9. Emergency Operation
■
Emergency Operation Procedures
The following procedures are emergency
procedures only. DO NOT use them for normal
operation. Their purpose is to get the platform
and operator safely to ground when a problem
keeps the platform from lowering in a normal way.
❑
Operation From Platform Control Box
Switch settings listed in the first four steps below
must exist at the ground before emergency
operation procedures will work at the platform
control box:
1. The Battery switch (1) must be ON.
2. The Master Key Switch (2) must be ON.
3. The Emergency Stop switch (3) must be
pulled out (ON).
4. The Platform/Ground Selector switch (4)
must be set to PLATFORM (up).
5. Set the Emergency Stop switch (5) to ON
(pulled up).
6. Set the Anti-Restart switch (6) to ON.
7. Set the Boom Speed knob (7) to the speed
you want.
8. Hold the appropriate platform moving switch (8)
the direction you want the platform to move.
9. Step on the platform foot switch (9).
10. Hold the Emergency Power switch (10)
down and the platform will move.
ATB 42/50 – 0161987
page 9 - 1