4.5 Log Server
This
Log Server
screen enables the characteristics of the logging server to be specified.
4.5.1 LogServer
The Logging Server to be used may be named by editing the text string in the text window. To
enter/modify the name of the logging server, enter the new name in the editable text field and
click the Save (
S
) button. To restore the default value, click the Preset (
P
) button.
4.5.2 Logging Disabled
If this item is checked the Logging function will be disabled.
4.5.3 Named LogServer
If this item is checked Logging information will only be sent to the server named in the name
window. Note: matching of the name is case sensitive.
4.5.4 Any LogServer
If this item is checked Logging information will be sent to any Logger on the system.
It is suggested that if there is only one server on the system, this option should be chosen.
4.5.5 Using
This displays the name and RollCall address of the current Log Server. If the Gateway does
not have a logserver this will show “No Active Logger”.
4.5.6 Accept logserver via RollNet
If this is selected, the Gateway will accept servers packets via the RollNet port.
4.5.7 Accept logserver via IP
If this is selected, the Gateway will accept servers packets via the IP port.