NeTYS 400-1000 VA  Product Manual 

SAFETY STANDARDS

 

 

CERTIFICATE AND CONDITIONS OF WARRANTY 

 

This SOCOMEC SICON UPS uninterruptible power system is guaranteed against manufacturing 
and material defects, for a period of 24 months 

from the date of purchase and not however more 

than 27 months from the date of shipment by SOCOMEC SICON UPS..  
 
The warranty is of the 'carry-in' type: free supply of parts and labour for repairs, with return of a product 
to be replaced to SOCOMEC SICON UPS, or authorized centres, at the customer’s cost and risk.

 

 

In order to use the warranty service, the user must respect the following rules: 

• 

the product must be returned exclusively in its original packaging. Any damage caused during 
shipping in packaging other than the original is not covered by the warranty; 

 

• 

the product must be accompanied by proof of purchase: a document (bill, invoice, receipt) showing 
the date of purchase and the information necessary to identify the product (model, serial number). 
The number of the authorization for return for repairs must also be attached, with a detailed 
description of the defect found in the product. If any of these elements is missing, the warranty is 
invalid. The return authorization number is issued by the service centres by telephone on receiving 
notification of the malfunction;

 

 
The warranty is recognised within Italian territory. If the UPS is exported outside Italian territory, the 
warranty shall be limited to the cover of the parts used to repair the fault.

 

.  
 

The warranty shall not apply in the following cases:

 

• 

Failures due to fortuitous circumstances or force majeure (lightning, floods, etc.); 

• 

Failures due to negligence or improper use (use outside tolerance limits: temperature, 
humidity, ventilation, electric power supply, applied load, batteries); 

• 

Insufficient or inadequate maintenance; 

• 

Attempted maintenance, repairs or modifications not carried out by SOCOMEC SICON UPS 
personnel or personnel from a support centre authorised by SOCOMEC SICON UPS. 

• 

If the battery has not been recharged in accordance with the terms indicated on the packaging 
and in the manual, in cases of extended storage or UPS inactivity.

 

 

SOCOMEC SICON UPS may, at its own discretion, opt for the repair of the product or for the 
replacement of the faulty or defective parts with new parts or with used parts that are equivalent to 
new parts with regard to functions and performance. 
 
Defective or faulty parts replaced free of charge are to be put at the disposal of SOCOMEC SICON 
UPS that becomes the sole owner. 
 
Replacements or repairs of parts and any modifications to the product during the warranty period shall 
not extend the duration of the warranty. 
 
In no case will SOCOMEC SICON UPS be responsible for damages (including, without limitations, 
damage for loss of earnings, interruption of activity, loss of information or other economic losses) 
deriving from the use of the product. 
 
The present conditions are subject to Italian law. Any dispute falls under the province of the Court of 
Vicenza.

 

 

 

* For further information: 

www.socomec-sicon.com

 

SECTION 1  

!

 

3

Summary of Contents for NeTYS PE 1000 VA

Page 1: ... MANUALE DI PRODOTTO PRODUKT HANDBUCH MANUAL DE PRODUCTO UNINTERRUPTIBLE POWER SUPPLY UPS ALIMENTATION SANS INTERRUPTION ASI SISTEMA DI CONTINUITÀ UPS UNTERBRECHUNGSFREIE STROMVERSORGUNG USV SISTEMA DE ALIMENTACIÓN ININTERRUMPIDA SAI ...

Page 2: ...AL DESCRIPTION 5 2 1 LED BASED CONTROL AND DISPLAY PANEL 6 3 UNPACKING AND INSTALLATION 7 3 1 UNPACKING 7 3 2 ENVIRONMENTAL REQUIREMENTS FOR INSTALLATION 7 3 3 CONNECTION TO THE MAINS POWER SUPPLY AND CONNECTING THE LOAD 7 4 OPERATING MODES 8 5 COMMUNICATION 9 6 MAINTENANCE 10 6 1 REMEDIES FOR MINOR PROBLEMS 10 7 TECHNICAL DATA 11 ...

Page 3: ...all be limited to the cover of the parts used to repair the fault The warranty shall not apply in the following cases Failures due to fortuitous circumstances or force majeure lightning floods etc Failures due to negligence or improper use use outside tolerance limits temperature humidity ventilation electric power supply applied load batteries Insufficient or inadequate maintenance Attempted main...

Page 4: ...sible 5 Protection ligne téléphonique modem I D 1 Ventilatore griglia di ventilazione 2 Connettore seriale RS232 USB 3 Presa di uscita UPS 4 Presa ingresso rete e fusibile 5 Protezione linea telefono modem 1 Lüfter Belüftungsanlage 2 Serieller Anschluß RS232 USB 3 Ausgang zur Last USV 4 Netzeingang und Sicherung 5 Sicherung Telefonleitung Modem E 1 Ventilador tomas de aire 2 Conector serie RS232 U...

Page 5: ... the mains power supply Do not dispose of batteries in a fire the battery may explode CAUTION a battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries remove watches rings or other metal objects and use tools with insulated handles The batteries constitute an internal power source for the UPS and mean that t...

Page 6: ...he constant monitoring of the power supply which duly filtered and stabilised on models with AVR and if considered suitable is used to supply consumers In cases of a mains failure or if the mains is considered to be outside limits accepted by the load the inverter the heart of the UPS is activated immediately Drawing on the power stored in the batteries the inverter generates a voltage that instan...

Page 7: ...mittent alarm every 2 seconds battery needs replacing Continuous alarm UPS failure MODEL 1000 PE ON OFF switch Turns the UPS ON and OFF Visual indication of operating mode LED lit NORMAL MODE mains ok LED flashing BATTERY MODE mains absent or abnormal In BATTERY MODE Battery LED bar capacity 25 steps In NORMAL MODE Load LED bar power 25 steps UPS failure LED red Acoustic alarm Intermittent alarm e...

Page 8: ...he manufacturer supplied or recommended cables and accessories for connections to the RS232 USB serial interface It is recommended that the batteries be left to charge for 8 hours the first time the unit is used 3 3 CONNECTION TO THE MAINS POWER SUPPLY AND CONNECTING THE LOAD Cables with the appropriate cross section and conforming to the safety standards in force should be used for connection to ...

Page 9: ...MODE LED on the front panel flashes In cases of prolonged mains failure the UPS powers the consumers until it shuts down when the batteries are fully depleted see the chapter on COMMUNICATION for orderly shutdown via software Just before shutdown when the battery charge runs out fully low battery charge is signalled via a rapid intermittent acoustic alarm The UPS automatically returns to normal op...

Page 10: ... to close the programs and shutdown the system When mains power returns the system will restart automatically All NeTYS models are equipped with RS232 and USB communication interface not available on the NeTYS PE 400 model COMMUNICATION SOLUTIONS Uni Vision local management software for local shutdown of Windows Linux systems Free on http www socomec fr page_uk lien_prod_ups htm RS232 USB INTERFAC...

Page 11: ...bottom of the UPS PROBLEM CAUSE SOLUTION The UPS works in battery mode even if mains power is available Poor connection to the input mains The mains voltage is out of range Input protection triggered blown fuse or automatic switch Check the connection of the cable to the UPS and to the mains outlet No solution because mode of operation is correct Replace the input fuse with another of the same typ...

Page 12: ... Stepwave Transfer time 2 6 milliseconds typical Protection Overload deep discharge and short circuit Load connection socket IEC320 3 C13 4 C13 BATTERY Typical back up time PC 15 LCD monitor 8 min 15 min 20 min 45 min Battery recharge Under permanent charge even when the UPS is off mains present REPORTING AND COMMUNICATION Communication interface RS232 USB Local communication software UPS Manageme...

Page 13: ...cestershire GL7 1YG Tel 44 1285 644 444 Fax 44 1285 644 414 ups uk sales socomec com I N A S I A INDIA Atma Ram Mansion 1 21 Asaf Ali Road IN New Dehli 110 002 Tel 91 11 23234411 Fax 91 1123232639 hpl hplindia com SINGAPORE 25 Tagore Lane 01 02 Singapore Godown SG 787 602 Singapore Tel 65 6 554 0900 Fax 65 6 458 7377 general socomecsicon com sg THAILAND 17 178 Prachachuen Road Tungsonghong Laksi T...

Reviews: