25
765042231 Rev.000
ALARMS AND FAULT ANALYSIS
If the fault is not corrected by following the above instructions ask for skilled assistance and avoid carrying out
any other operations, especially on the electricals. When informing the servicing company of the fault, state
1
and
5
numbers.
SIGNALS
LED
MEANING
Positive quick cooling led
if it is lit
, positive blast chilling in progress
if it flashes
, you have selected a positive blast chilling and preservation cycle
Negaitive quick cooling led
if it is lit
, negative blast chilling in progress
if it flashes
, you have selected a negative blast chilling and preservation cycle
HARD
Hard quick cooling led
if it is lit
, hard chilling in progress
if it flashes
, you have selected a hard chilling and preservation cycle
Blast chilling with probe LED
if it is lit
:
• blast chilling with probe in progress
if it flashes
:
•
the test to verify the insertion of the probe was not completed successfully
• you have selected a blast chill and preservation cycle with probe
Time-controlled blast chill LED
if it is lit
:
• timed blast chilling in progress
if it flashes:
• day and time setting in progress
• you have selected a timed blast chill and preservation cycle
Storing LED
if it is lit
, preservation in progress
if it flashes, the compartment probe is displayed during the cycle
N
P
1
2
6
3
4
5
7
R
E
F
A
B
C
D
A
B
C
D