The IQH3A 3U Enclosure is provided with one PSU as standard. There is an option for
installing a second PSU to allow dual redundant operation. This may be a factory fitted option
or can be done as an upgrade.
When installing a second PSU ensure that the blanking plate is kept in the storage position.
3.12.1 Installing a Power Supply Unit
3.12.2 Removing a Power Supply Unit
To remove a power supply unit:
1.
Open the front panel, as described in section 3.7 on page 22.
2.
Release the securing screw.
3.
Pull handle firmly and slide out the power supply.
4.
Fit new PSU or blanking plate.
5.
Tighten securing screw.
6.
Refit the front panel.
Ensure that the power supply is switched OFF and the mains power connection at the rear
of the unit is removed before these operations are attempted.
When a single PSU is used the second PSU slot must always have the blanking plate
fitted. Operating the equipment without this may result in damage to the equipment.
To install a power supply unit:
1.
Open the front panel, as described in
section 3.7 on page 22.
2.
If necessary, remove PSU blanking
plate and replace in the storage
position on the inside of the front
panel.
3.
Ensure the power supply's
orientation is correct.
4.
Slide power supply in and push home
firmly.
5.
Tighten securing screw.
6.
Refit the front panel.