■
Starting From Platform Control Box
Before you begin to operate the ATB 42/50 from
the platform control box, a qualified operator must
perform the “Daily Inspection and Maintenance”
as described in chapter 7.
To start the engine from the platform control box
do the following:
1. Set the Battery switch (1) in turntable to ON.
2. Set the Emergency Stop switch (2) at the
ground controls to ON (pulled out).
3. Set the Platform/Ground Selector switch (3)
to PLATFORM (up).
4. Insert the key (4) and set the Master Key
Switch (5) to ON.
5. For LPG fuel operation: Completely open the
valve (6) on top of the LPG tank, (turn
counterclockwise until it stops).
6. Enter the platform, close the gate (7), and
attach the lanyard of your fall restraint to one
of the anchor points (8).
page 8 - 4
ATB 42/50 – 0161987
8. Operation