IQH3A IQ 3U Modular Enclosure
www.snellgroup.com
Operation
Issue 2 Rev 2
Page 55
©
2014 Snell Limited
4.7 Control (1-8) and (9-16)
The
Control
screens display information about the controllers for each slot.
4.7.1 Update Packet Stats
When the modules receive commands from control clients the number of commands are
counted. If the
Update Packet Stats
box is checked, the number of control packets from the
currently selected connected controller and from all connected controllers is shown to the
right of the controller address. The number of blind control packets is shown to the right of the
blind controller address.
If the
Update Packet Stats
box is unchecked, the packet counts will be replaced with dashes
(-).
4.7.2 Clear Packet Counts
When the
Clear Packet Counts
button is clicked, clicked, all packet counters will be reset to
zero.
Note:
The packets are still counted while Update Packet Stats is disabled. When enabled, the
Gateway will display current totals; they will not restart from zero.