Lit. No. 76454/76455/76456, Rev. 03
15
February 15, 2020
OPERATING THE SPREADER
SPREADING TIPS
• Spread ice melters with the storm to prevent
unmanageable levels of ice.
• Never exceed 10 mph (16 km/h) when spreading.
• For a wider pass, increase spinner speed.
• For a heavier pass, drive slower or increase
auger speed.
• Never operate spreader near pedestrians.
• Calculate spread pattern when near vegetation.
ACCESSORIES
The following accessories are available from your
distributor.
Optimum Flow Kit
The optimum flow kit improves material flow and
allows spreading of a 50/50 salt/sand mix with a
vibrator and dual pitch baffle.
Auger Tube Restrictor Kit
The auger tube restrictor kit prevents leaking issues
when handling fine pellet and flake materials.
AUTO‑REVERSE "Ar" FEATURE
1. If your control displays the "OL" code, this could
indicate a jammed auger.
2. Switch OFF the main power for 3 seconds.
3. Switch the main power ON. When the machine
starts to back up the "Ar" sequence will
automatically start and the auger will reverse for
several rotations to clear the jam.
4. After a pause of several moments, the auger will
automatically return to correct rotation.
5. If the jam is still not cleared, the control will again
display the "OL" code.
6. You may repeat Steps 2 and 3 for a second and
third time.
7. If, after the third attempt, the control displays the
"OL" code, you
must
extract the material that is
causing the problem.
8. Follow all safety instructions when clearing jams.