IQH3A IQ 3U Modular Enclosure
www.snellgroup.com
Operation
Issue 2 Rev 2
Page 61
©
2014 Snell Limited
4.10 Logging 1
The
Logging 1
screen shows the information made available via RollCall logging, and allows
the user to specify which fields will be logged.
Each log field is shown on a separate line. Each has an enable check box, a descriptive
name, the log field header and the current value.
The only exceptions are Serial Number and Software Version, which are always logged and
therefore have no enable check box.
When the check box is checked, that field will be logged to the logserver.
Field Name
Field Name Description
Valid Field Values
Usage Description
SN
Serial Number
Serial Number
Format is standard S&W serial number
consisting of character “S” followed by
eight digits, e.g. “S12345678”
VERSION
Software Version
Software Version Number
Eg. 5.18.18
BUILD_NUMBER
Build Number
Text
For K_OS-based units, this is typically
a ten-digit string, e.g. “0123456789”.
Future units may use a different format.
OS_VERSION
OS Version
OS Name & Version
Format: “<OS String> <Version
String>”, e.g. “KOS V115”
HARDWARE_VERSION
Hardware Version
Version Number
Format: “<PCB name>/<mod strike>”,
eg “RCIF3U2Y/2”