TBS100/100D
SECTION 4
TBS100OPS
20/10/06
www.snellwilcox.com
Version 2 Issue 5
4.34
Help
Information Window Definitions
This area will show abbreviated data about the
status of the unit.
Abbreviations used are as follows:
First Line
Item 1:
In
(Input Selection)
In: CVBS A
Composite input A selected.
In: CVBS B
Composite input B selected.
In: YC
YC input elected.
Item 2:Detected input signal standard
***
No input or invalid signal detected
525
Input is a 525 line monochrome signal
625
Input is a 625 line monochrome signal
PAL
Input is a PAL composite signal
PALN
Input is a PAL-N composite signal
SECAM
Input is a SECAM composite signal
NTSC
Input is a NTSC composite signal
NTSCJ
Input is a NTSC-J composite signal
PALM
Input is a PAL-M composite signal
Second Line
Item 1
Ou\\\\snellwilcox.local\\root\\Marketing\\Prodmg
mt\\Data
(Encoder output signal standard
)
PAL
Output is a PAL composite signal
PALN
Output is a PAL-N composite signal
SECAM
Output is a SECAM composite signal
NTSC
Output is a NTSC composite signal
NTSCJ
Output is a NTSC-J composite signal
PALM
Output is a PAL-M composite signal
Item 2
Ref:
(Reference signal information)
OK
Reference signal is valid the unit is
genlocked.
Error
A reference signal error or no reference
has been detected while trying to genlock.
***
No reference or invalid reference
Off
Genlock is Off
Third Line
The third line will show the status of the output
signal and the state of the ProcAmp controls.
Item 1 (Output Signal)
(Nothing) Output is processed picture.
Pattern
Output is a pattern
Freeze
Output is a frozen picture
Note that if Pattern or Freeze has been forced
because of an input signal failure the words will be
prefixed by an asterisk e.g
*
Pattern
or
*
Freeze
.
Item 2 (ProcAmp Controls)
The word
Uncal
will be displayed if the ProcAmp
controls are not at their preset values.