10
7
Message Format, GID = 0x60
Serial Interface, GID = 0x63
Control Group Commands
Use control commands to allow the host to control the EA15. All GID and
FID values are in hexadecimal.
Configuration, GID = 0x40
Status Group Commands
Use the status commands when you want the host to know the value of
certain status parameters in the EA15. All GID and FID values are in
hexadecimal.
Hardware, GID = 0x30
Configuration, GID = 0x40
Function
FID
Default Parameter
symbology identifier
40
disabled
Function
FID
Default Parameter
baud rate
40
19200
RTS / CTS hardware protocol
41
disabled
flow control
80
1000 ms
data bits
42
8
parity
43
none
stop bits
44
1
Function
FID
Default Parameter
disable all symbologies
03
no default
user reset factory defaults
04
no default
Function
FID
Value
version
C0
no default
decode version
C2
no default
sub-system version
C4
no default
Function
FID
Default Parameter
configuration signature
C0
no default