background image

10

Summary of Contents for SUNJOE SJPPFP-CVR

Page 1: ...DO NOT touch any electrical switch 3 Shut off the gas 4 Extinguish any open flames 5 If odor continues leave area immediately 6 Call your local fire department mWARNING 1 This item is for outdoor use only and should NEVER be used in a building garage or any other enclosed area 2 DO NOT use this fire pit for indoor heating TOXIC carbon monoxide fumes can accumulate and cause asphyxiation or death 3...

Page 2: ...eaning procedures have been successfully executed 33 Do not use the appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been submerged 34 Death serious injury or damage to property may occur if any of the above precautions are not followed exactly mWARNING The...

Page 3: ... Battery compartment 4 Control knob 5 Housing 6 Adjustable feet 4 7 Handle Vent 8 Cylinder clamp screw 9 Door panel 10 Gas regulator 11 Gas regulator handle 12 Lava rocks Technical Data Diameter 23 in 58 cm Fuel Propane Fuel Tank 20 lbs 9 kg LP Cylinder Input 50 000 BTU h 14 65 kW Max Burn Time Up to 8 hours Min Gas Supply 25 PSI 175 kPa Max Gas Supply 250 PSI 1750 kPa Regulator Gas Pressure 11 in...

Page 4: ...parts from the packaging and check for missing parts 1 Place the fire pit on the ground and adjust the feet as needed Fig 1 2 Unscrew the battery compartment cap on the control panel install one AAA battery NOT included with the positive end facing out Fig 2 3 Place the lava rocks Max 24 25 lbs onto the burner of the gas fire pit Fig 3 Installation Location NOTE Your fire pit must be installed on ...

Page 5: ...place them with those specified by the manufacturer 2 Place the gas cylinder into the clamp in the base of the fire pit with the regulator facing OUTWARDS Turn the tightening screw clockwise to secure it in place Fig 6 Leakage Check 1 Mix a solution of 1 part liquid soap and 3 parts water 2 Turn the propane cylinder valve until fully open 3 Spoon or squirt several drops of the solution on to the g...

Page 6: ...ediately 5 Call your local fire department Lighting 1 Make sure the control knob is in the OFF position 2 Turn propane cylinder valve until fully open 3 Press down on the control knob and turn it counter clockwise to the IGNITE LOW position to light the burner Fig 8 Fig 8 4 If the burner is lit keep pressing down on the control knob for 10 seconds before releasing it mDANGER If at any time you are...

Page 7: ...if it will be subjected to freezing temperatures NOTE In a high salt environment such as by the sea corrosion occurs more rapidly than normal Frequently check for corroded areas and repair them promptly 1 Turn the control knob to OFF position 2 Turn to close the propane cylinder valve 3 Allow at least 45 minutes for the fire pit to cool down after use 4 Take out the battery from the battery compar...

Page 8: ...e Please call the Snow Joe Sun Joe customer service center at 1 866 SNOWJOE 1 866 766 9563 Gas odor Delayed ignition Incorrect burner flame Check all gas connections Check gas supply pressure Clean burner parts see manual CARE AND MAINTENANCE section Change battery Check gas supply pressure Clean burner parts Problem Remedy ...

Page 9: ...registration card available online from our website or calling our Customer Service Department at 1 866 SNOWJOE 1 866 766 9563 or by e mailing us at help snowjoe com Failure to register your Product will not diminish your warranty rights However registering your Product will allow Snow Joe to better serve you with any of your customer service needs WHO CAN SEEK LIMITED WARRANTY COVERAGE This Warra...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...sunjoe com ...

Reviews: