3. INSTALLATION
3.5. Wall-mounting
This inverter is designed for mounting on masonry walls. If the walls are made using different materials, the installer must use suitable
mounting supports. The mounting bracket dimensions are indicated in the figure below. Fix the bracket (supplied) securely to the
wall before hanging the inverter on it.
WARNING!
Mount it vertically or at a maximum angle of 45° (see figure 3.5-2). Be careful, as in this case a drop in performance
(derating) may occur due to the deterioration of heat dispersal.
259
425
6
569
324
3.5-1
Securing the mounting bracket with screws
3.5-2
Correct and incorrect installation examples
X
MAX. 45°