Problem
Cause
Remedy
Engine will not start from
the platform control box.
(Continued):
Switches are set wrong.
(Engine will not crank).
Set Battery switch to ON.
At the ground control box:
Set the Master Key Switch to ON.
Pull Emergency Stop switch (out) ON.
Set Platform/Ground Selector switch to
PLATFORM.
At the platform control box:
Set the Anti-Restart switch to OFF.
Pull Emergency Stop switch (out) ON.
Turn the Anti-Restart switch to ON.
Turn the Anti-Restart switch to START.
The main circuit breaker,
in the platform control box
and/or the main system
circuit breaker, in the
ground control box has
tripped. (Engine will not
crank).
Wait three minutes, then try to start the
engine. If the engine will not start, refer the
problem to a qualified service technician.
Out of fuel. (Gasoline or
diesel engine cranks but
will not start).
Add fuel to tank, then alternately crank
engine for 20 seconds and let starter
motor cool for 60 seconds (20 on / 60 off).
LPG (Option)
Dual Fuel switch on the
platform control box is set
wrong. (Engine cranks but
will not start).
Set Dual Fuel switch at platform control
box to GAS or LPG.
Check the fuel gauge, on top of the tank,
to see if there is fuel in tank.
For LPG operation: Check to see that fuel
valve, on top of LPG tank, is open.
Alternately crank engine for 20 seconds,
then let starter motor cool for 60 seconds.
page 12 - 2
ATB 42/50 – 0161987
Chapter 12. Troubleshooting