background image

 

 

 

188 

 

Relief factor when totaling 
(cannot be enabled for picking)  
You can specify in setup mode that the scale must be relieved by a certain number of number 
increments between placing individual items 
If the scale is not relieved, the weight value is not saved to the totaling memory, and the error 
message "Error 55 - Place Weight" is issued. This for instance prevents saving an item twice.  
 
Auto totaling 
The Auto Totaling function can be enabled in setup mode. 
In this case, only the first item must be saved with the Plus key, all other items are automatically 
saved to the totaling memory after the scale is loaded and settles. 
The Plus key remains hidden as long as auto totaling is enabled. 
If auto totaling is terminated with cancel, error message or change of measurement location, 
auto totaling must be restarted with the Plus key. 
Info: Just like manual totaling, auto totaling can be defined as a condition that triggers a printout 
(see Section 8 Printing). 
 
Assigning and deleting the sequential number 
Every entry (plus, manual, cancel) into the totaling memory is assigned a 4-digit sequential number.  
The sequential number is not reset in the factory default condition. 
Resetting the sequential number can be optionally programmed in setup mode: 

 

disabled (no reset = factory default) 

 

on Delete Total key  

 

on switch off 

 

function key "Delete Seq. Number" 

 
Item counter 
The item counter only counts actually totaled transactions. The item counter is incremented by 1 
for each new transaction with plus, manual, or automatic totaling. The item counter counts to 999; 
this is followed by an error message. The item counter is decremented by 1 for a cancellation. 
The item counter is automatically reset to zero when the total is deleted.  
 
Keys that trigger printouts 
The Plus, Cancel, and Total keys can trigger a receipt printout. 
A prerequisite for this is that the relevant key has a print format assigned. 
The option "Display, print and delete" must be selected for the Total key in setup mode Total key 
function. 

Summary of Contents for 3035

Page 1: ...Manual Terminal 3035 ...

Page 2: ... efficient and cost effective as possible Prior to use please read this user manual with care Inappropriate use may cause harm to you or the terminal If you have questions or experience problems with your terminal that are not addressed in the user manual please contact your Soehnle Industrial Solutions service location or the customer service department of Soehnle Industrial Solutions Telephone 4...

Page 3: ... mode 19 4 2 Program settings 21 4 3 Setup mode settings terminal 22 4 4 Setup mode settings terminal 27 4 5 Setup mode settings communication 30 4 6 Setup mode settings Service 37 4 7 Reset Terminal 37 5 Basic functions 38 5 1 Switch on 38 5 2 Switch off 38 5 3 Program selection 38 5 4 Zero set 38 5 5 Tare function 39 5 6 Gross display 39 5 7 Scale switching 39 5 8 Ten X display x10 40 5 9 Hold f...

Page 4: ...ng 72 6 6 8 Auto totaling picking 72 6 6 9 Preferred totaling scale 72 6 6 10 Assigning and deleting the sequential number 73 6 6 11 Item counter 73 6 6 12 Keys that trigger printouts 73 6 6 13 Display current totals 73 6 6 14 Display individual items 74 6 5 15 Display options with the Info key 75 6 6 16 Save the current values to fixed memory 75 6 6 17 Organization data Identifier 76 6 6 18 Setti...

Page 5: ...entifier 131 6 10 9 Settings in setup mode 132 6 11 Neutral measurements 134 6 11 1 Function keys 134 6 11 2 Display view 135 6 11 3 Display information field 136 6 11 4 Tare function 137 6 11 5 Neutral measurement functions 137 6 11 6 Totaling picking 139 6 11 7 Quantity control 143 6 11 8 Neutral measurement with several weighing bridges 145 6 11 9 Display options with the Info key 145 6 11 10 S...

Page 6: ... alibi memory 197 7 2 Interface 1 RS 232 internal 198 7 3 Port 2 199 7 4 Port 3 200 7 5 USB 201 7 5 1 Data logger 202 7 6 Ethernet 203 7 7 Print format 204 7 8 IT settings 205 7 9 Anybus 207 7 10 Barcode 208 7 10 1 Decimal delimiter numeric 208 7 10 2 Display scanned values in the display field 209 7 10 3 Barcode selection filter 210 7 10 4 Barcode printing and output 213 7 11 IO Control 214 7 11 ...

Page 7: ...7 ...

Page 8: ...he intended uses and maintenance of the terminal The manufacturer is not liable if the following instructions are not observed When using electrical components under elevated safety requirements the corresponding regulations must be adhered to Never perform service work on the terminal while the unit is under power The product warranty is null and void if the terminal is installed inappropriately ...

Page 9: ...entitled at its discretion to either remedy the defect or to supply a replacement Replaced parts become the property of Soehnle Industrial Solutions The statutory regulations apply if the defect remedy or replacement delivery fail The product warranty period begins on the date of purchase Please retain the invoice as proof For service contact your dealer or the Soehnle Industrial Solutions custome...

Page 10: ...ent instrument whose performance can be influenced by unfavorable environmental conditions The unit should be acclimated at ambient temperature for 2 hours after unpacking or transport The rated ambient temperature is 10 to 40 C The setup location is a key factor for the function of your scale Select an appropriate setup location to protect the terminal against impact vibration excessive heat or c...

Page 11: ...n entries and for software updates Interfaces 1 x RS 232 or USB in the basic version Internally with R232 USB and Ethernet 2 additional interface slots RS232 Anybus slot for bus interfaces such as Profibus ProfiNet Option I O card for 6 outputs and 4 inputs user defined Operating temperature 10 C to 40 C 1 measurement location in the basic version 2 additional internally connectable measurement lo...

Page 12: ... After the weighed goods are placed the scale needs time to settle The unit of measure sign kg g remains hidden until the scale has settled When the scale has settled and the value has stabilized this is indicated by displaying the unit of measure sign LOG Alibi memory use 100 Alibi memory use 80 Alibi memory empty Keyboard locked Data logger Multi range 1 Multi range 2 Multi range 3 Resolution X1...

Page 13: ... calibrated scales must be recalibrated in regular intervals For this purpose contact a Soehnle Industrial Solutions service location or your assigned official calibration agency Never damage the official seals since this voids the calibration 2 4 1 Type tag The terminal has an electronic type tag It is displayed by pressing the Info key 2 4 2 Calibration counter The calibration counter displays h...

Page 14: ...h the zero set key for calibrateable The current weight reading is then displayed with the previously stored zero point Once the cause for the under or overload is removed the scale returns to zero and is operational without reboot Backlighting and color Can be adjusted in setup mode terminal display Procedure for power failure The scale goes back to the previously left status when power returns S...

Page 15: ...tare Revision Scale parameters Alibi memory only for Total Picking Display Assignment table measurement locations Interface 1 RS232 internal Service Counting Keyboard Adjustment reference points Interface Port 2 Qualified staff Checking Date time internal measurement location Interface Port 3 Classifying Organization data USB Recipes Error memory Ethernet Neutral measurements User password Print f...

Page 16: ...gned levels the Function Page key is used to page trough the levels Navigating with the function keys Moves the cursor up in the list Moves the cursor down in the list End Closes setup mode Next Starts the highlighted menu selection Back Returns to next higher level Cancel Returns without making a change Delete Deletes an item with return Save Saves and entry or change Cursor to the right Cursor t...

Page 17: ...mized under Terminal Display If desired can be switched on and switched with the F3 Secondary Display key Symbol bar Shows information about the status of the currently enabled measurement location Information field Depending on the situation or on a customizable basis shows organization data totals for addition special control characters classes when classifying operator guide switching point Dis...

Page 18: ...etup mode Setup mode Program settings Terminal Scale Communication Service Weighing tare Revision Scale parameters Alibi memory only for Total Picking Display Assignment table measurement locations Interface 1 RS232 internal Qualified Service Counting Keyboard Adjustment reference points Interface Port 2 staff Checking Date time internal measurement location Interface Port 3 Classifying Organizati...

Page 19: ... selection menu Setup Mode Navigating setup mode The function keys F1 to F6 are available to control the functions They perform various functions depending on the program and the situation The relevant function is shown in the display in the function bar Meaning of the function keys Moves the cursor up in the list Moves the cursor down in the list End Closes setup mode Next Starts the highlighted ...

Page 20: ...tings For editable values numeric or alphanumeric values can be entered with the keypad Service area The service area is protected by a password The parameters in this area can only be maintained by trained service staff Please contact your Soehnle Industrial Solutions service location ...

Page 21: ...s and Parameters see Section 6 6 17 3 Counting Settings and parameters see Section 6 7 14 4 Controlling Settings and parameters see Section 6 8 10 5 Classifying Settings and parameters see Section 6 9 10 6 Recipes Settings and parameters see Section 6 10 9 7 Neutral measurements Settings and parameters see Section 6 11 12 8 Vehicle scale Settings and Parameters see Section 6 12 10 9 Dynamic switch...

Page 22: ...revisions Latin 1 Unicode UTF8 Output parameters uni Output of all programmable terminal parameters incl the currently enabled measurement location via the interface by using the IT 2 unidirectional interface 2 Display Backlighting Entry Adjustment for lighting intensity enter in percent via the number keypad 30 is darker 100 is full lighting intensity Factory default 80 Backlighting color Choices...

Page 23: ...none Factory default none 3 Keyboard Keyboard lock Single several or all keypad keys can be locked By pressing the key to be locked the status of the key is switched from open to locked and vice versa Save and close by pressing the Enter key for 3 seconds Button beep Select off or on Keyboard confirmation beep Factory default off Confirmation beep Select off or on Confirmation beep e g error messa...

Page 24: ...F6 cancel without saving the entry with F5 Back Parameter tare value is highlighted retrieve with F6 Edit enter with alpha numeric keypad Save entry with F6 cancel without saving the entry with F5 Back Deleting an existing fixed value Page with Arrow key F3 and F4 Delete the highlighted fixed value with F2 Delete The resulting gap in the sequential numbering will be closed Enter new fixed value Pr...

Page 25: ...ric Password with up to 8 characters with keypad After enabling access to setup mode and program selection is only possible by entering the correct password If the password is lost the entry CLEAR grants access Delete Deletes the password and reestablishes unrestricted access 8 Login function Enabling Select on or off Factory default off Password query Select on or off Factory default off Enter ed...

Page 26: ...inal Reset terminal Select execute or do not execute Execute deletes all custom settings of the terminal and resets the factory defaults This does not reset scale parameters fixed value parameters and the print format ...

Page 27: ...hoices Service setting filters can be directly edited in the service area Livestock scale Calm Normal Restless Factory default Service setting Select function is only possible by unlocking the user filter setting in the service area Hold mode Choices Inactive No hold function Rest key Hold when settled outside of the zero setting range cancel with On key Rest empty Hold when settled outside of the...

Page 28: ...nabled as secondary display function in the display above F3 Secondary Display key in scale mode The selection does not also display the programmed unit of measure as the first unit Empty message Enter The range of the percentage of the weighing range at which the empty message is output Enter with number keypad in percent Info the display does not show the empty message Factory default 1 00 Contr...

Page 29: ...s measurement value from the zero point Reference point 1 weight Reading Query of the weight reading from reference point 1 Reference point 1 gross reading Query of the adjusted gross reading from reference point 1 Reference point 2 weight reading Query of the weight reading from reference point 2 Reference point 2 gross reading Query of the adjusted gross reading from reference point 2 Reference ...

Page 30: ...d function Find Several entries by entering the oldest and youngest sequential number Use of supplemental field Select none Barcode Org data A Org data B Org data C Org data D Date time 2 Interface 1 RS232 internal see interface description 470 508 090 for more details Use of interface Select none 2795 14 2795 12 2795 20 IT IT 2 uni directional Barcode Second large display Digital scale When alrea...

Page 31: ...ctory defaults 3 Interface Port 2 see interface description 470 508 090 for more details Use of interface Select none 2795 14 2795 12 2795 20 IT IT 2 uni directional Barcode Second large display Digital scale When already assigned to another interface port this selection is shown as locked Factory default none Baud rate Select 1200 2400 4800 9600 19200 38400 Factory default 9600 Data bits Select 7...

Page 32: ...20 IT IT 2 uni directional Barcode Second large display Digital scale When already assigned to another interface port this selection is shown as locked Factory default none Baud rate Select 1200 2400 4800 9600 19200 38400 Factory default 9600 Data bits Select 7 8 Factory default 8 Parity Select none even odd Factory default none Xon Xoff Select off or on Factory default off Factory default Select ...

Page 33: ...th USB interface or on Reset Terminal 6 Ethernet see interface description 470 508 090 for more details Use of Ethernet Select none IT When already assigned to another interface port this selection is shown as locked Factory default none IP Address Enter IP Address Factory default 010 010 005 005 Subnet Mask Enter Subnet Mask Factory default 255 255 255 000 Gateway Enter Standard Gateway Factory d...

Page 34: ...zero is entered Starting with number 1 the value is incremented by one after each output with the Print key Delete value after printout Enter Operated as per interface description 470 508 090 Factory default Select Do not execute Customized settings in print format setting remain intact Execute Resets print format setting to factory defaults 8 IT settings see interface description 470 508 090 for ...

Page 35: ...data record no sending of data record A send data record 1 x immediately B send data record 1 x weight change settle C send data record change settle D send data record change settle empty E send data record change settle empty empty F send data record continuously G send data record 3005 continuously H send data record 1 x on settle Factory default none Time pattern data packets Enter Time spacin...

Page 36: ...e details Decimal delimiter Num Select off or on Factory setting on Display timer barcode Enter Display time barcode numeric with character keypad Factory default 2500 ms Select filter No Enter Filter No numeric with character keypad Factory default 1 Control code Filter No 01 Enter Code control code numeric with character keypad Factory default 0 First position filter No 01 Enter Start of filter ...

Page 37: ...isabled Inputs Selection for assigning the individual inputs Input E1 Input E2 Input E3 Input E4 Factory default all disabled 4 6 Setup mode settings Service The service area is protected by a password The parameters in this area can only be maintained by trained service staff 4 7 Reset Terminal In order to reset all terminal settings except scale parameters and service area back to factory defaul...

Page 38: ...F4 Down Arrow key Starting the selected program Press F6 to enter See Section 6 for information about all application programs 5 4 Zero set Zero set corrects small variances from the zero point e g due to dirt buildup on the scale Press the Zero Set key The symbol bar displays the following character for zero display Zero set range calibratable and not calibratable 1 to 3 of the weighing range If ...

Page 39: ...igital scale can also be connected with the RS 232 interface as measurement location No 30 Switching between connected measurement locations is accomplished manually or automatically Manual switching Briefly press the key The connected measurement locations are sequentially queried Press and hold the key A data entry field opens and the measurement location No can be entered and saved directly Aut...

Page 40: ...s Not calibratable scale If the scale is programmed as not calibratable the 10x higher resolution is permanently displayed Pressing the key switches on the 10x higher resolution Pressing the key again switches the 10x higher resolution back off X10 is shown in the symbol bar as long as the 10x higher resolution is switched on The function is disabled when the unit is switched off In setup mode the...

Page 41: ...with Switch On key Max empty Hold at maximum reached weight with settle outside of empty message higher weight sets new hold canceled by removing load from scale Slave key Hold at every increase in weight without settle outside of empty message higher weight sets new old canceled with Switch On key Slave empty Hold at every increase in weight without settle outside of empty message higher weight s...

Page 42: ...Secondary display settings The function of the secondary display is switched on by first using the Function Page key to page to the Setting Functions level Gross x 10 Secondary display Prog ram Setup mode F 1 F 2 F 3 F 4 F 5 F 6 Press the F6 Setup Mode key Press the F3 and F4 Arrow keys to move in the list to the Terminal item and then select the latter by pressing the F6 Next key Now use the Arro...

Page 43: ...rammed in the sub menu Secondary Display Second unit of measure Tare value x10 resolution Gross Net Current weight Reference quantity Reference weight Target value Difference to target value Specific weight Vehicle plate number Weight of first single weighing Indicator light display Note the function setting must match the application program The factory default setting of the secondary display is...

Page 44: ... Gram Kilogram g kg 1 g 1 000 g Tons t 1 000 000 g Pound lb 453 59237 g Milligram mg 0 001 g Ounce oz 28 349523125 g The second unit of measure is selected by using the Function Page key to page to the Setting Functions level Gross x 10 Secondary display Prog ram Setup mode F 1 F 2 F 3 F 4 F 5 F 6 Press the F6 Setup Mode key Press the F3 and F4 Arrow keys to move in the list to the Scale item and ...

Page 45: ...tem and then select the latter by pressing the F6 Next key You can move around in the list with the F3 and F4 Arrow keys The second unit of measure is specified with F6 Enter After the second unit of measure was selected pressing the F1 End key returns the unit to scale mode ...

Page 46: ...r keypad Four keys to are available to retrieve the organization data memories Enter name Start by entering the name max 12 characters for the required organization data memories in setup mode Start setup mode with F6 key in the Setup Functions key level Highlight Terminal with F4 Arrow key F6 Next Highlight Organization Data with F4 Arrow key F6 Next A ORG to D ORG can now be retrieved and the na...

Page 47: ...for the organization data memory A Now enter parts to be recorded such as screws nuts washers pins etc in Fixed Values Organization Data A Operator was already entered as the name for the organization data memory B Now enter various operators such as Smith Jones Anderson Johnson etc in Fixed Values Organization Data B The fixed values can now be easily enabled from the database at any time Retriev...

Page 48: ...ry with F6 cancel without saving the entry with F5 Cancel Closing the database The list is closed with the F5 Back key Database maintenance with optional Soehnle Professional application software 3035 The PC application software 3035 addresses the need for single or multiple applications to maintain the names and contents of the organization database The application software is connected via the R...

Page 49: ... Mode Display Decimal Delimiter Only the specified number of characters can be entered into the data entry field entries beyond this are not displayed and are not saved Alpha numeric fields The numbers 0 to 9 can be entered directly with the number keypad Entries are aligned left The numbered keys have multi function assignments that include capital letters and special characters The special chara...

Page 50: ...switched off Remove key lock Start Terminal Keypad Keypad Lock in Setup Mode The display shows a schematic representation of the keypad Locked keys are shown in the display with a cross By pressing the key the status of the key is switched from locked to open and vice versa The change is entered and enabled by pressing the Enter key for 3 seconds When no more keys are locked the key lock symbol in...

Page 51: ...tart by pressing the Enter key for 3 seconds Login request or close by pressing the C key for 3 seconds Details for the dialog and the IT data communication commands are included in the interface description 470 508 090 Enabling and settings In setup mode Terminal Login Function various versions from a simple process start request to a password query with monitoring by an external IT system can be...

Page 52: ...YES keys and an IT data record with the log in rejection is transmitted after which the terminal is in weighing mode Enabling password query external IT query Start setup mode with F6 key in the Setup Functions key level Highlight Terminal with F4 Arrow key F6 Next Highlight Login Function with F4 Arrow key F6 Next Highlight Password Query with the F4 arrow key press F6 to proceed to the password ...

Page 53: ... with the command code is transmitted to the IT function for checking and approval and the display shows the hourglass The IT function must approve the password within 5 seconds If the password is not approved in this time the security query Cancel Login is displayed Or the password query is redisplayed if an incorrect password is confirmed display message Error 02 Incorrect Password If the passwo...

Page 54: ...t Enter desired password with a maximum of 35 characters and save with F6 Notes Entering the internal password is not followed by an external IT password query When the internal terminal password is entered the password is always queried when the Login function area is started If the password is lost the Login function area can be accessed by entering CLEAR without a password The login query windo...

Page 55: ...with F4 Arrow key F6 Next Highlight Login Function with F4 Arrow key F6 Next Password query enter internal terminal password and press F6 Save key If the password is lost the Login function area can be accessed by entering CLEAR without a password Highlight Delete Password with F4 Arrow key F6 Next The internal password is deleted Enter login text The text for the login query window can be customi...

Page 56: ... Weighing and tare Total picking Counting Checking Classifying Recipes Neutral measurements Vehicle scale Dynamic switching Percentage weighing 6 1 Selecting application programs Switch on the terminal After the boot cycle the terminal automatically starts the last enabled application program In order to start setup mode use the Function Page key to switch to the setup functions level 6 2 Function...

Page 57: ...e key is used to page trough the levels Meaning of the function keys Moves the cursor up in the list Moves the cursor down in the list End Closes setup mode Next Starts the marked menu selection Back Returns to next higher level Cancel Returns without making a change Delete Deletes an item with return Save Saves an entry or change Cursor to the right Cursor to the left 6 4 Custom programs In addit...

Page 58: ...are Select the options in setup mode menu Scale 6 5 1 Function keys The function keys F1 to F6 are available to control the functions These are assigned in 2 levels switching between the levels is accomplished with the Function Page key 1 Tare functions level Tare Fix Add Tare Int Tare Multi Tare Save Fix F 1 F 2 F 3 F 4 F 5 F 6 2 Setup functions level Gross x10 Secondary display Prog ram Setup mo...

Page 59: ...tion field is controlled in Setup Mode Program Settings Weighing Tare Display Information Field The following options are available Factory default Switching between the individually used functions e g switching functions Output and Inputs and Organization Data Memory IO control Continuous display of output and input states Organization data database Continuous display of the organization data mem...

Page 60: ...he display of the tare memory without change If you wish to change the value of the tare memory a new value can be entered with the number keypad which is then stored in tare memory with F6 as a manual tare entry 6 5 6 Tare with manual tare entry Setting the tare for a known container weight e g with filled container on the scale Enter the known tare weight with the number keypad and save the valu...

Page 61: ...mory a new value can be entered with the number keypad which is then stored in tare memory with F6 as a manual tare entry 6 5 8 Cumulative tare Determining the tare of several even different containers with known tare weight Press the F2 Cumulative Tare key in the Tare function level Enter the known tare weight of the first container with the number keypad Confirm with the F6 Save key Repeat the p...

Page 62: ...cation in setup mode under Scale Scale Parameters Auto Tare with On setting Place an empty container on the empty scale At settle the first weight value is stored in tare memory and deducted from the weight display The weight is displayed with the Net indicator The message Auto Tare Enabled is displayed during automatic tare When the load is removed from the scale the tare memory is automatically ...

Page 63: ...e desired memory location enter the desired fixed value with F6 Edit Direct retrieval with memory location number or part number Use the number keypad to enter the part or memory location number The specification whether the part or memory location number is retrieved is made in setup mode The part number is entered as a left aligned search criterion the memory location number is entered as a righ...

Page 64: ...xed Tare key in the Tare function level The display now shows the last retrieved fixed tare value Select from the list Page with the Arrow keys Retrieve the desired fixed value with F6 Save Direct retrieval with memory location number Use the number keypad to enter the memory location number Direct retrieval with barcode or IT information in Section 7 10 Barcode Management or contact your Soehnle ...

Page 65: ...g the key 6 5 14 Save the current values to fixed memory In order to directly save fixed tare values into fixed memory start by saving the tare value or by entering tare manually Pressing the F5 Enter Fix key directly saves the value to fixed memory The data entry window for fixed tare values is displayed The fixed tare value name is entered by pressing the F6 Edit key Enter the name with the keyp...

Page 66: ...with F6 Parameter name is highlighted retrieve with F6 Edit enter with keypad Save entry with F6 cancel without saving the entry with F5 Cancel Other parameters are edited in the same manner Deleting an existing fixed value Page with F3 and F4 Arrow keys Delete the highlighted fixed value with F2 Delete The resulting gap in the sequential numbering will be closed Save new fixed value Press F1 New ...

Page 67: ...xecute deletes all ORG D fixed values Display information field Select what data is displayed in the information field Factory default Switching between the individually used functions e g switching functions Output and Inputs and Organization Data Memory IO control Continuous display of output and input states Organization data database Continuous display of the organization data memories Fixed t...

Page 68: ...ng bridges For purposes of the description the following only addresses totaling Totaling memory with several connected scales A central totaling memory is maintained for all connected scales Totaling memory capacity Up to 999 transaction can be stored in totaling memory The totaling memory needs to be deleted thereafter 6 6 1 Function keys The function keys F1 to F6 are available to control the f...

Page 69: ...lay setting is set to the factory default Tip You can use the F3 key to start an additional secondary display e g to additionally display the 10x higher resolution or the tare weight The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with x10 display ...

Page 70: ...d Inputs Total continuous display of totaling memory Last item Continuous display of the last item IO control Continuous display of output and input states Organization data database Continuous display of the organization data memories Fixed tare values Continuous display of the enabled fixed tare value memory Display barcode Continuous display of the scanned barcode Example information field disp...

Page 71: ...y added to the unit total Cancel F4 The F4 Cancel key is used to cancel or reverse weigh individual items Pressing the Cancel key is followed by the prompt to either place the weight to be canceled on the scale or to enter the sequential number of the weight to be canceled Information about the sequential number can be retrieved with the key combination and F5 Plus Use the number keypad to enter t...

Page 72: ...ce Weight is displayed This for instance prevents saving an item twice 6 6 8 Auto totaling picking The Auto Totaling function can be enabled in setup mode In this case only the first item must be saved with the Plus key all other items are automatically saved to the totaling memory after the scale is relieved for totaling only and placing weight and settle If auto totaling is terminated by cancel ...

Page 73: ... Error 45 The item counter is decremented by 1 for a cancellation The item counter is automatically reset to zero every time the total is deleted 6 6 12 Keys that trigger printouts Additional keys or functions such as plus manual cancel or total can be used as keys that trigger a printout for the totaling picking functions e g to print a receipt A prerequisite for this is that the relevant key has...

Page 74: ... the totaling memory by sequentially pressing the key and F5 Plus key The item list begins with the latest entry Page through the list with the F3 older entries and F4 newer entries Arrow keys The last 50 entries can be retrieved Press the F5 Back key to close the display of the individual items and to return to the previous screen Info Display information field with item list Last Item can be pro...

Page 75: ...totaling memory F5 Plus Displays all items stored in the totaling memory item list The individual items can be retrieved with the Arrow keys F3 F4 Tare key Displays the current tare weight in tare memory Press the key after pressing the key 6 6 16 Save the current values to fixed memory In order to directly save fixed tare values into fixed memory start by saving the tare value or by entering tare...

Page 76: ...etup Mode key in the settings function level and from there press F6 Save to start Program Settings F6 Next retrieves the program settings for the highlighted application program 2 Totaling picking Totaling or picking Select totaling or picking for the following settings Totaling means that the individual items are removed from the scale after they have been saved to totaling memory Picking means ...

Page 77: ...g transaction can then be started Factory default Display Print Delete Relief factor Enter in d with number keypad The number of number increments by which the scale must be relieved during the totaling transaction therefore allowing the next weight to the saved to totaling memory If the scale is not relieved the weight value is not saved to the totaling memory and the error message Error 55 Place...

Page 78: ... F6 are available to control the functions These are assigned in 4 levels switching between the levels is accomplished with the Function Page key 1 Counting function level Ref 10 Ref Variab Ref Weight Total Cancel Add F 1 F 2 F 3 F 4 F 5 F 6 2 Control functions level Ref Stat Ref Fix Units Contr F 1 F 2 F 3 F 4 F 5 F 6 3 Tare functions level Tare Fix Add Tare Int Tare Multi Tare Save Fix F 1 F 2 F...

Page 79: ...ondary display e g to additionally display the reference weight the net weight or the tare weight The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with reference weight ...

Page 80: ...emory Last item Continuous display of the last item Organization data database Continuous display of the organization data memories Fixed reference weight values Continuous display of the enabled reference weight memory Display barcode Continuous display of the scanned barcode Example information field display setting to fixed reference weight values Example the control display shows a indicator l...

Page 81: ...is entered Press the F3 Ref Weight key and use the number keypad to enter the known reference weight An already existing reference weight is displayed and can be overwritten The entry is made with the default unit of measure grams If you wish to enter the reference weight in Kilograms the unit of measure can be switched with the key Confirm your entry with the F6 Save key The terminal has saved th...

Page 82: ...lue with F2 Delete Respond YES to the security question The resulting gap in the sequential numbering will be closed Save new fixed value Press F1 New The memory location number is assigned by the equipment The first number in parenthesis indicates the free memory locations the second number indicates the assigned memory locations Parameter name is highlighted retrieve with F6 Edit enter with keyp...

Page 83: ...he Counting Functions level Totaling means that the individual items are weighed sequentially The weight is added to totaling memory and the load is removed from the scale after each individual weighing Picking means that the weighed items are left on the scale The weight is added to totaling memory and the scale returns to zero without the load being removed from the scale The measurement locatio...

Page 84: ... and unit counts can be totaled Cancel F5 The Cancel key is used to cancel or reverse weigh individual items Pressing the Cancel key is followed by the prompt to either place the weight to be canceled on the scale or to enter the sequential number of the weight to be canceled Press the key combination Info and F5 Plus for information about the sequential number Use the number keypad to enter the s...

Page 85: ...ments between placing individual items If the scale is not relieved the weight value is not saved to the totaling memory and the error message Error 55 Place Weight is issued This for instance prevents saving an item twice Auto totaling The Auto Totaling function can be enabled in setup mode In this case only the first item must be saved with the Plus key all other items are automatically saved to...

Page 86: ...t trigger printouts The Plus Cancel and Total keys can trigger a receipt printout A prerequisite for this is that the relevant key has a print format assigned The option Display print and delete must be selected for the Total key in setup mode Total key function Display current totals During a totaling transaction you can display the accumulated totals by sequentially pressing the key followed by ...

Page 87: ... unit count and the permitted tolerance are specified in Unit Control mode More information about this under Unit Control Totaling different counted parts Totaling different counted parts can be prevent if determining a new reference weight is only allowed after deleting the totaling memory by switching Delete Total to On in setup mode 6 7 7 Reference statistics Determining the weight tolerances o...

Page 88: ...number keypad to enter the desired unit count confirm with the F6 Save key Use the number keypad to enter the acceptable tolerance confirm with the F6 Save key If you wish to specify the plus and minus tolerances separately you will need to set Program Settings Counting Separate Tolerance to On in setup mode The display switches to the display view Counting the indicator light function with specia...

Page 89: ...nctions level Enable start mode in setup mode under Program Settings Counting Start Mode End unit control Press the key to start the 2nd level control functions and press the F5 Quantity Contr key then delete with the F2 Delete key or delete everything with the key 6 7 9 Counting with several weighing bridges If several scales are connected each scale can be used to determine the reference weight ...

Page 90: ...ent of the enabled scale the reference weight cannot be determined for these parts and Error 04 Reference Weight Tool Small is shown in the display These parts need to counted by a scale with a smaller number increment Example for a scale with 1 g number step Factory default is 10 d 10 g for the total reference weight of the reference parts By reducing the factory default to 5 d the scale accepts ...

Page 91: ... list The individual items can be retrieved with the Arrow keys F3 F4 Tare key Displays the current tare weight in tare memory Press the key after pressing the key 6 7 12 Save the current values to fixed memory In order to save reference values and target values for unit control directly to fixed memory start by determining the reference weight and then add the target value units with tolerances P...

Page 92: ... F6 Edit key Enter the name with the keypad and save the entry by pressing the F6 Save key The part number is entered in the same manner 6 7 13 Organization data Identifier Detailed information about organization data can be found in Section 5 11 on page 45 ...

Page 93: ...ale prompts for the missing parts until the minimum reference weight has been reached If the calculated reference weight is less than 10 of the smallest number increment of the scale the error message Error 04 Reference Weight Tool Small is issued Optimizing the reference weight Enter the percentage value The scale optimizes the reference value when more parts are placed The upper limit of the opt...

Page 94: ...ndividual items are removed from the scale after they have been saved to totaling memory Picking means that the individual items remain on the scale after they have been saved to totaling memory and that the next item is placed on the scale Factory default Totaling Auto totaling picking Select off or on On means that only the respectively first item must be saved with the Plus key all other items ...

Page 95: ...ew fixed value Press F1 New The memory location number is assigned by the equipment The first number in parenthesis indicates the free memory locations the second number indicates the memory locations with assigned fixed values Parameter name is highlighted retrieve with F6 Edit enter with keypad Save entry with F6 Save cancel without saving the entry with F5 Cancel Other parameters are edited in ...

Page 96: ...y of the indicator light function Total continuous display of totaling memory Last item Continuous display of the last item Organization data database Continuous display of the organization data memories Fixed reference weight values Continuous display of the enabled reference weight memory Display barcode Continuous display of the scanned barcode Factory default Factory default Factory default Se...

Page 97: ...ual weight and the control range with a control light The colors green yellow red incl the relevant range symbol visualize the variance from the specified target value Control ranges below tolerance within tolerance with exact target value reached above tolerance 6 8 1 Function keys The function keys F1 to F6 are available to control the functions These are assigned in three levels switching betwe...

Page 98: ...ay e g to additionally display the target value or the difference to the target value The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with difference to the target value ...

Page 99: ...ct target value reached 6 8 4 Tare function The description and detailed instructions for the tare function can be found in Section 6 5 page 57 6 8 5 Control functions Entering target values Press the F1 Target Value key in the Control Function level 1 You can now place a sample part to save the target value or enter the target value in the programmed unit of measure with the number keypad Confirm...

Page 100: ...et Value key followed by the key or directly with the key Control fixed values Contr Fix Up to 999 target values can be stored in a power failure proof memory Each memory location has the following entries a three digit sequential number a name alpha numeric max 18 characters a part number alpha numeric max 18 characters Target value Tolerance minus Tolerance plus a Retrieving the fixed control we...

Page 101: ... Back key b Retrieving the fixed control weight list for controlling Press the F2 Contr key in the Control Function level 1 Fix The display now shows the last retrieved fixed value Selecting from the list Page with the F3 or F4 Arrow keys until you have reached the desired memory location enter the desired fixed value with F6 Save Direct retrieval with part number or storage location number Use th...

Page 102: ... 6 Totaling picking This function is also available in controlling mode The function can be used to total pick control items The totaling functions are controlled with the function keys in the Control Functions level Totaling means that the individual items are weighed sequentially The weight is added to totaling memory and the load is removed from the scale after each individual weighing Picking ...

Page 103: ...Error 46 is displayed if the scale is not under load Cancellations or reverse weighings are marked in the printed receipt as Cancellation A cancellation causes the sequential number to be incremented by one while the item counter is decremented by one If the item counter is 0 no further cancellations are possible this is displayed by error message Error 48 Total F4 The F4 Total key finishes the to...

Page 104: ...quential number is not reset in the factory default condition Resetting the sequential number can be optionally programmed in setup mode disabled no reset factory default Deleting the totaling memory Switching the terminal off Function key F1 Delete Seq No when retrieved with the and F4 Total keys Item counter The item counter only counts actually totaled transactions The item counter is increment...

Page 105: ...e totaling memory by sequentially pressing the key and F5 Plus key The item list begins with the latest entry Page through the list with the F3 older entries and F4 newer entries Arrow keys The last 50 entries can be retrieved Press the F5 Back key to close the display of the individual items and to return to the previous screen Info Display information field with item list Last Item can be progra...

Page 106: ...splays the stored fixed values Controlling Contr Fix memory F3 Target Values Displays the enabled target value with tolerances F4 Total Displays the current totals in the totaling memory F5 Plus Displays all items stored in the totaling memory item list The individual items can be retrieved with the Arrow keys F3 F4 Tare key Displays the current tare weight in tare memory Press the key after press...

Page 107: ... settings function level and from there press F6 Save to start Program Settings F6 Next retrieves the program settings for the highlighted application program 4 Checking tolerance separate Select off or on Selecting On has the effect that and tolerances for the unit control function are specified and queried separately Selecting Off has the effect that the tolerance is queried only once and is the...

Page 108: ... Off Function key enables a different function key Factory default disabled Total key function Select what functions are assigned to the Total key Only display totals The total is displayed after the Total function key is pressed The user can then decide whether to delete the totaling memory Press the F2 Delete Total key to delete the totaling memory Then confirm the security question with YES usi...

Page 109: ...er indicates the memory locations with assigned fixed values Parameter name is highlighted retrieve with F6 Edit enter with keypad Save entry with F6 Save cancel without saving the entry with F5 Cancel Other parameters are edited in the same manner Closing the fixed value list The list is closed with the F5 Back key Retrieving fixed values Select whether fixed values are retrieved with sequential ...

Page 110: ...isplay of the indicator light function Total continuous display of totaling memory Last item Continuous display of the last item Organization data database Continuous display of the organization data memories Controlling fixed values Continuous display of the enabled target value memory Display barcode Continuous display of the scanned barcode Factory default Factory default Factory default Select...

Page 111: ...d Above upper limit highest class 6 9 1 Function keys The function keys F1 to F6 are available to control the functions These are assigned in three levels switching between the levels is accomplished with the Function Page key 1 Classification functions level Target values Class Fix Total Cancel Add F 1 F 2 F 3 F 4 F 5 F 6 2 Tare functions level Tare Fix Add Tare Int Tare Multi Tare Save Fix F 1 F...

Page 112: ...g to additionally display the10x higher resolution or the tare weight The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with x10 resolution Example weighed item in weight class 3 ...

Page 113: ...the last enabled values Page with the arrow marker in the list using the F3 and F4 Arrow keys Retrieve the selected class limit for editing with F6 Edit The lower limit of class 1 must be entered as a weight value the standard unit of measure is the programmed unit of measure Select whether the weight is entered in grams or kilograms with the key A prerequisite for the 2nd unit of measure is that ...

Page 114: ...weight display Press the key sequence F1 Target Value and F2 Delete or only the key Fixed classification values Class Fix Up to 999 target values can be stored in a power failure proof memory Each memory location has the following entries a three digit sequential number a name alpha numeric max 18 characters a part number alpha numeric max 18 characters Lower limit Class 1 Upper limit Class 1 Uppe...

Page 115: ...5 Back key b Retrieving the fixed control weight list for controlling Press the F2 Class Fix key in the Control Function level 1 The display now shows the last retrieved fixed value Selecting from the list Page with the F3 or F4 Arrow keys until you have reached the desired memory location enter the desired fixed value with F6 Save Direct retrieval with part number or storage location number Use t...

Page 116: ... 9 6 Totaling picking This function is also available in classification mode The function can be used to total pick items of the same class assignment The totaling functions are controlled with the function keys in the Classification Functions level Totaling means that the individual items are weighed sequentially The weight is added to totaling memory and the load is removed from the scale after ...

Page 117: ...Error 46 is displayed if the scale is not under load Cancellations or reverse weighings are marked in the printed receipt as Cancellation A cancellation causes the sequential number to be incremented by one while the item counter is decremented by one If the item counter is 0 no further cancellations are possible this is displayed by error message Error 48 Total F4 The F4 Total key finishes the to...

Page 118: ...e sequential number is not reset in the factory default condition Resetting the sequential number can be optionally programmed in setup mode disabled no reset factory default Deleting the totaling memory Switching the terminal off Function key F1 Delete Seq No when retrieved with the and F4 Total keys Item counter The item counter only counts actually totaled transactions The item counter is incre...

Page 119: ...e totaling memory by sequentially pressing the key and F5 Plus key The item list begins with the latest entry Page through the list with the F3 older entries and F4 newer entries Arrow keys The last 50 entries can be retrieved Press the F5 Back key to close the display of the individual items and to return to the previous screen Info Display information field with item list Last Item can be progra...

Page 120: ... fixed classification values Class Fix memory F3 Target values Displays the enabled class limits F4 Total Displays the current totals in the totaling memory F5 Plus Displays all items stored in the totaling memory item list The individual items can be retrieved with the Arrow keys F3 F4 Tare key Displays the current tare weight in tare memory Press the key after pressing the key 6 9 8 Save the cur...

Page 121: ...by pressing the F6 Setup Mode key in the settings function level and from there press F6 Save to start Program Settings F6 Next retrieves the program settings for the highlighted application program 5 Classifying Record outside of class Select within or outside This parameter specifies whether a data record is transmitted to the printer or IT only within the class or also outside of the class If a...

Page 122: ...e assigned to the Total key Only display totals The total is displayed after the Total function key is pressed The user can then decide whether to delete the totaling memory Press the F2 Delete Total key to delete the totaling memory Then confirm the security question with YES using the F1 to F3 keys this is followed by the total printout Display print and delete total After pressing the Total fun...

Page 123: ...he same manner Closing the fixed value list The list is closed with the F5 Back key Retrieving fixed values Select whether fixed values are retrieved with sequential memory location numbers or part numbers Factory default Part number Delete fixed classification values Select do not execute or execute Execute deletes all fixed classification values IO assignments Select do not execute or execute Ex...

Page 124: ...s The function keys F1 to F6 are available to control the functions These are assigned in three levels switching between the levels is accomplished with the Function Page key 1 Recipe functions level Comp Contr Total Cont ainer Manual Add F 1 F 2 F 3 F 4 F 5 F 6 2 Tare functions level Tare Fix Add Tare Int Tare Multi Tare F 1 F 2 F 3 F 4 F 5 F 6 3 Setup functions level Gross x10 Secondary display ...

Page 125: ...condary display e g to additionally display the 10x higher resolution or the tare weight The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with x10 resolution ...

Page 126: ...etting to control display 1 Below tolerance 2 Within tolerance 3 Above tolerance Exact target value reached 6 10 4 Tare function The description and detailed instructions for the tare function can be found in Section 6 5 page 57 6 10 5 Recipe functions Place the first container on the scale and then determine tare Place the first component of your recipe into the container Press the Function Page ...

Page 127: ...ption automatic container switch If the Automatic option is selected in setup mode under Program Settings Recipes Container Switch the container can be switched without pressing the F4 Container key Option auto tare By enabling the Auto Tare option in setup mode a new container placed on the scale is tared without pressing the key Total F3 Remove the last container from the scale after pressing th...

Page 128: ...ed by the F5 Plus key The type of addition component No tare value and net value are displayed for the current container The Arrow keys are used to individually retrieve all components Once the container was completed with the container key it can no longer be retrieved The component list display is closed with the F5 Back key Display container list While processing a recipe you can display a list...

Page 129: ...Use the number keypad to enter the desired target value confirm with the F6 Save key Use the number keypad to enter the acceptable tolerance in the weight unit of measure confirm with the F6 Save key Press the key to switch between weight unit of measure and percent If you wish to specify the plus and minus tolerances separately you will need to enable Separate Tolerance in Setup Mode Program Sett...

Page 130: ... Program Settings Recipes Totaling Outside of Tolerance must be switched to Within in setup mode Displaying target value and tolerance Press the key followed by the F2 Comp Contr key Or Press the Comp Contr key in the Recipe Function level 1 Next component with changed target weight tolerance Press the F1 Comp Contr key and use the number keypad to enter the new target values Switching point for c...

Page 131: ...ate is only lifted by pressing the F2 Start key in the Recipe Functions level Enable the start mode in setup mode under Program Settings Recipes Start Mode 6 10 7 Display options with the Info key Pressing the key gives you the following options F1 Fixed tare Displays the stored fixed tare values fixed tare memory F2 Comp Contr Displays the enabled target value with tolerances for the component co...

Page 132: ...ce or also outside of the tolerance If a data record is also accepted outside of the tolerance it is then marked with a special character Factory default outside Totaling outside of tolerance Select within or outside This parameter specifies whether totaling into totaling memory is only permitted for values within the tolerance or also for values outside of the tolerance Factory default outside To...

Page 133: ...data is displayed in the information field Factory default Switching between the individually used functions e g control indicator light recipe memory Organization Data Memory Control display Continuous display of the indicator light function Total continuous display of totaling memory Last components Continuous display of the last component Organization data database Continuous display of the org...

Page 134: ...e function keys F1 to F6 are available to control the functions These are assigned in four levels switching between the levels is accomplished with the Function Page key 1 Level Neutral measurement functions Spec Variab Spec Weight New UoM Fix Total Cancel Add F 1 F 2 F 3 F 4 F 5 F 6 2 Level Control functions Quantities Contr Start F 1 F 2 F 3 F 4 F 5 F 6 3 Level Tare functions Tare Fix Add Tare I...

Page 135: ...ry display e g to additionally display the specific weight the net weight or the tare weight The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with specific weight ...

Page 136: ...dicator light function Total continuous display of totaling memory Last item Continuous display of the last item Organization data database Continuous display of the organization data memories Fixed neutral measurement values continuously displays the enabled memory of the specific weight Display barcode Continuous display of the scanned barcode Example information field display setting to fixed n...

Page 137: ...e terminal determines the specific weight and then displays the number of placed quantity units Additionally placed material is displayed in real time Spec Weight Data entry of a known specific weight Press the F3 Spec Weight key and use the number keypad to enter the known specific weight An already existing specific weight is displayed and can be overwritten The entry is made with the default un...

Page 138: ... number is entered as a right aligned search criterion Enter the desired fixed value with F6 Edit Process an existing fixed value from the list Process the highlighted fixed value with F6 Edit Parameter name is highlighted retrieve with F6 Edit enter with keypad Save the entry with F6 cancel without saving the entry with F5 Cancel Other parameters are edited in the same manner Deleting an existing...

Page 139: ...d a fixed value memory is used that is not located in the fixed memory the error message Error 83 Fixed Value Not Found is displayed The unit returns to scale made and the selected function is canceled 6 11 6 Totaling picking This function is also available for the neutral measurement function The function can be used to total pick items of the same unit of measure The totaling functions are contr...

Page 140: ...ght The relief factor 0 only requires a change in weight Gross tare and net values and unit counts can be totaled Cancel F5 The Cancel key is used to cancel or reverse weigh individual items Pressing the Cancel key is followed by the prompt to either place the weight to be canceled on the scale or to enter the sequential number of the weight to be canceled Press the key combination Info and F5 Plu...

Page 141: ...etween placing individual items If the scale is not relieved the weight value is not saved to the totaling memory and the error message Error 55 Place Weight is issued This for instance prevents saving an item twice Auto totaling The Auto Totaling function can be enabled in setup mode In this case only the first item must be saved with the Plus key all other items are automatically saved to the to...

Page 142: ...gger printouts The Plus Cancel and Total keys can trigger a receipt printout A prerequisite for this is that the relevant key has a print format assigned The option Display print and delete must be selected for the Total key in setup mode Total key function Display current totals During a totaling transaction you can display the accumulated totals by sequentially pressing the key followed by the F...

Page 143: ... outside of tolerance must be disabled in setup mode The target unit count and the permitted tolerance are specified in Unit Control mode More information about this under Quantity Control Totaling different counted parts Totaling different counted parts can be prevented if determining a new specific weight is only allowed after deleting the totaling memory by switching Delete Total to On in setup...

Page 144: ...key in level 4 of the settings functions Displaying target value and tolerance Press the key followed by the F3 Quantity Contr key Switching points for quantity control The terminal must have an I O card installed if you wish to forward the control values with the interface e g to a control light or to a control The I O card must be enabled with execute in setup mode under Program Settings Neutral...

Page 145: ...c weight should be determined on the scale with the smallest number increments Select the scale with scale key After determining the specific weight the switch can be made to a higher capacity bulk scale This way larger quantities can be accurately measured with the reference weight determined on the reference scale 6 11 9 Display options with the Info key Pressing the key gives you the following ...

Page 146: ...ry The specific weight the target weight and the tolerance have already been saved The part name and the part number are then added The data entry window for the target value is displayed The neutral measurement memory name is entered by pressing the F6 Edit key Enter the name with the keypad and save the entry by pressing the F6 Save key The part number is entered in the same manner 6 11 11 Organ...

Page 147: ...ce or also outside of the tolerance If a data record is also accepted outside of the tolerance it is then marked with a special character Factory default outside Totaling outside of tolerance Select within or outside This parameter specifies whether totaling into totaling memory is only permitted for values within the tolerance or also for values outside of the tolerance Factory default outside De...

Page 148: ...mory and the error message Error 55 Place Weight is displayed Between 0 and 30 number increments can be specified On 0 totaling is possible as long as the scale has not settled once Factory default 15 number increments Fixed neutral measurement values Edit fixed neutral measurement values Selecting available fixed values from the list Page with F3 and F4 Arrow keys Retrieve the desired fixed value...

Page 149: ...ching point and thus without unintentionally starting a new transaction The frozen state is only lifted by pressing the F6 Start key in the Control Functions level Factory default off Display information field Select what data is displayed in the information field Factory default Switching between the individually used functions e g control indicator light totaling memory Organization Data Memory ...

Page 150: ... to the tare weight the difference corresponds to the net weight 6 12 1 Function keys The function keys F1 to F6 are available to control the functions These are assigned in three levels switching between the levels is accomplished with the Function Page key 1 Level Motor vehicle weighing functions First weighing Second weighing Single weighing F 1 F 2 F 3 F 4 F 5 F 6 2 Level Tare functions contro...

Page 151: ...itionally display the motor vehicle registration plate or the weight of the first single weighing The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with motor vehicle registration plate ...

Page 152: ...ght function Total continuous display of totaling memory Last item Continuous display of the last item Organization data database Continuous display of the organization data memories Display barcode Continuous display of the scanned barcode Example information field display setting to organization data database Example the control display shows a indicator light indicator in the information field ...

Page 153: ...g fee in the Weighing Fee Section If the foreign content query is enabled for the first weighing the data entry window for the portion to calculate the foreign content opens more information about the foreign content in the Foreign Content Section The user is now prompted to Drive the vehicle on the scale or enter the empty weight Allow the motor vehicle to drive onto the scale or enter a known em...

Page 154: ...ference corresponds to the load weight Identifying motor vehicles with barcodes or card readers simplifies your processes Related information is found under barcode management or you can contact your Soehnle Industrial Solutions service partner There is also the option to assign motor vehicles The automatic query of the registration plate or the third party material can be enabled in setup mode Si...

Page 155: ...ormat is assigned Select from existing print format with the quick change by pressing the key followed by the key Printed receipt See examples for printed receipts in Section 8 1 Standard print formats factory defaults First weighing print format No 21 Second weighing print format No 22 Single weighing print format No 23 The weight determined by the scale is printed in parenthesis on the printed r...

Page 156: ...ow for the fixed value OrgD memory max 999 entries with 6 lines each Weighing fee prompt When required a weighing fee can be printed on the weighing receipt For this purpose enablee the weighing fee prompt in setup mode The following prompt settings are available off The weighing fee function is disabled for every weighing transaction Single weighing The weighing fee function is only enabled for t...

Page 157: ...cide for each process whether to calculate the foreign content The user prompt opens the query window Foreign content query no foreign content is charged if 0 is entered as the value and confirmed with F6 Foreign content calculation The portion deducted from the net amount can be specified in percent or as a weight value The following settings for calculating the foreign content are available in s...

Page 158: ...t Individual vehicle entries can deleted with F2 Delete The entire fleet list is deleted by executing Delete Fleet List in setup mode The F5 Back key cancels the second weighing without deleting an entry from the fleet list 6 12 4 Totaling This function is available in adapted form for the vehicle scale It automatically totals all gross tare and net values determined by a first second or single we...

Page 159: ...ecial character target values The total display is then resumed with the next totaling transaction Tip In order to permanently display the total in the information field program the setting in Setup Mode Program Settings Vehicle Scale Information Field Display to Total Display current totals During a totaling transaction you can display the accumulated totals by sequentially pressing the key follo...

Page 160: ... the user can decide whether to delete the totaling memory Press the F2 Delete Total key to delete the totaling memory Press the F6 Back key to continue totaling without deleting the memory Display individual items During a totaling transaction you can retrieve the individual items from the totaling memory by sequentially pressing the key and F5 Plus key The item list begins with the latest entry ...

Page 161: ...er Setup Mode Communication IO Control IO operating Mode Switching outputs indicator light control Switching point Signal Indicator light Logic S1 inverted Vehicle weighing reset Outbound light enabled red not enabled off S2 disabled S3 Vehicle scale reset Outbound light enabled green not enabled off S4 disabled S5 Empty message Inbound light enabled green not enabled red S6 inverted Vehicle weigh...

Page 162: ...lerance green Exact target value reached green Above tolerance limit red You can also display the difference to the target weight in figures with or sign in the top left corner of the secondary display Enable the secondary display with the F3 Secondary Display key in level 3 of the settings functions You can also display the difference to the target weight in figures with or sign in the top left c...

Page 163: ... be used to manage customer or address data with the vehicle scale The application for an address field can consist of 35 characters with 6 lines Detailed information about organization data can be found in Section 5 11 on page 45 6 12 9 Settings in setup mode The parameters in setup mode allow you to customize the application program Neutral Measurements to your specific needs Start setup mode by...

Page 164: ...foreign content Choices Off no query foreign content Single weighing Single and first weighing Single and second weighing Factory default off Calculation Foreign content Choices Percent The entered percentage share is calculated as a value to deduct from the determined net value Weight value The entered weight value is calculated as a value to deduct from the determined net value Factory default P...

Page 165: ...nts are printed and deleted at the same time A new totaling transaction can then be started Factory default Display Print Delete Delete fleet list Select do not execute or execute Attention Execute deletes fleet list entries IO assignments Select do not execute or execute Execute enables the switching function for an external control light or control An I O card must be installed to control the sw...

Page 166: ...e the switching function 6 13 1 Function keys The function keys F1 to F6 are available to control the functions These are assigned in three levels switching between the levels is accomplished with the Function Page key 1 Level Dynamic switching functions Out puts In puts Start Total Cancel Add F 1 F 2 F 3 F 4 F 5 F 6 2 Level Tare functions fixed values Tare Fix Add Tare Int Tare Multi Tare Save Fi...

Page 167: ...he F3 key to start an additional secondary display e g to additionally display the tare value or the x10 display The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with tare value ...

Page 168: ...g memory Last item Continuous display of the last item Organization data database Continuous display of the organization data memories Fixed values dynamic switching continuously displays the enabled memory for dynamic switching Display barcode Continuous display of the scanned barcode Example information field display setting to fixed dynamic switching values 6 13 4 Tare function The description ...

Page 169: ...or relieving the scale or the specified condition is reached the output is enabled or disabled depending on the settings The settings for the switching points apply to all connected scales measurement locations e g they retain their validity or function when the measurement location is changed Additional conditions can be selected for the target values weight values for dynamic switching program s...

Page 170: ... The menu window displays the switching point with the new enabled condition Switching lag timer T polarity inverted I lockout V and net N is displayed the switching point of the weight value is also always displayed Repeat the procedure for all other switching points to be assigned Once you have all desired switching points assigned enable your entries with the F1 Enable key The F5 Cancel key clo...

Page 171: ...ernally The settings for the inputs apply to all connected scales measurement locations e g they retain their validity or function when the measurement location is changed Press the F2 Inputs key in the Dynamic Switching Function level A list of the 4 inputs E1 to E4 is generated with the current function settings You can move around in the list with the F3 and F4 Arrow keys F6 Edit retrieves the ...

Page 172: ...conditions can now be deleted with the F2 Delete key or the key The deletion is effective immediately and the scale goes back to weighing mode Fixed dynamic switching values Switching Fix Up to 999 specific weights can be stored in a power failure proof memory Each memory location has the following entries a three digit sequential number a name alpha numeric max 18 characters a part number alpha n...

Page 173: ...quential numbering will be closed Save new fixed value Press F1 New The memory location number is assigned by the terminal The first number in parenthesis indicates the free memory locations the second number indicates the assigned memory locations Parameter name is highlighted retrieve with F6 Edit enter with keypad Save the entry with F6 cancel without saving the entry with F5 Cancel Other param...

Page 174: ...oad is removed from the scale after each individual weighing Picking means that the weighed items are left on the scale The weight is added to totaling memory and the scale returns to zero without the load being removed from the scale The measurement location cannot be changed during the picking transaction The selection between totaling or picking is made in setup mode Program Settings The select...

Page 175: ...item counter is 0 no further cancellations are possible this is displayed by error message Error 48 Total F4 The F4 Total key finishes the totaling The display now shows the gross tare and net totals along with the item counter and the sequential number of the last transaction Available choices for displaying the total Deleting the totaling memory The following functions can be assigned to the Tot...

Page 176: ...e sequential number is not reset in the factory default condition Resetting the sequential number can be optionally programmed in setup mode disabled no reset factory default Deleting the totaling memory Switching the terminal off Function key F1 Delete Seq No when retrieved with the and F4 Total keys Item counter The item counter only counts actually totaled transactions The item counter is incre...

Page 177: ...e totaling memory by sequentially pressing the key and F6 Plus key The item list begins with the latest entry Page through the list with the F3 older entries and F4 newer entries Arrow keys The last 50 entries can be retrieved Press the F5 Back key to close the display of the individual items and to return to the previous screen Info Display information field with item list Last Item can be progra...

Page 178: ...ored in the totaling memory item list The individual items can be retrieved with the Arrow keys F3 F4 Tare key Displays the current tare weight in tare memory Press the key after pressing the key 6 13 9 Save the current values to fixed memory In order to save output and input functions IO Port directly to fixed memory start by entering the output and input functions Pressing the F5 Enter Fix key i...

Page 179: ...gs in setup mode The parameters in setup mode allow you to customize the application program Dynamic Switching to your specific needs Start setup mode by pressing the F6 Setup Mode key in the settings function level and from there press F6 Save to start Program Settings F6 Next retrieves the program settings for the highlighted application program 9 Dynamic switching Target value comparison Choice...

Page 180: ... assigned to the Total key Only display totals The total is displayed after the Total function key is pressed The user can then decide whether to delete the totaling memory Press the F2 Delete Total key to delete the totaling memory Then confirm the security question with YES using the F1 to F3 keys this is followed by the total printout Display print and delete total After pressing the Total func...

Page 181: ...ct whether fixed values are retrieved with sequential memory location numbers or part numbers Factory default Part number Delete fixed switching values Select do not execute or execute Execute deletes all fixed neutral measurement values Start mode Select off or on If start mode is enabled the scale freezes the value after reaching the respectively enabled switching points S1 to S6 and as a result...

Page 182: ...ion keys The function keys F1 to F6 are available to control the functions These are assigned in four levels switching between the levels is accomplished with the Function Page key 1 Level Percent functions Perc 100 Perc Variab Del Perc Total Cancel Add F 1 F 2 F 3 F 4 F 5 F 6 2 Level Control functions Perc Contr Start F 1 F 2 F 3 F 4 F 5 F 6 3 Level Tare functions Tare Fix Add Tare Int Tare Multi...

Page 183: ...l secondary display e g to additionally display the current weight or the tare weight The setting to determine what value is shown in the secondary display is made in setup mode under Setup Mode Terminal Display Secondary Display Figure Secondary display with current weight ...

Page 184: ...e indicator light function Total continuous display of totaling memory Last item Continuous display of the last item Organization data database Continuous display of the organization data memories Display barcode Continuous display of the scanned barcode Example information field display setting to total Example the control display shows an indicator light in the information field 1 Below toleranc...

Page 185: ... The scale has saved the reference weight and displays the entered percentage value Additionally placed material is continuously displayed as a percentage value in relation to the reference part Function key F3 Del Perc Pressing the F3 Del Perc key or the key deletes the current reference weight The scale ends the percent weighing function and returns to the weight display Weight display during pe...

Page 186: ...being removed from the scale The measurement location cannot be changed during the picking transaction The selection between totaling or picking is made in setup mode Program Settings The selection applies to all subsequent weighing bridges For purposes of the description the following only addresses totaling Totaling memory with several connected scales A central totaling memory is maintained for...

Page 187: ...l number is entered the weight value on the scale is saved by pressing the F6 key The error message Error 46 is displayed if the scale is not under load Cancellations or reverse weighings are marked in the printed receipt as Cancellation A cancellation causes the sequential number to be incremented by one while the item counter is decremented by one If the item counter is 0 no further cancellation...

Page 188: ...s a condition that triggers a printout see Section 8 Printing Assigning and deleting the sequential number Every entry plus manual cancel into the totaling memory is assigned a 4 digit sequential number The sequential number is not reset in the factory default condition Resetting the sequential number can be optionally programmed in setup mode disabled no reset factory default on Delete Total key ...

Page 189: ... list begins with the latest entry Page through the list with the F3 older entries and F4 newer entries Arrow keys The last 50 entries can be retrieved Press the F6 Back key to close the display of the individual items and to return to the previous screen Totaling outside of tolerance Totaling quantities outside of a specified tolerance range can be prevented If the unit count is outside of the to...

Page 190: ...the factory default or indicator light function is enabled in the info field The appropriate indicator light color with special character is displayed to match the current status of the scale to target value Control state Indicator light color Special character Below tolerance limit yellow In tolerance green Exact target value reached green Above tolerance limit red You can also display the differ...

Page 191: ...disabling the switching point and thus without unintentionally starting a new transaction The frozen state is only lifted by pressing the F6 Start key in the Control Functions level Enable the start mode in setup mode under Program Settings Percent Weighing Start Mode End controlling Press the key to start the 2nd Control Functions level and press the F5 Quantity Contr key then delete with the F2 ...

Page 192: ...Select within or outside This parameter specifies whether a data record is transmitted to the printer or IT only within the tolerance or also outside of the tolerance If a data record is also accepted outside of the tolerance it is then marked with a special character Factory default outside Totaling outside of tolerance Select within or outside This parameter specifies whether totaling into total...

Page 193: ...ight is displayed Between 0 and 30 number increments can be specified On 0 totaling is possible as long as the scale has not settled once Factory default 15 number increments IO assignments Select do not execute or execute Execute enables the switching function for an external control light or control An I O card must be installed to control the switching processes Start mode Select off or on If s...

Page 194: ...the following essentially equivalent text Readings from user programmable accessory equipment The calibrated readings are available for review 7 1 1 Enable alibi memory The alibi memory is enabled in the service area Please contact your Soehnle Industrial Solutions service partner The symbol is enabled in the symbol bar when the alibi memory is enabled The symbol additionally shows information abo...

Page 195: ...e entry has the following format A sequential number of the entry Scale type serial number Measurement location number Gross weight Tare weight Example A0000123 2813 04 0002 01 AG 150 g AT 25 g The F1 key triggers a single printout the F5 key returns to the Alibi Memory menu Find function several entries Retrieves several sequential entries which are delimited by entering the latest and the oldest...

Page 196: ...or date time Display in alibi memory The add on field is displayed directly under gross and tare value left aligned The printed output is formatted as follows A0000170 2889 15 9998 01 AG 0 309 kg AT 0 000 kg 12345678901234567890123456789012345 Saving add on field data The data link with the alibi memory is programmed in Setup Mode Communication Alibi Memory Highlight Add on Field Use with the F4 A...

Page 197: ...emory Org Data A expands the current content from Org Data Memory A Org Data B expands the current content from Org Data Memory B Org Data C expands the current content from Org Data Memory C Org Data D expands the current content from Org Data Memory D Date Time expands the current date time from the terminal 3035 7 1 4 Delete and disable alibi memory The alibi memory is deleted and disabled in t...

Page 198: ...e is disabled 2795 14 Soehnle Professional Receipt Printer Printer Port 1 2795 12 2795 20 Soehnle Professional Label Printer Printer Port 2 IT bi directional function Terminal can send and receive data IT Port IT2 uni directional function Terminal can only send but not receive data IT Port uni Barcode for scanner connection data input for barcode processing memory Secondary large display for using...

Page 199: ...ce is disabled 2795 14 Soehnle Professional Receipt Printer Printer Port 1 2795 12 2795 20 Soehnle Professional Label Printer Printer Port 2 IT bi directional function Terminal can send and receive data IT Port IT2 uni directional function Terminal can only send not receive data IT Port uni Barcode for scanner connection data input for barcode processing memory Secondary large display for using So...

Page 200: ...nfiguration of Port 3 starts at this line item Use of interface None no use and interface is disabled 2795 14 Soehnle Professional Receipt Printer Printer Port 1 2795 12 2795 20 Soehnle Professional Label Printer Printer Port 2 IT bi directional function Terminal can send and receive data IT Port IT2 uni directional function Terminal can only send not receive data IT Port uni Barcode for scanner c...

Page 201: ...all interfaces 7 5 USB The hardware for the RS 232 internal Interface 1 is mounted on the motherboard Depending on the terminal configuration the interface is routed externally with a 4 pin socket A special connection cable is required depending on how the interface is used Contact your dealer or a Soehnle Industrial Solutions service partner with any related questions Programming parameters Start...

Page 202: ...erface and closing setup mode The display goes dark briefly Factory default IT for version 3035 01 002 with USB interface or on Reset Terminal 7 5 1 Data logger Use of the data logger requires a USB interface and the data cable 2550 03 027 Set the USB port use to data logger Then insert the USB stick into the data cable socket When a USB stick USB 2 0 or lower is inserted the LOG flag is displayed...

Page 203: ...ent USB sticks must not be used during the logging process When the stick needs to be changed switch off the terminal remove the stick and insert the new stick Then turn the terminal back on Example contents of a log file with alibi memory Start 22 12 15 12 55 52 N 1 365 kg A0000168 22 12 15 12 58 21 N 0 539 kg A0000169 22 12 15 12 59 43 N 15 872 kg A0000170 End 7 6 Ethernet The hardware for the E...

Page 204: ... for printouts are configured under Print Format Programming parameters Start setup mode with F6 key in the Setup Functions key level Highlight Communication with the F4 Arrow key F6 Next Highlight Print Format with the F4 Arrow key F6 Next The parameter configuration Print Format starts at this line item Query Printout OK Off On When on a query asks after each printout whether the printout was OK...

Page 205: ...default 0 Delete value after printout For applications with security aspects the function can automatically delete certain data fields following a hardcopy or IT output Up to 10 data fields can be customized for automatic deletion via the print code Details and settings for the print code can be found in the interface description 470 508 090 Factory default Do not execute Execute Execute resets al...

Page 206: ...n 470 508 090 with the service software Factory default IT print format variable IT data record autom I Off On For On the IT interface automatically transmits the data record with the print format via the IT interface after each settle The Service software is required to design the print format layout Factory default off IT mode uni directional no sending of data record A send data record 1 x imme...

Page 207: ...t execute Execute Execute resets all custom settings in this parameter area back to factory defaults 7 9 Anybus The parameters for the optional bus interface on the Anybus slot are configured under Anybus The Profibus DP and ProfiNet interface versions are currently available function execution is currently still pending to follow in subsequent revision Programming parameters Start setup mode with...

Page 208: ...in in the data record or as a printed receipt In addition weight readings and unit counts determined by the scale can also be printed as encoded barcodes Your Soehnle Industrial Solutions service partner can set up your IT data record or the layout of the barcode printing 7 10 1 Decimal delimiter numeric Data fields enabled as numeric in the service program can be programmed in conjunction with th...

Page 209: ...Functions key level Highlight Communication with the F4 Arrow key F6 Next Highlight Barcode with the F4 Arrow key F6 Next Highlight Barcode Timer with the F4 Arrow key F6 Next Enter the time for displaying the currently received scanner content with the number keypad in milliseconds The function is disabled by entering the value 0 The entered value can range from 1 to 9999 milliseconds By pressing...

Page 210: ...e barcode is permanently displayed in the information field for the relevant application program 7 10 3 Barcode selection filter Up to 10 different selection filters can be set for downstream processing After the filter number has been defined the control code must be set followed by the first position and the last position of the relevant filter The filter application must always start with filte...

Page 211: ... Highlight Barcode with the F4 Arrow key F6 Next Highlight Selection filtering no with the F4 Arrow key F6 Next The parameter configuration for all barcode filter functions starts at this line item Select filter No 01 Press F6 Next to enter the filter No Enter the filter No s starting with number 01 and rising up to No 10 then save with F6 Save ...

Page 212: ... to 3 characters The factor default for all parameters is 0 By pressing the F6 key the entered value is saved and the display returns to the Barcode setup menu The control code assignments can be found in the description 470 509 090 Data Interface 3035 The start position is specified after the control code filter No ex 01 has been entered Enter the first position and then press F6 Save Factory def...

Page 213: ...ting and output Weight readings and unit counts determined by the scale can be printed as barcodes Scanned barcodes are printed as scanned The print format must first be enabled before barcodes can be printed The following print formats with barcode functions are supplied as factory defaults Print format No 02 Barcode 2795 12 Sample Barcode Code 128 to printer port 2795 12 2795 20 Print format No ...

Page 214: ... level Highlight Communication with the F4 Arrow key F6 Next Highlight IO control with the F4 Arrow key F6 Next Highlight IO mode with the F4 Arrow key F6 Next The relevant function is enabled after the selection and pressing the F6 Save key IO operating mode off Switching output and input functions are disabled Factory default off IO operating mode on Switching output and input functions are enab...

Page 215: ...elevant process dependent state The IO control is set to Off if enabling is rejected with NO with the F4 to F6 Function keys The inputs outputs are only reenabled by resetting the IO control to On or On With Safety Function in setup mode 7 11 2 Outputs Output settings Start setup mode with F6 key in the Setup Functions key level Highlight Communication with the F4 Arrow key F6 Next Highlight IO Co...

Page 216: ...nd F4 Arrow keys F6 Edit retrieves the highlighted switching point A list of available switching conditions is generated for the retrieved switching point S1 You can move around in the list with the F3 and F4 Arrow keys Pressing F6 Save saves the S1 switching condition for instance a weight reading is saved as a switching condition for a target value ...

Page 217: ...ing the value 0 The entered value is saved with the F6 key Saving the switching lag is followed by the selection window for the polarity When Normal is selected the switching signal goes from Low to High when the required condition is met whereas the switching signal goes from High to Low when the required condition is met when Inverted is selected Highlight with F3 and F4 Arrow keys and save the ...

Page 218: ...ow keys and save the setting with F6 Saving the lockout is followed by the output overview unless the selected switching condition is the target value in this case the next window is the selection window for the Weight Reading switching point When Net is selected the switching function depends on the net weight whereas the enabled switching function depends on the gross weight reading when Gross i...

Page 219: ...as been saved the display returns to the Output menu window with the list for editing function conditions for the outputs S1 to S6 The menu window displays the switching point S1 for enabled conditions switching lag timer T polarity inverted I lockout V and net N the switching point of the weight value is also always displayed Repeat the procedure for all other switching points to be assigned Once...

Page 220: ...ation field until the scale is again relieved Delete outputs All conditions can now be deleted with the F2 Delete key or the key The deletion is effective immediately and the display continues to the IO Control menu Function options for assigning outputs disabled settle Empty message underload overload Target value scale ready Weight reading below toler Weight reading above toler Weight reading wi...

Page 221: ...h the F4 Arrow key F6 Next Highlight IO Control with the F4 Arrow key F6 Next Highlight Inputs with the F4 Arrow key F6 Next Assign inputs Menu window with the list for editing the function assignments for inputs E1 to E4 You can move around in the list with the F3 and F4 Arrow keys F6 Edit retrieves the highlighted input ...

Page 222: ...with F6 Saving is followed by the data entry field for the signal flank The rising signal flank LH selection enables the input switching signal as the flank goes from Low to High whereas the input switching signal is enabled from High to Low for the falling flank HL Highlight the selection with the F3 and F4 Arrow keys and save the setting with F6 ...

Page 223: ...th F1 End In weighing mode the information field displays the inputs for the Dynamic Switching application program assigned inputs have dark backlighting A fixed display of the switching condition in the information field can be programmed in setup mode under Program Setting for each application program with IO control A totaling transaction or the retrieval of the organization data memory interru...

Page 224: ...ons for assigning inputs disabled Switching off Tare Delete tare Zero reset Request data record B Complete keypad lock Measurement location switch Add Total Start Print key Enter key Block data record Blocking function ...

Page 225: ...keys can be assigned with the 30xx Print Formats service software The following print formats are already included and assigned in the factory defaults and can therefore be printed These standard print formats for the 2795 14 printer are examples and show what parameters are available Program Weighing and tare Print format No 01 Name Standard Printout trigger Print key Program Totaling picking Pri...

Page 226: ...2 15 Time 9 23 15 AM Scale No 02 Gross G 0 694 kg Tare T 0 016 kg Net N 0 678 kg Reference unit count 10 pcs Reference weight 12 2700 g Unit count 55 pcs Date 31 12 15 Time 10 49 49 AM Scale No 02 Gross G 0 183 kg Tare T 0 030 kg Net N 0 153 kg Target value 0 154 kg Minus tolerance 0 005 kg Plus tolerance 0 005 kg Deviation 0 001 kg Date 31 12 15 Time 10 53 10 AM Scale No 02 Gross G 0 282 kg Tare ...

Page 227: ...ts in container 03 Gross container total 0 359 kg Tare container total 0 108 kg Net container total 0 251 kg Total container count 02 Components in all containers 0007 Gross total 0 968 kg Tare total 0 216 kg Date 31 12 15 Time 12 23 15 PM Scale No 02 Gross G 0 243 kg Tare T 0 096 kg Net N 0 147 kg Specific weight 73 4100 g Quantity Date 31 12 15 Time 12 33 21 PM Motor vehicle registration BK SP 6...

Page 228: ... 12 15 Time 12 55 43 PM Scale No 02 Gross G 4 240 kg Tare T 3 120 kg Net N 1 120 kg Switching point 1 0 1 kg Switching point 2 0 2 kg Switching point 3 0 3 kg Switching point 4 0 4 kg Date 31 12 15 Time 2 28 52 PM Scale No 01 Gross G 3 200 kg Tare T 0 000 kg Net N 3 200 kg Percentage 170 1 Date 31 12 15 Time 12 42 23 PM Alibi memory Nr A0000172 Motor vehicle registration BK SP 6000 Gross weight 32...

Page 229: ...001 Printout trigger enabled with Info Print This standard print format for the 2795 20 label printer is an example and shows what parameters are available Print format No 04 Name Label 2795 20 001 Printout trigger enabled with Info Print Gross weight G 0 154 kg Tare weight T 0 100 kg 31 12 15 12 55 43 OrgA Name OrgA Content Gross G 0 220 kg Tare T 0 066 kg Net N 0 154 kg 31 12 15 12 55 43 OrgA Na...

Page 230: ...d with Info Print 6 digit value w o unit of measure Print format No 11 Name Data logger Trigger enabled with Info Print data is tab delimited end with CR LF See interface description 470 508 090 for more details about standard print formats Reset standard print formats factory defaults In order to reset all terminal print formats back to the factory defaults the terminal can be reset in settings m...

Page 231: ...ter release of small empty message E Send continuous F Enter key on release from ORG A Enter key on release from ORG B Enter key on release from ORG C Enter key on release from ORG D Plus key Enter Save key on manual entry Enter Save key on cancel Total key depending on setting Container key container close out Enter Save key on first weighing see details under 6 12 3 Functions Vehicle scale Enter...

Page 232: ...baud rate data bits parity and Xon Xoff according to the details in the printer manual The parameters for Soehnle Professional printers are included in the factory defaults 8 4 Quick change of print formats If the scale operator is to be given the ability to make on demand print format switches directly at the terminal e g because a print format is needed in several languages during the course of ...

Page 233: ...easurement location defective 12 not assigned 13 not assigned 14 no measurement location Measurement location disabled or defective 15 not assigned 16 not assigned 17 no free reference value All 4 adjustment reference points are assigned 18 not assigned 19 not assigned 20 Print format empty No print format content stored generate print format 21 not assigned 22 not assigned 23 Print failed Printer...

Page 234: ...tems entered Cancel not possible because totaling memory has no items 49 Total memory overflow Value in totaling memory too high delete memory 50 Value below zero reset limit Reading below stored zero point scale has mechanical damage place preload readjust replace load cell 51 Value above zero reset limit Weight reading above stored zero point scale has mechanical damage remove preload readjust r...

Page 235: ... adjustment check shielded cable increase settle window 74 not assigned 75 Replace buffer battery Replace battery 76 not assigned 77 not assigned 78 not assigned 79 not assigned 80 Cancel external command Incorrect data format for command check command resend 81 Timeout external command Lag time for initiated command exceeded settle not achieved during adjustment check shielded cable increase sett...

Page 236: ...er the retrieval is shown Error list content Line item of the error list Date time of last error Error number and count of the error message Text description of the error message Use the F3 and F4 keys to page through the error list Close the error list with F5 Back The error list can record up to 50 errors 9 3 Mirco SD card The Soehnle Professional Micro SD card high quality SLC memory card is an...

Page 237: ...be updated by the factory The current software revision can be retrieved in Setup Mode Terminal Revision Bootloader Software LRS software The LRS software can only be updated by the factory The current software revision can be retrieved in Setup Mode Terminal Revision LRS Software AZG The terminal should be reset after the software update has been completed Detailed information about resetting the...

Page 238: ...ction is disabled when the file is full 9 5 Supplemental documentation Program settings See the separate technical documentation 470 702 113 for more information about software settings Setup mode UCAL See the separate technical documentation 470 702 112 for more information about setup mode UCAL Programming ECAL See the separate technical documentation 470 702 110 for more information about progr...

Page 239: ...239 ...

Page 240: ...Soehnle Industrial Solutions GmbH Gaildorfer Straße 6 DE 71522 Backnang Telephone 49 71 91 34 53 220 Fax 49 71 91 34 53 211 info soehnle professional com www soehnle professional com ...

Reviews: