39
5.5 Tare function
Tare is the difference between gross and net weights
A detailed description for tare is found in the application program Weighing and Tare, Section 6.5
on page 57.
5.6 Gross display
Displays the gross weight with tared scale
Use the Function Page key to switch to the setup functions level.
Gross
x 10
Secondary
display
Prog
ram
Setup
mode
F 1
F 2
F 3
F 4
F 5
F 6
Press the F1 Gross key.
While the key is pressed and held, the display shows the gross weight with the Gross reference.
5.7 Scale switching
Switching between several connected scales.
Up to three analog measurement locations can be installed, and a total of up to 29 measurement
locations can be connected in the display unit 3035. A digital scale can also be connected with the
RS 232 interface as measurement location No. 30. Switching between connected measurement
locations is accomplished manually or automatically.
Manual switching:
Briefly press the key. The connected measurement locations are sequentially queried.
Press and hold the key.
A data entry field opens and the measurement location No. can be entered and saved directly.
Automatic switching: See description for Counting program in Section 6.7.9.
The display shows the number of the queried measurement location in the symbol bar on the right.
Press Info to display the data for the queried measurement location. Press the key combination Info
/ Scale Switching to sequentially see the data for other connected measurement locations.
The following data is displayed:
•
Max, Min, e (d)
•
Serial No. of measurement location (additionally when enabled)
•
Calibration counter
•
Ident chip (additionally when enabled)