4.6.6 Examples of Slot Use
4.6.6.1
Intentionally Empty Slot
If a slot is intentionally left empty, the Installed Unit Name field will show
No Unit Fitted
and
the Installed Unit ID field will show
No Unit
.
The Editable Name field will be empty and the Bound Type ID widow will display
None
.
In the absence of other modules, the Gateway does not log Module Status for this slot
position.
4.6.6.2
Correct Module Fitted
If a module is fitted that matches the Bound Type, the Editable Name is used in the network
browser.
In the absence of other modules, the Gateway will log Module Status as
OK
, and display
Module Status = OK on the
Logging
screen. The Gateway also logs MSG=UNIT PRESENT
for the slot position.
4.6.6.3
Module Absent - Unit Bound
If a slot is intended to have a particular module fitted (as set by the Bound Unit function) but
no module is fitted,. the Installed Unit Name field will display
No Unit Fitted
and the Installed
Unit ID field will display
No Unit
. However, the Editable Name field will show the intended
name and the Bound Type ID field will display the intended ID.
In the absence of other modules the Gateway will log Module Status as 1 Module Missing,
and show Module Status = 1 Module Missing on the
Logging
screen. The gateway also logs
MSG=UNIT LOST for the slot position.
4.6.6.4
Module Fitted - No Bound Unit
If a module is fitted in a slot but no Bound Type is assigned to this slot, the generic type name
for the module type will be displayed and the slot will appear in the network browser by its slot
number and generic type.
In the absence of other modules the Gateway will log Module Status as 1 Extra Module and
show Module Status = 1 Extra Module on the
Logging
screen. The Gateway also logs
MSG=UNIT PRESENT for the slot position.
4.6.6.5
Incorrect Module Fitted
If a module is fitted that does not match the Bound Type, the Editable Name will not be used
and the generic type and slot number will appear in the network browser.
In the absence of other modules, the Gateway will log Module Status as 1 Wrong Module,
and show Module Status = 1 Wrong Module on the
Logging
screen. The gateway also logs
MSG=UNIT PRESENT for the slot position.
4.6.6.6
Non-RollCall Module Fitted
If a card that is passive to RollCall is fitted in a slot, select the Non RollCall Enable check box.
The Gateway will simulate a RollCall compatible card in the relevant slot, and raise
awareness to RollLog and RollMap. In the IDNAME field, enter a name for the unit so that it
can be recognized.
For the module, the Gateway will log MSG=NON ROLLCALLMODULE, and IDNAME=<user
defined>.