82
a) Retrieving the Ref Fix memory to edit the counted parts:
Press the key and then F2 Ref Fix
Selecting available fixed values from the list
Page with the F3 or F4 Arrow keys until you have reached the desired memory location; enter the
desired fixed value with F6 Edit.
Direct retrieval with memory location number or part number. Use the number keypad to enter the
part or memory location number. The specification whether the part or memory location number is
retrieved is made in setup mode. The part number is entered as a left aligned search criterion; the
memory location number is entered as a right aligned search criterion Enter the desired fixed value
with F6 Edit
Edit an existing fixed value from the list
Edit the highlighted fixed value with F6 Edit.
Parameter name is highlighted; retrieve with F6 Edit, enter with keypad. Save the entry with F6
(cancel without saving the entry with F5 Cancel).
Other parameters are edited in the same manner.
Deleting an existing fixed value
Page with the F3 and F4 Arrow keys or retrieve with the part number or the sequential number.
Delete the retrieved fixed value with F2 Delete. Respond YES to the security question.
The resulting gap in the sequential numbering will be closed.
Save new fixed value
Press F1 New.
The memory location number is assigned by the equipment. The first number in parenthesis
indicates the free memory locations, the second number indicates the assigned memory locations.
Parameter name is highlighted; retrieve with F6 Edit, enter with keypad. Save the entry with F6
(cancel without saving the entry with F5 Cancel).
Other parameters are edited in the same manner.
Closing the fixed value list
The list is closed with the F5 Back key.
b) Retrieving the reference weight list for counting
Press the F4 Ref Fix key in the Control Function level 2.
The display now shows the last retrieved fixed value.
Select from the list
•
Page with the F3 or F4 Arrow keys until you have reached the desired memory location;
enter the desired fixed value with F6 Save.
•
Direct retrieval with part number or storage location number
Use the number keypad to enter the part or storage location number.
(the rule to either retrieve the part or storage location number is specified in setup mode,
with the part number entered as a left-aligned search criterion; the storage location
number is entered as a right-aligned search criterion) the desired fixed value is saved with
F6 Save.