IQMDA00

SECTION N1

IQMDA00OPS 090305

www.snellwilcox.com

Version 1 Issue 2

N1.12

RollTrack (continued)

RollTrack Sending

This item shows when the unit is actively sending
the RollTrack command.

This may show:

String

A string value is always being sent.

Number

A number value is always being sent.

No 

The message is not being sent.

Yes 

The message is being sent.

Internal Type Error

Inconsistent behavior; please contact your local
Snell & Wilcox agent.

RollTrack Status

This item will show the status of the RollTrack
system.

For details of the RollCall command values for
specific units please contact your local Snell &
Wilcox agent.

Summary of Contents for IQMDA00

Page 1: ...nitoring Output options include 4 x HD SDI and 3 x SD SDI One group of audio can also be carried through from the HD inputs to the SD outputs This module can also be used to distribute SD SDI signals...

Page 2: ...ported HD SDI to SMPTE292M SD SDI to SMPTE259M C A distribution amplifier for HD SDI signals with SD SDI monitoring capability A distribution amplifier for SD SDI signals with 7 x SD SDI outputs Audio...

Page 3: ...ions Input Output 1125 1080 29 97i or sF 525 483 29 97i 1125 1080 25i or sF 625 576 25i 750 720 59 94P 525 483 29 97i 750 720 50P 625 576 25i 625 576 25i 625 576 25i 525 483 29 97i 525 483 29 97i Roll...

Page 4: ...e that for SD serial inputs these connectors will provide four SD distribution serial digital outputs SD Serial Out These are the three downconverted HD serial digital outputs of the unit via 75 Ohm B...

Page 5: ...ent CPU OK Green This LED will flash to indicate that the CPU is running Error Red This will only become illuminated when CRC EDH errors are being detected on the input or with no input present Warnin...

Page 6: ...Unit Status line 625 25i The standard of the SD monitoring output will be forced to 625 25i See the Valid Conversions table 525 29i The standard of the SD monitoring output will be forced to 525 29i...

Page 7: ...eezed horizontally Center Cut out To maintain the correct shape of objects on the 16 9 input this setting retains all vertical detail but crops the left and right edges of the image Letterbox Top To m...

Page 8: ...gnal when the ON item has been checked Audio Output Group 1 One group of audio can be carried through from the HD input to the SD outputs This item allows one of the input groups to be selected CRC ED...

Page 9: ...gs in the selected memory location Memory 1 to 8 and 9 16 This item will recall the settings from the selected memory location Memory 1 to 8 and 9 16 The memory location name may be renamed To change...

Page 10: ...item Any of the items may be selected from the list ROLLCALL LOG FIELDS Log Field Log Value Description INPUT LOST No input present OK Input present is OK STD string Input standard description CONVER...

Page 11: ...The destination for the information is set by the network code address as follows Address ID This item allows the address of the destination unit to be set To change the address type the new destinati...

Page 12: ...g A string value is always being sent Number A number value is always being sent No The message is not being sent Yes The message is being sent Internal Type Error Inconsistent behavior please contact...

Page 13: ...arameters of the unit software versions build level etc for identification purposes Firmware This shows the version of the firmware system Protocol This shows the protocol identification number This w...

Page 14: ...the status of the unit on four lines of text Line 1 This will show the status of the input signal It may show INP Input Loss Loss of input signal INP 1125 1080 29i The Input standard Line 2 This will...

Page 15: ...e remote control panel can be found in the Modular System Operator s Manual Information Window The Information window has four lines of text indicating the current state of the unit For details of the...

Page 16: ...RC EDH Total CRC EDH Reset Chroma_B W Output Standard Auto 625 25i 525 29i CRC EDH Total Errors xxxxxxx OK CRC EDH Total Errors CRC EDH Errors xxxxxxx OK CRC EDH Errors I P O P Output Standard Output...

Page 17: ...O P RollCall Memories Setup I P O P This item allows the input and output settings to be selected I P O P Output Standard Output Format Patterns CRC EDH On I P Loss Audio Grp1 Output Standard This all...

Page 18: ...16 9 to 4 3 conversions will appear squeezed horizontally Center Cut out To maintain the correct shape of objects on the 16 9 input this setting retains all vertical detail but crops the left and rig...

Page 19: ...K CRC EDH Errors This will display the current CRC EDH Error Rate CRC EDH Total CRC EDH Total Errors xxxxxxx OK CRC EDH Total Errors This will display the total CRC EDH Error Count since the last rese...

Page 20: ...emory 16 Memory 1 to 16 Memory 1 to 16 Save 1 16 Name 1 16 Recall 1 16 When a memory location has been selected this item allows it to be saved recalled or renamed Save 1 16 When selected the current...

Page 21: ...Log CONVERT Log CRC_ERR Log CRC_ERR_TOTAL INPUT STD CONVERT CRC ERR CRC ERR TOTAL SN Selecting the other not highlighted items will show their status ROLLCALL LOG FIELDS Log Field Log Value Descripti...

Page 22: ...t Input Loss Options are Unused Off Preset Video Delay SD O P Video Delay Input Present Input signal is present Input Loss Input signal is lost The destination for the information is set by the networ...

Page 23: ...tly Setting to 00 allows any type of unit to respond to the command For a list of unit IDs please contact your local Snell Wilcox agent Status This item displays the status of the RollTrack system Rol...

Page 24: ...IQMDA00OPS 090305 www snellwilcox com Version 1 Issue 2 N1 24 Manual Revision Record Date Version No Issue No Change Comments 270804 1 1 First issue released 090305 1 2 Audio Video delay match added...

Reviews: