrack 1-4, RollTrack 5-8
This function allows the value of the delay time
produced by this module to be sent, via the
RollCall™ network, to audio delay units connected
on the same network. This enables compatible
audio delay units to produce an audio delay
dependent on this and other similar units. The
audio delay unit will dynamically follow or track the
received delay-time information allowing processed
video signals to be timed correctly with audio
signals. This automatic tracking system via the
RollCall™ network is call
RollTrack
.
For more detailed information, see the RollTrack
section (Appendix) at the end of this manual.
The destination for the delay information is set by
the network code address as follows:
Unit 1-8
This item allows the address of the selected
destination unit to be set.
To change the address, type the new destination in
the text area and then select
(return)
(Preset) returns to the default destination
For details of the RollCall command numbers for
specific units please contact your local Snell &
Wilcox agent.
The full network address has five sets of numbers.
For example: 0000:10:01*14*51
The first set (0000) is the network segment code
number
The second set (10) is the number identifying the
(enclosure/mainframe) unit
The third set (01) is the slot number in the unit
The fourth set (14) separated by an * is the
channel number.
Note that only channel numbers 14, 15, 16 & 17
should be used for audio delay cards.
The fifth set (51) is the board type identification.
Once a destination address for a unit has been set