TBS100/100D
SECTION 4
TBS100OPS
20/10/06
www.snellwilcox.com
Version 2 Issue 5
4.35
Operation via Card Edge Controls
The unit will respond simultaneously to either
remote RollCall commands or card-edge control
settings one system overriding the settings of the
other.
For cards using the RollCall™ remote control
system, activating these switches will override the
remote control settings. The RollCall™ control
panel will then follow these settings.
The current settings are saved in an on-board
memory.
If the remote link (LK1) is fitted the saved control
settings are used when the unit is powered-up.
If the remote link (LK1) is not fitted the unit will take
its control settings from the card edge switches
where possible and otherwise will use the default
settings.
LED INDICATORS
+5V and -5V
When illuminated these LED’s indicate that the
+5 V and -5 V supplies are present.
No Input
The
No I/P
LED will be continuously illuminated
when the unit is not receiving an input signal.
Ref Loss
This LED will be illuminated if the unit is not
receiving a valid Reference signal.
Input Error
This LED will flash if the unit is receiving an invalid
input signal.