background image

2. Installation of eletric lock and exit push button :

P.S : (1)fail-secure type lock : Connect to 6-pin connector, blue
    

      and green point.

         (2)fail-safe type lock : Connect to 6-pin connector, purple
             and green point. 

         (3)exit push button can only use by dry- contact

A. Electr ic lock (fail secur e type) and r eader  .

AP-10

DC 12V

AP-10

DC 12V

ELECTRIC LOCK 

EXIT PUSH 

BUTTON

ADAPTER

ADAPTER

YELLOW

PURPLE

BLUE

GREEN

BROWN

RED

6 pin

A      EL     PT

A. Electr ic lock (fail secur e type) and r eader  .

AP-10

DC 12V

AP-10

DC 12V

ELECTRIC LOCK 

EXIT PUSH 

BUTTON

ADAPTER

ADAPTER

YELLOW

PURPLE

BLUE

GREEN

BROWN

RED

6 pin

A      EL     PT

AP-10

DC 12V

B. Electr ic lock(fail safe type) and the r eader .

AP-10

DC 12V

ELECTRIC LOCK 

EXIT PUSH 

BUTTON

ADAPTER

ADAPTER

YELLOW

PURPLE

BLUE

GREEN

BROWN

RED

6 pin

AP-10

DC 12V

B. Electr ic lock(fail safe type) and the r eader .

AP-10

DC 12V

ELECTRIC LOCK 

EXIT PUSH 

BUTTON

ADAPTER

ADAPTER

YELLOW

PURPLE

BLUE

GREEN

BROWN

RED

6 pin

Summary of Contents for ST-660

Page 1: ...ST 660 PROXIMITY ACCESS CONTROL SYSTEM OPERATION AND INSTALLATION MANUAL SOCA TECHNOLOGY CO LTD 2000 July 1 3 2 4 6 8 0 _ 9 7 5 X ...

Page 2: ...n Add series cards 8 7 Anti damage output setting 9 8 Changing system password command 9 9 Deletion to the 8 sets of the door opening passwords 10 10 Deletion of entire batch registration Delete all cards 10 11 Door opening using system password 11 12 Inquiry on registered card quantity 11 13 Inquiry on proximity reader program version 11 V INSTALLATION OF PROXIMITY READER 12 1 Connections 12 2 In...

Page 3: ...r to conduct functional selections of system setting modes System code is being set at 5678 on production In order to enter into the system to set up mode press first then press password and press again after completion The system setting mode is now being entered such as pressing 5 6 7 8 5 All proximity card or proximity key tag before being use in this reader must go through the activities of re...

Page 4: ...ard card dimension Read range 25 cm Can be printed directly from card printer SC 20 Thick card thickness 1 8 mm ISO standard card dimension Read range 20 cm Can be printed directly from card printer SC 30 Key tag readrange 12cm dimension 5 5L X 7 5H X 3 2W mm Ultrasonic connection water proof shock proof 1 3 2 4 6 8 0 _ 9 7 5 X 12345678 P 2 Power light RED Deny light YELLOW Oaky light GREEN Status...

Page 5: ... RED indicator brightens up Then observe for a beep sound and the screen will show ST 660 2 If not cut the power supply immediately If yes enter the system password 5678 then observe a beep sound and that the yellow indicator flashes If so then it is in the setting mode If there isn t any activation within 20 seconds this system will automatically escape out from the setting mode Completion of set...

Page 6: ...the proximity Reader will automatically terminate the system setting mode function 1 Add one card To register user s card and utilize proximity to register In the above operation if is being activated the card rgistration activities will be terminated S Y S T E M F U N C T I O N S E L E C T I O N P 4 PRESS 1 1 BEEP SOUND CARD PROXIMITY ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM...

Page 7: ...d But if there is any key in being done earlier then this operation will be the deletion to it P 5 DELETE ONE CARD ACCESS DENIED DELETE ONE CARD ˍˍˍˍˍˍˍˍˍ PRESS 2 1 BEEP SOUND ENTER THE LOST CARD 8 DIGITS NUMBER ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS SELECTION WILL BE SHOWN ON SCREEN WILL BE SHOWN ON SCREEN 3 BEEP SOUND DELETION SUCCESSFUL DELETION UNSUCCESSFUL RE...

Page 8: ...MINATE WILL BE SHOWN ON SCREEN ENTER SET OF CODE 1 8 1 BEEP SOUND SUCCESSFUL ENTER NEW 4 DIGITS CODE PRESS PRESS 3 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS SELECTION WILL BE SHOWN ON SCREEN SET SHUNT TIME 01 99 XX PRESS 4 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS SELECTION WILL BE SHOWN ON SCREEN WILL BE SHOWN ON SCREEN PRESS TERMINATE...

Page 9: ... There are a total of 8 sets of door opening passwords mode number is 1 2 Card proximity door opening that is door will open when the card is sensed mode number is 2 3 Card proximity plus press 4 digits password door opening mode number is 3 4 Proximity card or press 4 digits password door opening mode number is 4 P 7 IDENTIFICATION MODES 1 4 X PRESS 5 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A ...

Page 10: ...lso apply to single card entry P 8 ADD SERIES CARDS ˍˍˍˍˍˍˍˍ ˍˍˍˍ PRESS 6 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS SELECTION WILL BE SHOWN ON SCREEN WILL BE SHOWN ON SCREEN PRESS TERMINATE ENTER BEGIN 8 DIGITS CODE 1 BEEP SOUND 00 PRESS SINGLE CARD ENTERING ENTER QUANTITY OF CARDS 4 DIGITS BATCH 1 BEEP SOUND 3 BEEP SOUND HAS CARD NO BEEN REPEATED 1 BEEP SOUND SUCCES...

Page 11: ...this reader s password from production is being set at 5678 Please note that this password is necessary to enter into the system setting mode P 9 ALARM STATUS 0 ON 1 OFF X WILL BE SHOWN ON SCREEN PRESS TERMINATE TERMINATE ENTER ANTI DAMAGE MODE 0 ON OR 1 OFF PRESS 7 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS SELECTION WILL BE SHOWN ON SCREEN PRESS CHANGE COMMAND PASSW...

Page 12: ...l registered card and cannot be recovered P 10 CLEAR PASSWORDS WILL BE SHOWN ON SCREEN TERMINATE PRESS 3 PRESS 9 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS SELECTION WILL BE SHOWN ON SCREEN DELETE ALL CARDS WILL BE SHOWN ON SCREEN STATUS LIGHT RAPID FLASHES TERMINATE PRESS 9 PRESS 9 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS SELECTION WIL...

Page 13: ...EEP SOUND SYSTEM FUNCTIONS SELECTION WILL BE SHOWN ON SCREEN USER CARD COUNT XXXX WILL BE SHOWN ON SCREEN PRESS ANY KEY TO ESCAPE TERMINATE PRESS 1 PRESS 0 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS SELECTION WILL BE SHOWN ON SCREEN VERSION XXXX PRESS ANY KEY TO ESCAPE TERMINATE PRESS 2 PRESS 0 ENTER SYSTEM PASSWORD STATUS LIGHT ON WITH A BEEP SOUND SYSTEM FUNCTIONS S...

Page 14: ...or point 1 Anti Duress alarm output Orange Red Brown Black Purple BLUE Green Yellow Yellow Purple Blue Green Brown Red Door control relay Dry contact N O Door control relay Dry contact COM Anti Tamper switch normally open contact 8 PIN CONNECTOR 6 PIN CONNECTOR Exit push button Door control relay Dry contact N C GND DC 12V Anti Damage alarm output Anti Tamper switch normally close contact Anti Tam...

Page 15: ...ADAPTER ADAPTER YELLOW PURPLE BLUE GREEN BROWN RED 6 pin A EL PT A Electric lock fail secure type and reader AP 10 DC 12V AP 10 DC 12V ELECTRIC LOCK EXIT PUSH BUTTON ADAPTER ADAPTER YELLOW PURPLE BLUE GREEN BROWN RED 6 pin A EL PT AP 10 DC 12V B Electric lock fail safe type and the reader AP 10 DC 12V ELECTRIC LOCK EXIT PUSH BUTTON ADAPTER ADAPTER YELLOW PURPLE BLUE GREEN BROWN RED 6 pin AP 10 DC ...

Page 16: ...EXTERNAL RELAY N C COM AP 10 DC 12V SIREN 8Pin 6Pin Purple Blue Green Yellow Orange Brown Black Red Yellow Purple Blue Green Brown Red B Installation of reed switch normal open external relay anti duress REED N O COM N C N O N O COM AP 10 DC 12V 6Pin 8Pin SIREN DC12V EXTERNAL RELAY Purple Blue Green Yellow Orange Brown Black Red Yellow Purple Blue Green Brown Red B Installation of reed switch norm...

Page 17: ... the wires must be arranged correctly then take the enclosed key wrench and screws to mount it up 5 Power supply DC 12V 800mA 6 Power consumption standby 100mA active 160mA 7 Dimension 160mm L X 100mm W X 30mm H In order to avoid electric lock and proximity main equipment to operate together please do not share the power supply of the electric lock and proximity main equipment VI PRECAUTIONS 1 Bef...

Page 18: ... affect press key data Please confirm that the power supply wire and the control wire has been arranged to the space at the back of the display screen this is the wire arrangement area of this equipment in order to avoid the wires pressing on the PC board causing bad contact short circuit and interference 3 How to use the duress code setting Remedy 1 change the door opening mode to press 4 digits ...

Page 19: ...r sensor detection reed switch Remedy If the door sensor detection function is being set at ON for detail refer to item 7 of the setting mode functional selection in the manual and if the door is not closed within 30 seconds then the anti damage output function will be executed APPENDIX A P 17 ...