IQOTR31
www.snellgroup.com
Controlling the IQOTR31 from the RollCall Control Panel
Issue 1 Rev 1
Page 20
©
2012 Snell Limited
6.5 RollTrack
The
RollTrack
screen allows information to be sent, via the RollCall™ network, to other
compatible units connected on the same network.
Use the settings on the
RollTrack
screen to:
•
Enable or disable the RollTrack functions.
•
Configure up to 16 RollTrack outputs.
•
Specify the conditions that trigger RollTrack data transmission.
•
Set RollTrack destinations.
•
Specify the RollTrack commands to be sent.
6.5.1 Disable All
When checked, all RollTrack items are disabled.
6.5.2 Index
This slider enables up to 70 RollTrack outputs to be setup. Dragging the slider selects the
RollTrack Index number, displayed below the slider. Clicking the
P
button selects the default
value.
6.5.3 Source
This slider enables the source of information that triggers the transmission of data to be
selected. Dragging the slider selects the RollTrack source, displayed below the slider. Clicking
the
P
button selects the preset value. When no source is selected,
Unused
is displayed.
6.5.4 Address
This item enables the address of the selected destination unit to be set.
The address may be changed by typing the new destination in the text area and then selecting
the
S
button to save the selection. Clicking the
P
button returns to the default preset
destination.
The RollTrack address consists of four sets of numbers, for example,
0000:10:01*99
.
•
The first set (
0000
) is the network segment code number.