188
Relief factor when totaling
(cannot be enabled for picking)
You can specify in setup mode that the scale must be relieved by a certain number of number
increments between placing individual items
If the scale is not relieved, the weight value is not saved to the totaling memory, and the error
message "Error 55 - Place Weight" is issued. This for instance prevents saving an item twice.
Auto totaling
The Auto Totaling function can be enabled in setup mode.
In this case, only the first item must be saved with the Plus key, all other items are automatically
saved to the totaling memory after the scale is loaded and settles.
The Plus key remains hidden as long as auto totaling is enabled.
If auto totaling is terminated with cancel, error message or change of measurement location,
auto totaling must be restarted with the Plus key.
Info: Just like manual totaling, auto totaling can be defined as a condition that triggers a printout
(see Section 8 Printing).
Assigning and deleting the sequential number
Every entry (plus, manual, cancel) into the totaling memory is assigned a 4-digit sequential number.
The sequential number is not reset in the factory default condition.
Resetting the sequential number can be optionally programmed in setup mode:
•
disabled (no reset = factory default)
•
on Delete Total key
•
on switch off
•
function key "Delete Seq. Number"
Item counter
The item counter only counts actually totaled transactions. The item counter is incremented by 1
for each new transaction with plus, manual, or automatic totaling. The item counter counts to 999;
this is followed by an error message. The item counter is decremented by 1 for a cancellation.
The item counter is automatically reset to zero when the total is deleted.
Keys that trigger printouts
The Plus, Cancel, and Total keys can trigger a receipt printout.
A prerequisite for this is that the relevant key has a print format assigned.
The option "Display, print and delete" must be selected for the Total key in setup mode Total key
function.