TBS100/100D
SECTION 4
TBS100OPS
20/10/06
www.snellwilcox.com
Version 2 Issue 5
4.30
GPI
This screen allows the GPI to be configured as and
its action defined.
GPI Input Setup
When configured as an input the GPI connection
may be used for accepting GPI information (from
mechanical switch contacts, relay contacts etc.)
The resulting action that the unit takes may be
selected using this item.
Input Enable
When selected the GPI connection will be
configured as an Input.
Note that this function will toggle with the Output
Enable function.
GPI Input Open
This function determines what happens when the
selected GPI input condition changes from closed
to open.
Off
No action
Pattern
On
The output will become the
selected pattern signal.
Pattern Off
The output will become the normal
output signal.
Freeze On
The output will become a frozen
picture.
Freeze Off
The output will become unfrozen
and return to normal.
Memory 1 to 3 The unit will revert to the setup
stored in the selected memory
location
GPI Input Close
This function determines what happens when the
selected GPI input condition changes from open to
closed.
Off
No action
Pattern
On
The output will become the
selected pattern signal.
Pattern Off
The output will become the normal
output signal.
Freeze On
The output will become a frozen
picture.
Freeze Off
The output will become unfrozen
and return to normal.
Memory 1 to 3 The unit will revert to the setup
stored in the selected memory
location