Platform Box Switches and Alarms
Check all of the platform moving, drive, and
steering functions from the platform control box to
see that they cause the ATB 42/50 to move the
way it should.
For correct operating procedures see the
“Operation” chapter 8.
Pay particular attention to the Emergency Stop
switch to see that it turns the ATB 42/50 engine
off when struck.
Pay particular attention to the platform foot switch
to see that it deactivates the platform moving
switches when the foot switch is not stepped on.
■
Operator Horn
Press the operator horn (if the ATB 42/50 has
that option) to see that it works.
■
Motion Warning Alarm
Listen for the motion warning alarm (if the ATB
42/50 has that option) as you drive forward and
backward. Listen for the start up alarm when the
Anti-Restart Switch is first turned ON.
■
Ground Fault Circuit Interrupt
Connect the power input connector (at the rear of
the turntable) to a source of 125 volt AC, 15 A
electrical power.
If the ATB is equipped with the optional AC
generator, connect the power input connector
to the AC generator, start the engine, then set
the AC Generator switch to ON.
1. Push the TEST button (1) IN on the GFCI.
The RESET button (2) should pop OUT.
2. Press the RESET button (2) back IN. Set the
AC Generator switch to OFF if you used the
optional AC generator.
ATB 42/50 – 0161987
page 7 - 11
7. Daily Inspection and Maintenance