10
EN
3. %&'(
3.1. Quick Start ATy )*+,
542 955 B - 06/14 - EN
QUICK START
EN
ATyS
g
M
Automatic
Transfer Switching Equipment
Printing informations:
1 color Black. White paper 90g/m
2
.
Printing size: 420x297. Final size 210x297. This page visible first.
A separate sheet for each language.
Non contractual document.
Subject to change without notice.
Preliminary operations
Check the following upon delivery and after removal of the
packaging:
■
Packaging and contents are in good condition.
■
The product reference corresponds to the order.
■
Contents should include:
Qty 1 x ATyS M
Qty 1 x Emergency handle extension ROD
Qty 1 x Set of terminals
Quick Start instruction sheet
Warning
Risk of electrocution, burns or injury to persons and /
or damage to equipment.
This Quick Start is intended for personnel trained in the
installation and commissioning of this product. For further
details refer to the product instruction manual available on
the SOCOMEC website.
■
This product must always be installed and commissioned
by qualified and approved personnel.
■
Maintenance and servicing operations should be
performed by trained and authorised personnel.
■
Do not handle any control or power cables connected to
the product when voltage may be, or may become present
on the product, directly through the mains or indirectly
through external circuits.
■
Always use an appropriate voltage detection device to
confirm the absence of voltage.
■
Ensure that no metal objects are allowed to fall in the
cabinet (risk of electrical arcing).
Failure to observe good enginering practises as well as to
follow these safety instructions may expose the user and
others to serious injury or death.
Risk of damaging the device
■
In case the product is dropped or damaged in any way it
is recommended to replace the complete product.
Accessories
■
Bridging bars and 125A or 160A.
■
Control voltage transformer (400Vac -> 230Vac).
■
Voltage sensine and power supply TAP.
■
Terminal shrouds.
■
Additionnal aux contact block.
■
Polycarbonate enclosure.
■
Polycarbonate extension box.
■
Power Connection Terminals.
■
Sealable cover.
STEP 1
Cabinet / Back
Plate Installation
STEP 3
CONTROL /
AUX POWER
terminal
connections
STEP 2
Connecting the
POWER section
STEP 4
CHECK
STEP 5
Programming
Installation and Commissioning
STEP 6A
Automatic Operation
STEP 6C
Padlocking
STEP 6B
Emergency Manual
Operation
STEP 3
CONTROL / AUX POWER Terminals and wiring
www.socomec.com
www.socomec.com/en/atys-g-m
To download, brochures, catalogues and technical manuals.
Type
Terminal no.
Application
Status of the
contact
Description
Output
characteristics
Recommended
connection
cross-section
Inputs
I1: 207 / 208
Network/Network
With priority
Dry potential free
contact
0.5 to 2.5 mm²
(rigid)
0.5 to 1.5 mm²
(stranded)
Without priority
Network-Genset.
Automatic retransfer
Manual Retransfer
I1: 207 / 209
Network/Network
Source priority 1
Dry potential free
contact
Source priority 2
Network-Genset.
Stop the test on load
Test on load
I3: 207 / 210
Network-Network or
Network-Generating
set
AUTO mode
Dry potential free
contact
Automatic mode inhibition
Outputs
O1: 63 / 64
Network-Network or
Network-Generating
set
Product not available :
- Manual mode
- Command default
- Electronic default
- No source
Resistive load
2A 30 Vdc
0.5A 230Vac
Pmax : 60W or 125VA
Umax : 30Vdc or
230Vac
Product available
O2: 73 / 74
Network-Genset.
No start command genset
Resistive load
2A 30 Vdc
0.5A 230Vac
Pmax : 60W or 125VA
Umax : 30Vdc or
230Vac
Generating set starting